Main chapter overview Instruction manual Instruction manual ........................A.1.1 Duo column instruction manual ................... A.1.1 Safety instructions ......................A.1.1 Intended use ........................A.1.1 Specifications ......................... A.1.2 Requirements at the site ....................A.1.2 Electrical stipulations ..................... A.1.3 Scope of supply/accessories in the separate parts set ..........A.1.4 Installation of the column ....................
Wallbox on this column is not permitted! All installation and cable openings must be closed fol- lowing installation. Only installation of the following compatible Wallboxes is permitted: ● Heidelberg Wallbox Home Eco, ● Heidelberg Wallbox Energy Control. A.1.1 00.999.3105/...
Instruction manual You can find information about other wall-mounted charging stations that may be compatible on the homepage https://wallbox.heidelberg.com. The applicable national regulations must be observed for the installation. The column may only be used for the purpose defined in the instruction manual.
Instruction manual ● During installation, the instructions of the manu- facturer of the screw anchors used must be ob- served. ● Cable routing is only provided for through the foundation. Suitable installation conduits and connecting cables must be used. ● The anchoring in the foundation must withstand maximum pull-out forces of 7500 Nm and maxi- mum shear forces of 2000 Nm on each of the four...
Instruction manual as network cables (ModBus) or switching cables (e.g. from key switches). ● If the data cable has sufficient insulation capacity, no further separation measures from the power cable are necessary. ● If the insulation capacity of the data cable is not guaranteed, other measures must be applied in accordance with national specifications (e.g.
Instruction manual ● two adapter plates. ● one separate parts set, consisting of: Parts for the ground connection: ○ one contact disk, ○ two washers, ○ one spring ring, ○ one nut. Parts for attaching the Wallboxes: ○ eight M6x16 countersunk screws to fasten the adapter plates to the column, ○...
Page 10
Instruction manual must be separated from one another when laying the foundation. ● All cables must emerge from the floor in the mid- dle of the concrete foundation within a quadratic area of max. 50 mm x 50 mm. ● The protective hose or conduit must have an ex- cess length of approx.
Instruction manual Fastening the adapter plates The adapter plates provided have separate cable feed-throughs for the power cables and the data cables. Fasten the matching cable protecting sleeves (Fig. 3/1) contained in the separate parts set to the cable outlet openings of the adapter plates.
Instruction manual Fasten the adapter plates (Fig. 5/1) to the column using the four M6x16 countersunk screws pro- vided for each plate. Tightening torque 7 Nm. Start with the adapter plate on the side of the col- umn with the smaller installation opening. Fig.
Instruction manual 1.12 Contact address/Customer Sales Representative Hotline: +49 6222 82-2266 E-mail: wallbox@heidelberg.com Contact language: German and English. Website: https://wallbox.heidelberg.com/ 1.13 Disposal After the Wallbox has been correctly decommissioned, dispose of the column according to the currently valid disposal regulations.