Safety pipe
rura bezpieczeństwa
rura przelewowa (do kanalizacji) K
Overflow pipe
Water supply
pipe
Power supply
Fig. 4.
b) Closed (pressure) system
The Unico Nemo fireplace insert with a water jacket can be
used in closed heating systems as an independent or
supporting heating source. The installation should be made
and secured in accordance with the requirements of PN-EN
13229/A1:2005, 13229/A2:2006.
The maximum pressure in the installation system should
be 1,9 bar.
A diaphragm expansion vessel should be used.
The insert should be secured by a 2.0 bar safety valve.
The Unico Nemo fireplace insert should be equipped
with a water jacket cooler (coil) and a thermostatic
safety valve.
NOTE:
a)
In order to facilitate installation, Unico Nemo fireplace
inserts are equipped with connections for installation on
both the right and left side of the body.
b)
It is recommended to install fireplace insert accessories,
such as pump, valves, heat exchanger, expansion
vessel, etc., so that they are visible and easily
accessible.
Controller
Controller sensor
Expansion pipe
CH pump
CH return
Fig. 5.

4.7. Notes on the first start-up

5. User manual

5.1. Fuel

• The fireplace is designed for burning natural wood with
Water supply
Power supply
pipe
Controller sensor
CH pump
1.Safety valve
2. Thermal relief
The first start-up of the insert must be made before
installing the fireplace.
After the first usage of the insert, a check should be
made whether the central heating installation is filled
with water.
If there is a risk of temporary temperature drop below
0°C, the central heating installation should be filled with
anti-freeze liquid.
The use of corrosion inhibitors is recommended.
During the first few hours of burning, the varnish
coating is burned out and, as a consequence, there
might be a specific, often unpleasant smell.
Before the first use, the gaskets (in the upper part
of the chamber) used for protection during transport
must be removed.
humidity not exceeding 20%.
Controller
To sewage system
Diaphragm vessel
CH return
8