Figure 13: Sleepclock signal
No RX (no rx calibration...RSSI reading fixed value)
MAD / COBBA / R263 faulty
Check if the 13MHz IF frequency on pin 22,23 COBBA change the amplitude if the generator frequency level
are change
Check if the RXC impulse on pin 36 N600 (SUMMA) change the amplitude if the generator frequency level
are change
Check R263 if any or low signal are measurable
Change MAD
Change COBBA (Think about SIM-LOC data and new update after change it)
No RX (no rx calibration...RSSI reading high difference)
Z560 Duplexer faulty / poor soldering
Check the rx signal on the ANT pin and on the out going pins RX-G or RX-D
Check that the signal attenuation between duplexer "in" and "out" is around 2dbm-5dbm depending on the
receiver band
Resolder the duplexer or change it
No RX (no rx calibration...RSSI reading highest value)
Z600 / Z601 faulty / poor soldering
Check the 73MHz IF frequency on Z600
Check the components C511, C512, L503, L504 if the signal amplitude is different between the two lines
check the soldering of Z600 or change it
check the 13MHz IF frequency on Z601, around 3dbm attenuation between signal-in and signal-out
check the soldering of Z601 or change it