General Performance Specifications; Typical Indexing Performance - Camco VARI-PAK Installation And Operating Instructions Manual

Cycling dc motor control
Table of Contents

Advertisement

TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONS
Parameter
(Units)
AC Line Input
(VAC ± 10%, 50/60 Hz)
Horsepower Range HP, (kW)
Armature Voltage Range (VDC)
Current Ranges (ADC)
CL Trimpot Range
(% Range Setting)
MIN Speed Trimpot Range
(% Base Speed)
MAX Speed Trimpot Range
(% Base Speed)
IR COMP Trimpot Range
(% Base Speed)
Speed Range (Ratio)
AC Line Voltage Regulation
(% Base Speed)
Voltage Following Linearity
(% Base Speed)
Load Regulation
(% Base Speed)
Ambient Temperature Range (ºC)
Potentiometer, Front Cover
(ohms – watts)
Maximum Run/Stop Operations
(ops/min)
Enclosure Type (NEMA)
FIGURE 1 – TYPICAL INDEXING PERFORMANCE
SPEED
(rpm)
1800
FIXED
ACCEL
100
4
Specifications
Part Nos.
92A61633010000
92A61633020000
115
1/6 – 1, (0.12 – 0.75)
0 – 100
2, 3.3, 5, 10
0 – 170
0 – 30
60 – 120
0 – 15
50:1
± 0.5
± 0.5
± 1
0 – 45
5K – 1/3
30
12
MOTOR BASE RATED SPEED
TIME (msec)
Specifications
Part Nos.
Factory
92A61633030000
Setting
92A61633040000
208/230
1/3, (0.25)
1/3 – 2, (0.25 – 1.5)
85
0 – 200
3.3
2, 3.3, 5, 10
150
0 – 170
0
0 – 30
100
60 – 120
4
0 – 30
50:1
± 0.5
± 0.5
± 1
0 – 45
5K – 1/3
30
12
Maximum Cycle
Rate: 30 cycles
per minute with
typical 1 HP motor.
Total reflected
inertia not to
exceed 20% of
armature inertia.
Acceleration time
(fixed at 0.1 sec.)
DECEL WITH
may be extended
DYNAMIC BRAKE
when operating in
Current LImit
250
Factory
Setting
1/4, (0.18)
170
2
150
0
100
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents