Download Print this page

Emerson Klauke EK 120/42CFB Manual page 7

Advertisement

EK 120/42CFB
1
2
ERROR CODE:
****
3
BT
P 3
bar
P 3
bar
4a
USER 3:
RD3
D o p p el k l i c k
4b
U S E R S E L EC T 3:
R D 3
E i nf a c h kl i c k
3 sec.
4c
U S E R S E L EC T :
R D 3
D o pp e l k li c k
4d
U S E R S E L EC T :
R D 3
D o pp e l k li c k
Klauke i-press
Klauke i-press
www.klauke.com/connectivity
www.klauke.com/connectivity
Klauke i-press
Klauke i-press
HE.16783_G © 05/2016
5
6
7
Error code
*1
*2
Bluetooth (if connected)
Battery charging level
Current pressure
Pressure max.
Doubleclick
Singleclick
enter menue
Doubelclick
select
Doubelclick
confi rmed
®
®
Software
Software
®
®
App
App
WORK
SERVICE
NEXT
SERVICE:
Cycles
9826 OP
(until next service)
s
Since manufacturing:
TOTAL:
operating houres
t = 0
07
h
.
Q = 21
12 Ah
Capacity
.
n = 174
# crimps
≤ 20 sec.
≤ 20 sec.
> 20 sec.
> 20 sec.
≤ 20 sec.
≤ 20 sec.
REPEAT
REPEAT
DON´T DO
*1
Error codes:
1 Overcurrent fuse
2 Overcurrent comparator
3 Overheat board
4 Overheat battery
5 Battery empty, operation stop
6 Faulty crimp
motor in operation
7 Faulty crimp
motor not in operation
8 Low battery
9 Battery empty
10 RTC battery low
11 Tool deactivated
12 Service necessary
13 RTC not found
14 BT unit not found
16 Pressure sensor not found
17 Burst pressure exceeded
18 Battery temperature too low
1 Überstrom durch
Überstromsicherung
2 Überstrom durch Komparator
3 Boardtemperatur zu hoch
4 Akkutemperatur zu hoch
5 Akkuspannung während der
Operation zu gering
6 Fehlpressung bei
laufendem Motor
7 Fehlpressung bei
stehendem Motor
8 Niedrige Akkuspannung
9 Akku leer
10 RTC-Batterie leer
11 Werkzeug deaktiviert
12 Service nötig
13 RTC nicht verfügbar
14 BT-Modul nicht verfügbar
16 Drucksensor nicht verfügbar
17 Berstdruck überschritten
18 Akkutemperatur zu gering
*2
(2Hz)
General
safety rules
V

Advertisement