Helios RR EC 125 Installation And Operating Instructions Manual

Helios RR EC 125 Installation And Operating Instructions Manual

Centrifugal 'in-line' duct fan
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Helios Ventilatoren
MONTAGE- UND BETRIEBSVORSCHRIFT
EC-Rohrventilatoren
Baureihe
RR EC ...
NR. 82 839
D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RR EC 125 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Helios RR EC 125

  • Page 1 Helios Ventilatoren MONTAGE- UND BETRIEBSVORSCHRIFT NR. 82 839 EC-Rohrventilatoren Baureihe RR EC ...
  • Page 2 DEUTSCH...
  • Page 3: Table Of Contents

    Inhaltsverzeichnis KAPITEL 1. EC-ROHRVENTILATOREN RR EC 125/160/200/250/315 SCHNELLÜBERSICHT ....Seite 2 EC-Rohrventilatoren RR EC ... Typenübersicht ..........Seite 2 Abmessungen .
  • Page 4: Ec-Rohrventilatoren Rr Ec

    Montage- und Betriebsvorschrift EC-Rohrventilatoren – RR EC ... EC-Rohrventilatoren RR EC ... Typenübersicht KAPITEL 1 EC-Radialrohrventilator RR EC ... RR EC 125/160/200/250/315 mit stufenloser Drehzahlsteuerung und energieeffizientes, rückwärts SCHNELLÜBERSICHT gekrümmtes Radiallaufrad aus Kunststoff. Baureihe RR EC 125 Best.Nr. 5789 RR EC 160 Best.Nr.
  • Page 5: Wichtige Informationen

    Wenn die vorhergehenden Ausführungen nicht beachtet werden, entfällt unsere Gewährleistung und Behandlung auf Kulanz. Gleiches gilt für Haftungsansprüche an den Hersteller. Der Gebrauch von Zubehörteilen, die nicht von Helios empfohlen oder angeboten werden, ist nicht statthaft. Even tuell auftretende Schäden unterliegen nicht der Gewährleistung.
  • Page 6: Sicherheit

    Der Einsatz von Fremdfabrikaten kann, vor allem bei elektronischen Geräten, zu Funk ti ons pro ble men, Zer- ACHTUNG störung des Reglers und/oder des Ventilators führen. Bei Einsatz seitens HELIOS nicht freigegebener Regel- und Steuergeräte entfallen Garantie und Haf tungs an sprü che.
  • Page 7: Wartung

    Montage- und Betriebsvorschrift EC-Rohrventilatoren – RR EC ... 2.17 Wartung Vor allen Wartungs- und Installationsarbeiten oder vor Öffnen des Klemmenkasten ist das Gerät allpolig WARNUNG vom Netz zu trennen! Übermäßige Ablagerung von Schmutz, Staub Fetten u.a.m. auf Lauf rad, Motor, Schutz git ter und vor allem zwischen Gehäuse und Laufrad sind un zu läs sig und durch pe ri odi sche Rei ni gung zu un ter bin den.
  • Page 8: Elektrischer Anschluss

    RR EC-Baureihen mit dem Universal-Regelsystem EUR EC (Art.-Nr. 1347) betrieben werden (Anschlussbeispiel Abb. 6 beachten). Der Elektroanschluss muss bis zur Endmontage allpolig vom Netz getrennt werden! WARNUNG Anschlussschema SS-979 Baureihen Abb.4 SS-979 RR EC 125 RR EC 160 RR EC 200 EC-Motor RR EC 250 RR EC 315 Klemmkasten Potentiometer bauseits zu stellen bzw.
  • Page 9: Anschlussbeispiel Mit Universal-Regelsystem Eur Ec

    Montage- und Betriebsvorschrift EC-Rohrventilatoren – RR EC ... Drehzahl-Potentiome- Anschlussschema mit Drehzahl-Potentiometer PU/A 10, SS-980 ter und Regelsystem Abb.5 SS-980 für Baureihen RR.. EC Anschlussbeispiel mit Universal-Regelsystem EUR EC, SS-981 Abb.6 SS-981...
  • Page 10: Anschluss-Prinzip Ss-1035

    Poti aus einer 10V Versor- mit einem Poti aus einer 10V Ventilatoren mit gung (ohne PU/A LED) Versorgung (mit PU/A LED) EUR EC RR EC 125 10V / 1,1mA 0-10V / 0,1mA (Ri=94kOhm) LED nicht möglich RR EC 160 10V / 1,1mA 0-10V / 0,1mA (Ri=94kOhm) LED nicht möglich...
  • Page 11: Erstinbetriebnahme

    Montage- und Betriebsvorschrift EC-Rohrventilatoren – RR EC ... Erstinbetriebnahme KAPITEL 5 Vor der Erstinbetriebnahme sind folgende Punkte zu prüfen: – Bestimmungsgemäßen Einsatz des Rohrventilators über prüfen! INBETRIEBNAHME – Einbau und elektrische Installation fachgerecht abgeschlossen – Ventilator auf solide Befestigung prüfen –...
  • Page 12 HELIOS Ventilatoren GmbH & Co · Lupfenstraße 8 · 78056 VS-Schwenningen HELIOS Ventilateurs · Z.I. La Fosse à la Barbière · 2, rue Louis Saillant · 93605 Aulnay sous Bois Cedex CH HELIOS Ventilatoren AG · Steinackerstraße 36 · 8902 Urdorf / Zürich GB HELIOS Ventilation Systems Ltd.
  • Page 13 ENGLISH Helios Ventilatoren INSTALLATION AND OPERATING INSTRUCTIONS No. 82 839 EC-Centrifugal ‘In-Line’ Duct Fan Types RR EC ...
  • Page 14 ENGLISH...
  • Page 15 Contents CHAPTER 1. EC-CENTRIFUGAL ‘IN-LINE’ DUCT FANS RR EC 125/160/200/250/315 QUICK OVERVIEW . . . Page 2 EC-Centrifugal ‘In-Line’ Duct fans RR EC ... Overview of types ........Page 2 Dimensions .
  • Page 16: Ec-Centrifugal 'In-Line' Duct Fans Rr Ec

    EC-Centrifugal ‘In-line’ Duct Fans – RR EC ... EC-Centrifugal ‘In-line’ Duct fans RR EC ... Overview of types CHAPTER 1 EC-Centrifugal ‘In-line’ duct fan RR EC ... RR EC 125/160/200/250/315 with stepless speed control and energy-saving, backward curved centri- QUICK OVERVIEW fugal impeller made from polymers.
  • Page 17: Chapter 2. Gerneral Information

    If the preceding instructions are not observed all warranty claims and accommodation treatments are excluded. This also applies to any liability claims extended to the manufacturer. The use of accessories not offered or recommended by Helios is not permitted. Potential damages are not liable for warranty.
  • Page 18: Protection Against Accidental Contact

    The use of other brands, especially other electronic devices, can lead to malfunctioning and even destruc- WARNING tion of controller and/or fan. Controllers which have not been cleared by Helios are not liable for warranty and guarantee claims. 2.13 Condensation water formation In case of periodial use, moist and warm media and through temperature variations (intermittent service) condensate- may build up in the motor and its draining off must be ensured.
  • Page 19: Chapter 3. Installation

    Installation and Operating Instructions EC-Centrifugal ‘In-line’ Duct Fans – RR EC ... Installation CHAPTER 3 It is recommended to leave the unit until installation in the original packaging to avoid possible damages and soiling. The fans are delivered in standard execution as a a complete unit, i.e. ready to plug in.They can be mounted in any INSTALLATION position -horizontal, -vertical, -diagonal .
  • Page 20: Chapter 4. Electrical Connection

    (Ref.no.1347) (observe connection example fig.6). The electrical connection must be fully isolated from the supply until final assembly ! WARNING Wiring diagram SS-979 Types fig.4 SS-979 RR EC 125 RR EC 160 RR EC 200 EC-Motor RR EC 250 RR EC 315 Klemmkasten Potentiometer bauseits zu stellen bzw.
  • Page 21 Installation and Operating Instructions EC-Centrifugal ‘In-line’ Duct Fans – RR EC ... Speed potentiometer Wiring diagram with speed potentiometer PU/A 10, SS-980 and universal control fig.5 SS-980 system for types RR.. EC Example: Connection with Universal-Controller EUR EC, SS-981 fig.6 SS-981...
  • Page 22: Chapter 5. Putting Into Operation

    Installation and Operating Instructions EC-Centrifugal ‘In-line’ Duct Fans – RR EC ... Final start-up CHAPTER 5 Following checks need to be done: – Check intended use of fan PUTTING INTO OPERATION – Check if fan is securely mounted – Check adequate fixing –...
  • Page 23: Notes

