Advertisement

Quick Links

Below documentation shall be kept by user!
In case of not following the conditions of this document, the warranty expires.
dospel@dospel.com
facebook.com/Dospel.Wentylacja
MAINTENANCE MANUAL
WARRANTY CARD
www.dospel.com
twitter.com/dospel_com
luna 350
AIR HANDLING UNIT
test
+48 (34) 370 30 00
snapchat: dospel.com
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Luna 350 and is the answer not in the manual?

Questions and answers

Summary of Contents for DOSPEL Luna 350

  • Page 1 MAINTENANCE MANUAL WARRANTY CARD luna 350 AIR HANDLING UNIT test Below documentation shall be kept by user! In case of not following the conditions of this document, the warranty expires. dospel@dospel.com www.dospel.com +48 (34) 370 30 00 facebook.com/Dospel.Wentylacja twitter.com/dospel_com snapchat: dospel.com...
  • Page 2: Table Of Contents

    2.6. Manner of setting anti-freeze protection.......... 2.7. Electrical connection scheme............3. STARTING THE UNIT..............3.1. General remarks................ 3.2. Starting the unit................. 3.3. Use and maintenance..............3.4. Exploitation recommendation............Controller maintenance manual ............ 5. WARRANTY................. test dospel@dospel.com www.dospel.com +48 (34) 370 30 00...
  • Page 3: General Information

    1.MAINTENANCE MANUAL 1.1. Purpose Luna 350 air handling unit is designed to assure air exchange in public utility and apartment buildings. The unit's puprose it to supply fresh air from the outside and dispose used air from the rooms with simultaneous recovery of thermal energy. As standard, the unit is equipped with with bypasswhich can be switched on withous opening the casing.
  • Page 4: Assembly

    WARNING! Luna 350 should be lifted by holding the casing. It is forbidden to lift by holding the connectors. It may result in leakage and damage to the device. 1171 1014 Fig.1. Nominal dimensions of Luna 350 2. ASSEMBLY 2.1. Required exploitation conditions The unit and ducts should be assembled in rooms with temperature above 5°C and heat-separated...
  • Page 5: Pre-Assembly Requirements

    P[Pa] Luna 350 with 3-gear controller U[m /h] First gear Second gear Third gear Fig.2. Flow efficiency characteristics 2.2. Pre-assembly requirements While planning the assembly of the unit consider: ensuring the expliotation conditions of the unit possibility of bringing about ventilation pipes to the device...
  • Page 6: Assmbly Of Siphon-Out Condensate

    Shipon should be palced around 120 mm from the unit and radius should not be less than R=30 mm. Given measures should be taken as minimal. Unit is sold with siphon and pipe, test dospel@dospel.com www.dospel.com +48 (34) 370 30 00...
  • Page 7: Conneting To Power Gird

    2.6.Manner of setting anti-freeze protection Luna 350 ventilation unit has been equipped with anti-freeze protection heat exchange in the form of a thermostat switching off intake fan. This protection is to protect the exchanger from freezing during the occurrence of negative temperatures in winter time.
  • Page 8: Electrical Connection Scheme

    Fig 6. Electrical connection scheme test rev. 14.03.2016 dospel@dospel.com www.dospel.com +48 (34) 370 30 00...
  • Page 9: Starting The Unit

    When performing and testing the installation, appropriate safety measures must be taken in order to avoid the wrong air flow direction, i.e from an open flue pipe or other devices with open fire to the room. test rev. 14.03.2016 dospel@dospel.com www.dospel.com +48 (34) 370 30 00...
  • Page 10: Starting The Unit

    Visual indication informs about the need to replace filter. When replaced, reset the timer. WARNING! Unit should not work without filters. It is only recommended for testing, but no longer than 10 minutes. test dospel@dospel.com www.dospel.com +48 (34) 370 30 00...
  • Page 11: Exploitation Recommendation

    The drain connection may become contaminated by solid particles carried by the air over time. Periodically check (by flushing with water) the permeability of the connector. Clean if needed. Clean inlet and exhaust diffusers (if necessary). test rev. 14.03.2016 dospel@dospel.com www.dospel.com +48 (34) 370 30 00...
  • Page 12: Controller Maintenance Manual

    Nominal power supply voltage [V] 1~230 AC Nominal current [A] Number of gears Dimensions [mm] 86x86x40 Maximum surrounding 56x47x19 temp. [°C] International Protection Rating IP 40 FIRST GEAR Symbol SECOND GEAR THIRD GEAR test dospel@dospel.com www.dospel.com +48 (34) 370 30 00...
  • Page 13: Warranty

    This warranty is valid only in territory of Poland. Warranty: Dospel guarantees repairs witin 2 years from date of purchase. Claims resulting from warranty are brought up with the day of purchase. They expire with the end of warranty of a given product, counted from the day of purchase.
  • Page 14 Dospel provides warranty and after-warranty service. The manner of removing faults is decided by Dospel. In terms of warranty, Dospel decision is the final one. In case of any disputable matters, they will be settled by court suitable to warrantor. Dospel may refrain from keeping the repair stage when the processes occurring at Dospel will be disturbed by e.g, natural disasters with social unrest or other factors that may affect the...
  • Page 15 Product information according to Commission Regulation no 1253/2014 and Commission Regulation no 1254/2014 Unit Luna 350 Supplier Dospel Sp. z o.o. Device indentifier 012-1480 Luna 350 Specific energy consumtion (SEC) - average climate Specific energy consumtion (SEC) - cold climate...
  • Page 16 Product information according to Commission Regulation no 1253/2014 and Commission Regulation no 1254/2014 Unit Luna 350 0,06 [m /s] Flow rate [Pa] Pressure difference rate Specific power input (SPI) 0,38 [W/( m /h) Control factor (CTRL) Internal leakage rate Not more than 2...
  • Page 17 14.03.2016 dospel@dospel.com www.dospel.com +48 (34) 370 30 00...
  • Page 18 The selective collection of electronic and electric equipment. After the period of a given product's exploitation, it mustn't be recycled as the unsorted communal waste. test dospel@dospel.com www.dospel.com +48 (34) 370 30 00...
  • Page 19 ..............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................test rev. 14.03.2016 dospel@dospel.com www.dospel.com +48 (34) 370 30 00...
  • Page 20 +48 34 365 98 43 fax +48 34 360 97 00 e-mail: dospel@dospel.com www.dospel.com Dospel reserves the right to introduce any changes regarding its products resulting from ongoing technical development. Dospel shall not be liable for printing errors. test...

Table of Contents