Advertisement

Quick Links

EN
MAINTENANCE MANUAL
WARRANTY CARD
luna 200
AIR HANDLING UNIT
Below documentation shall be kept by user!
In case of not following the conditions of this document, the warranty expires.
dospel@dospel.com
www.dospel.com
+48 (34) 370 30 00
facebook.com/Dospel.Wentylacja
twitter.com/dospel_com
snapchat: dospel.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the luna 200 and is the answer not in the manual?

Questions and answers

Summary of Contents for DOSPEL luna 200

  • Page 1 MAINTENANCE MANUAL WARRANTY CARD luna 200 AIR HANDLING UNIT Below documentation shall be kept by user! In case of not following the conditions of this document, the warranty expires. dospel@dospel.com www.dospel.com +48 (34) 370 30 00 facebook.com/Dospel.Wentylacja twitter.com/dospel_com snapchat: dospel.com...
  • Page 2: Table Of Contents

    1. GENERAL INFORMATION........1.1. Purpose............1.2. Technical specification........2. ASSEMBLY............2.1. Required exploitation conditions......2.2. Assembly of siphon out condensate..... 2.3. Connecting to power grid......... 3. STARTING THE UNIT.......... 3.1. General remarks..........3.2. Starting the unit..........3.3. Summer mode..........3.4. Exploitation recommendation......3.5.
  • Page 3: General Information

    1. BASIC INFORMATION 1.1 Purpose Luna 200 air handling unit is designed to assure air exchange in residential buildings. The unit's puprose it to supply fresh air from the outside and dispose used air from the rooms with simultaneous recovery of thermal energy. As standard, the unit is equipped with with bypass which can be switched on without opening the casing.
  • Page 4 WARNING! Luna 200 should be lifted by holding the casing. It is forbidden to lift by holding the connectors. It may result in leakage and damage to the device. 1108 Fig.1. Nominal dimensions LUNA 200 Airlfow [m /h] Fig. 2. Flow efficiency characteristics LUNA 200...
  • Page 5: Assembly

    2. Assembly 2.1. Required exploitation conditions The unit and ducts should be assembled in rooms with temperature above 5°C and heat- separated form surroundings. Not following above conditions will cause liquefaction of condensate and cumulate it inside and outside of the unit which may cause dampness in the room or damage to the unit.
  • Page 6: Assembly Of Siphon Out Condensate

    From air inlet To launcher From rooms To rooms Fig.3. Connection of ventilation ducts 2. Assembly of condensation dreinage system Steam condensation can be observed during unit's work. It is completely normal and it does not mean abnormality in working. In order to siphon out condensate the unit is equipped with stub pipe placed on the right side.
  • Page 7: Connecting To Power Grid

    Siphon Fig. 4. Place of pipe Fig. 4. Connection box 2.5. Conneting to power grid Unit should be connected directly to one phase outlet 230V/50Hz in the most accessible place. Unit comes with 2 m power cord and connection box to which 5x1mm or 5x1,5mm power cord and 3-gear controller shoud be connected.
  • Page 8 DOSPEL LO M H WARNING!!! Supply voltage VAC, 50Hz (the current protection should be selected based on the device's power) Manner of connecting 3 gear controller Luna 200 3 gear controller connection box Power cord 3x1,5mm Main power supply 230V AC 50Hz...
  • Page 9: Starting The Unit

    3. STARTING THE UNIT 3.1. General remarks 1.Prior to starting the unit read the manual. 2.Check if there is no objects present in the ducts which may damage the unit or endanger health. 3.It is recommended to test the working mode of the unit prior to connecting it to ventilation.
  • Page 10: Summer Mode

    10 minutes. 3.3. Summer mode Luna 200 is equipped with baypass which is activated by lever placed on the casing. The moment when bypass is opened, heat exchange does not take place. To open bypass turn lever by 90 degree counterclockwise. Bypass helps to cool ventilated rooms with...
  • Page 11: Exploitation Recommendation

    Fig.6. Summer bypass opened Fig.7. Summer bypass closed 3.4. Exploitation recommendation Necessity of filter replacement is signaled by countdown timer via visual warning. The filter cartridge made of polyester fabrics cannot be cleaned and must be replaced with a new one if necessary. New filters should be ordered from the device supplier. The time indicator of contamination of the filter counts down the time remaining until the next filter change.
  • Page 12: Controller Maintenance Manual

    Dospel guarantees repairs witin 2 years from date of purchase. Claims resulting from warranty are brought up with the day of purchase. They expire with the end of warranty of a given product, counted from the day of purchase. Warranty obliges Dospel to remove failures caused by manufacturer.
  • Page 13 Dospel provides warranty and after-warranty service. The manner of removing faults is decided by Dospel. In terms of warranty, Dospel decision is the final one. In case of any disputable matters, they will be settled by court suitable to warrantor. Dospel may refrain from keeping the repair stage when the processes occurring at Dospel will be disturbed by e.g, natural disasters with social unrest or other factors that may affect the time frame...
  • Page 15 42-280 Częstochowa tel. +48 34 365 98 43 fax +48 34 360 97 00 e-mail: dospel@dospel.com www.dospel.com Dospel reserves the right to introduce any changes regarding its products resulting from ongoing technical development. Dospel shall not be liable for printing errors.

Table of Contents