Page 2
In order to make the most of the technical parameters of the Unico insert, as well as to ensure perfect safety during its use, we kindly ask you to read carefully and follow the instructions in this manual.
General information and recommendations Compliance with standards and regulations Safety recommendations Insert installation manual Fire protection 4.1. Ventilation 4.2. 4.3. Combustion air supply 4.4. Heating air circulation Chimney 4.5. 4.6. Connecting the Nemo insert to the central heating system 4.7. Notes on the first start-up User manual 5.1.
• The Unico insert is designed to work only with its door closed. Using the insert with the door open is prohibited. 1. General information and recommendations • During operation of the device, all its components are heated, so any maintenance works should be carried The Unico Dragon fireplace insert is designed and out with the use of protective gloves.
The minimum distances to be kept for the min. 50 mm thick. foundation and installation of the Unico fireplace insert are After mounting, the insert should be levelled with shown in Figure 1 and Table 1.
It is absolutely necessary to provide sufficient combustion upper part of the housing) must be 40% larger than the air to the fireplace insert. In Unico inserts, this is done from surface of the inlet, assuming that the fireplace is used with outside the room through a suction unit.
4.6. Connecting the Nemo insert to the central heating system Fireplace inserts Unico with a water jacket can be used in gravity or pump heating open systems as an independent or supporting heating source. The installation should be decompression chamber...
4.7. Notes on the first start-up • The first start-up of the insert must be made before The Unico Nemo fireplace insert with a water jacket can be used in closed heating systems as an independent or installing the fireplace.
(preferably rolls of wood wool soaked in paraffin) should be put on top of the pile and lit from the top, which is the recommended method for Unico inserts, making burning cleaner with less smoke emission, which, in turn, makes the whole process more ecological and efficient.
Wall surfaces inside the combustion chamber should be cleaned using a soft brush, and if there is soot - a spatula. The fireplace glass should be cleaned with a special Unico sponge - the material that the sponge is made from can remove the most stubborn soot dirt.
Before the start of the heating season, a comprehensive inspection of the insert should be performed and the following points should be checked: • any blockages and tightness of the ducts supplying combustion air, cleanliness of the chimney and its connections, •...