Section I / Unit Components - Page: 3
Section II / Description
Section III / Assembly and Installation - Page: 4-6
Section IV / Operational Safeguards - Page: 6
Section V / System Operation - Page: 7-9
Section VI / Built In Safeguards - Page: 9-10
Section VII / Application Requirements - Page: 10-11
Section VIII / Maintenance - Page: 11
Section IX / Utilizing Your KBA& KBAPlus System - Page: 11
Section X / Fault Codes - Page 12
Section XI / KBA& KBAPlus Troubleshooting Guide - Page: 12-15
Appendix:
Part A: HEPA Filter PartB: Ultra Violet Light
Part C: Charcoal Filter
Before installing and using your KwiKool Bio Air (KBA) or KwiKool Bio Air Plus (KBAP) system, read this
manual carefully for instructions and proper usage and all safeguards. This manual should be retained for
future reference.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Bio Air Series and is the answer not in the manual?

Questions and answers

Summary of Contents for KwiKool Bio Air Series

  • Page 1 Part A: HEPA Filter PartB: Ultra Violet Light Part C: Charcoal Filter Before installing and using your KwiKool Bio Air (KBA) or KwiKool Bio Air Plus (KBAP) system, read this manual carefully for instructions and proper usage and all safeguards. This manual should be retained for...
  • Page 2 I / Unit Components. KBA Plus KBA Control KBA Plus Control II / Description A. Bio Air KBA series is designed as an attractive stand-alone negative air machine. It comes equipped with a duct collar designed to attachto the top of your BIOAIR. The sizeof the collar for a 600 model is an 8”...
  • Page 3 III / Assembly and Installation- A. KBA600 and KBA1000Arrive from the factory ready to operate after it is removed from the packing. Only attachment of the collar, optional ceiling kit or user supplied ducting is required. B. KBA600P and KBA1000P users will need to remove one or both cover plateson the supply air before operatingand/or install the duct collar to the top of the unit.
  • Page 4 Do not touch your system with wet hands. D. To insure your KwiKool Bio Air system is stable, the floor on which the system is to be place should be level, free of vibration and strong enough to support the weight of your model.
  • Page 5 J. If your KwiKool Bio Air system makes abnormal noises or vibrations, call KwiKool at 1-800-594-5665. V / System Operation KBA Plus Only A. Select your KBAPlus operational function; before using your system, choose the operation you would like your system to perform.
  • Page 6 the filtered air back into your space. For odor control order the optional charcoal filter with your KBA system. 2. KBA system can be configured to remove air from a sealed space, creating a negative pressure in the space to allow for fresh air to be exchanged with the ambient air, the filtered air discharged is directed out of the space.
  • Page 7: User Parameter Settings

    . USER PARAMETER SETTINGS - Entrance into this function is gained by a Short press on the “Settings” button .NOTE; A 5 second press on this button changes the display to F or C temperature display. Use the FAN and Mode buttons to scroll through the available parameters 5.
  • Page 8 UV light operation, the lights are automatically operational when ON is selected. 2. Turn On your KwiKool Bio Air system KBA-Select the ON position with the lighted ON/OFF rocker switch and your system will begin to operate. The supply air fan starts in the chosen fan speed.
  • Page 9 E. Locking casters-To prevent un-intended movement of the system, locking casters are installed on the front of all KwiKool Bio Air systems. Move the system to a level surface and move the locks on the casters to the ON position.Move to OFF when moving the system.
  • Page 10 For best results replace both UV bulbs at the same time to ensure the most efficient operation of your KwiKool Bio Air PlusUnplug the UVC bulb - With one hand holding the plug and the other holding thewhite end cap of the bulb in place, pull the two apart.Remove the bulb from your system - Reach inside the unit and pull the bulb out ofits retaining clips from the middle of the bulb.
  • Page 11 X / Fault Codes KBA Plus Only Your KwiKool Bio Air Plus System displays a fault code to indicate that maintenance is needed on your system; the nature of themaintenance is displayed on the touchscreen panel. See the troubleshooting guide later in this manual for further information.
  • Page 12 FIL = 90 days of operation have passed with the currently installed filters.(Factory setting, may be modified by administrators). A1 = Customer installed device on the KBA Plus systemis activated (if equipped) F1 = System is being operated in an ambient temperature below 28 degrees F. XI / KBAP and KBA Troubleshooting Guide Fault on KBAP Control Control displays UL, on start up or while operating, AL blinks on control, system continues to operate.
  • Page 13 Power circuit is not engaged, system is not plugged in. Possible Solution Check source power breaker and verify incoming power to connector, plug the system into the proper outlet. Call 1-800-KWIKOOL for assistance. Fault System trips breaker on start up...
  • Page 14 Possible Solution Confirm HEPA filter is installed and activating the safety switch, refer to the maintenance section for bulb replacement steps, confirm your system is equipped with UV lights, call 800-KWIKOOL if switch is depressed and not activating the UV lights.