Step 1.
Lower the
elevator for access to
the top of the car
Step 2.
Identify the detector
wiring - normally open (NO)
or normally closed (NC) - to
the door controller
Step 3.
Ensure all power to
the elevator is turned off
before touching the wiring
Step 4.
Rewire the
detectors to the ESD
controller IN port
Step 5.
Using the wiring
loom provided, wire the
ESD controller OUT port
to the door controller
Step 6.
Finding a 24V
power source to supply
power to the ESD
controller via port 1 (see
above), turn the elevator
power on to supply
power to the system -
an audible signal will
indicate the ESD unit is
operational (Please use
Class 2 related power
supply in the USA)