    Installation and Operating Instructions EC-Centrifugal ‘In-line’ Duct Fans – RR EC ... Notes:...
  • Page 24 HELIOS Ventilatoren GmbH & Co · Lupfenstraße 8 · 78056 VS-Schwenningen HELIOS Ventilateurs · Z.I. La Fosse à la Barbière · 2, rue Louis Saillant · 93605 Aulnay sous Bois Cedex CH HELIOS Ventilatoren AG · Steinackerstraße 36 · 8902 Urdorf / Zürich GB HELIOS Ventilation Systems Ltd.
  • Page 25 Helios Ventilatoreurs NOTICE DE MONTAGE ET D’INSTALLATION N° 82 839 Ventilateurs centrifuges EC Série RR EC ...
  • Page 26 FRANÇAIS...
  • Page 27 Sommaire CHAPITRE 1. VENTILATEURS CENTRIFUGES RR EC 125/160/200/250/315 VUE D’ENSEMBLE ..Page 2 Ventilateurs centrifuges EC RR EC.. Vue d’ensemble des modèles ....... . Page 2 Dimensions .
  • Page 28: Ventilateurs Centrifuges Ec Rr Ec

    Ventilateurs centrifuges EC RR EC ... Vue d’ensemble des modèles CHAPITRE 1 Ventilateurs centrifuges RR EC ... RR EC 125/160/200/250/315 avec régulation de vitesse progressive et hélice centrifuge à haut rende- VUE D’ENSEMBLE ment, à réaction et en matière synthétique.
  • Page 29: Informations Importantes

    Si ces consignes ne sont pas respectées, la garantie s’annule. Idem pour les réserves constructeur. L’utilisation d’accessoires non fournis, non conseillés ou non proposés par Helios, est interdite. Les dégâts éventuels causés par cette utilisation ne sont pas pris en charge.
  • Page 30: Protection

    Si l’alimentation EC n’est pas atteinte, une tension externe de 10 VDC peut être installée (fourniture client), en dehors du réseau galvanique. Le module « EUR EC » de Helios peut également être installé pour configurer diverses consignes de tension. 2.13 Formation des condensats En cas de fonctionnement intermittent, de transport de fluides humides ou chauds, de variations de température, il se...
  • Page 31: Maintenance

    Notice d’installation et d’utilisation Ventilateurs centrifuges EC – RR EC ... 2.17 Maintenance Avant tous travaux d’installation ou avant ouverture de la boîte à bornes, vérifier que l’appareil est hors AVERTISSEMENT tension ! D'importants dépôts de poussières, graisses, matériaux divers peuvent se trouver sur l'hélice, le moteur, les grilles de protection et tout particulièrement entre le caisson et l'hélice.
  • Page 32: Raccordement Électrique

    Le raccordement électrique doit se faire hors tension jusqu’à la fin du montage ! AVERTISSEMENT Schéma de raccordement SS-979 Séries Fig. 4 SS-979 RR EC 125 RR EC 160 RR EC 200 Moteur EC RR EC 250 RR EC 315 Bornier Potentiomètre...
  • Page 33 Notice d’installation et d’utilisation Ventilateurs centrifuges EC – RR EC ... Potentiomètre de Schéma de raccordement avec le potentiomètre de vitesse PU/A 10, SS-980 vitesse et régulateur Fig. 5 SS-980 pour séries Moteur SS-979 RR.. EC PU/A 10 Réf. n° 1734/1735 Potentiomètre Vitesse min.
  • Page 34: Données Techniques Des Tensions D'entrée

    10 V tiomètre avec alimentation de cordés avec EUR (sans LED PU/A) 10 V (avec LED PU/A) RR EC 125 10 V/1,1 mA 0-10 V/0,1 mA (Ri=94 kOhm) LED non possible RR EC 160 10 V/1,1 mA...
  • Page 35: Première Mise En Service

    Notice d’installation et d’utilisation Ventilateurs centrifuges EC – RR EC ... Première mise en service CHAPITRE 5 Vérifier les points suivants avant la première mise en service : – la conformité de l’installation du ventilateur centrifuge selon les prescriptions. MISE EN SERVICE –...
  • Page 36 HELIOS Ventilatoren GmbH & Co · Lupfenstraße 8 · 78056 VS-Schwenningen HELIOS Ventilateurs · Z.I. La Fosse à la Barbière · 2, rue Louis Saillant · 93605 Aulnay sous Bois Cedex CH HELIOS Ventilatoren AG · Tannstrasse 4 · 8112 Otelfingen GB HELIOS Ventilation Systems Ltd.

This manual is also suitable for:

Rr ec 160Rr ec 200Rr ec 250Rr ec 315

Table of Contents