Congratulations on your purchase of the SMR MAXI Cabinet. We truly appreciate your business, and we’re grateful for the trust you’ve placed in us...
THE SAFETY AND SATISFACTION OF OUR CUSTOMERS AND THEIR PATIENTS ARE WARNING THE HIGHEST PRIORITIES OF GLOBAL SURGICAL CORPORATION. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE SAFE AND PROPER USE OF THIS EQUIPMENT AND SHOULD BE READ THOROUGHLY BY ALL OPERATORS PRIOR TO THEIR FIRST USE OF THE EQUIPMENT.
Section 1 Important Safety Instructions This symbol indicates a situation in which incorrect handling through disregard of a WARNING warning might result in death or serious personal injury. This symbol indicates a situation in which incorrect handling through disregard of a CAUTION caution might result in personal injury or may result in damage to property.
Page 8
Non-use of the hydrophobic filter may lead to possible contamination and pump failure. Global Surgical will not receive or replace any pump in which the CAUTION Hydrophobic Filter was not used.
Page 9
Safe Working Load: 2 KG (4 lbs.) each drawer or shelf or counter surface. CAUTION Duty Cycle: 10 min. maximum On Vacuum/Pressure, 10 min. Off. Replacement parts, such as cables, must be purchased through Global Surgical to ensure proper compliance requirements. Unauthorized use of these items will CAUTION void warranty and may cause injury to you, others and/or the equipment.
Page 10
CAUTION Some of the parts may be damaged by knives. Open boxes carefully. CAUTION Check for damage before discarding the shipping material and notify Global Surgical NOTE Customer Service if shipping damage is observed. Contents are packed in several boxes. Before discarding any packaging, ensure no NOTE components are still within.
Section 2 Unpacking and Preparation for Use 2.1. Pump Connections ELECTRICAL SHOCK HAZARD! CONNECT THE SMR MAXI CABINET ONLY WARNING TO A PROPERLY-WIRED GROUNDED RECEPTACLE. The pumps in the cabinet have been secured for shipment by tape. Before CAUTION operating them remove the tape. Failure to cut and remove the shipping tape from around the two pumps will result in damage to the pumps.
Section 2 Unpacking and Preparation for Use 2.2. Setting Up the S WA77710 Wall Transformer If the cabinet has a S WA77710 Wall Transformer, the wall transformer and two corded illumination handles are attached to the side of the cabinet and are ready for use. Attach the instrument heads of your choice to the handles.
The Pressure Pump has a regulated air pressure supply and an assortment of glassware attachments. See your Global Surgical Sales Representative for the available glassware options. Three illumination options are available: corded or rechargeable handles for the otoscope and transilluminator heads, or optional high output sources to supply light to devices with fiber optic cables.
Section 3 Product Information 3.2. System Parts Stainless Steel Standard Cabinet shown OPTIONAL S 740257 GLASS BEAD WARMER WITH OPTIONAL MIRROR WARMER SHELF GLASSWARE WELL CONTROL PANEL OPTIONAL 123-007-072 RECHARGEABLE HANDLE RECHARGING WELLS (2 PLACES) SUCTION HOSE S 740275USB 115V, 2A AUXILIARY OUTLET OPTIONAL...
Section 3 Product Information 3.3. Specifications Table 3-1 Specifications STAINLESS STEEL LAMINATE ALUMINUM COMPOSITE ALL DIMENSIONS ARE IN INCHES. STANDARD DELUXE STANDARD DELUXE STANDARD DELUXE MINI STANDARD DELUXE TALL TALL TALL TALL OVERALL HEIGHT HIGH 60.5 60.5 49.5 60.5 49.5 60.5 BACK, W/CASTERS (N/A)
Section 3 Product Information 3.4. Vacuum Pump and Canister System Specifications The Vacuum Pump is a 110-120V, 3.2/1.7 A, 60 Hz, thermally protected, piston-type pump. The pump will draw down to a maximum of 25 inches (635 mm) of mercury. Unrestricted air flow is 4.4 cubic feet (125 liters) per minute.
The S 740257 Glass Bead Mirror Warmer warms mirrors to prevent fogging by placing the mirror into the hot beads for three to five seconds. The Glass Bead Mirror Warmer uses S 1006102 Replacement glass beads which are avaliable from Global Surgical. See Premier Medical Products, product information sheet 051077 Rev3 PMM enclosed with unit for complete details.
Section 4 Operating Instructions 4.1. Operation and Controls 4.2. Control Panel - Main Power Switch To turn on power to the cabinet, push the rocker switch to the “I” position. The switch will light up when there is power to the cabinet. Push the switch to the “O” position to turn the power off. See Figure 4.1. for the location of the Control Panel.
Section 4 Operating Instructions 4.4.1. Corded Instruments S WA77710 Wall Transformer w/ Otoscope Handles Decreasing the light output to minimum level does not power down the instrument. Returning NOTE the handle to cradle will power the instrument down. TURN RHEOSTAT CLOCKWISE TO INCREASE THE LIGHT OUTPUT...
Page 20
Section 4 Operating Instructions The Pulsating Light shows that current is flowing and that the battery is being recharged. When the Light is permanently lit, the charging sequence is completed. The battery in the handle is fully-charged. If Light is off, this indicates that the compartment is empty. Figure 4-4.
Section 4 Operating Instructions 4.5. Optional Light Source 4.5.1. Optional S 740200LED LED Light Source With Turret Figure 4-6 LED Light Source Front Panel Name Function Power switch Turns the light source on and off. Fan will operate Turret type to fit your choice of four: Storz, ACMI, Wolf, Light guide adapter Olympus Intensity control knob...
4.6. Optional S 740258A Drawer Warmer 4.6.1. Powering Up the Drawer Warmer Do not try to repair the drawer warmer. Call Global Surgical Technical Service for service WARNING information. Do not remove instrument tray from drawer warmer during use. CAUTION The drawer warmer has an automatic time out after 9 hours and will shut off.
Section 4 Operating Instructions 4.8. Optional S 7401355 Suction / Pressure Foot Switch NOTE To use the foot switch, the switch on the control switch panel must be set to the “OFF” position. MAIN S M R PRESSURE VACUUM POWER MAXI Turn the Control Panel Switch to the OFF Position...
Section 4 Operating Instructions 4.9.3. Pressure Adjustment PRESSURE THAT IS TOO HIGH COULD RESULT IN HAZARDOUS OUTPUT FOR WARNING DISPENSING MEDICATIONS. NOTE The pressure can only be set with the air restricted at the open-air cutoff tip. Pressure Gauge Pressure Control Knob Detail A Figure 4-10.
Section 5 Care and Maintenance 5.1. Cleaning and Disinfecting ELECTRICAL SHOCK HAZARD! DISCONNECT ALL ELECTRICAL POWER PRIOR WARNING TO CLEANING AND DISINFECTING. DO NOT ALLOW EXCESSIVE MOISTURE OR LIQUIDS TO COME IN DIRECT CAUTION CONTACT WITH THE UNIT. DO NOT CLEAN ANY SURFACE WITH PETROLEUM-BASED SOLVENTS SUCH AS ACETONE OR METHYL ETHYL KETONE (M.E.K.), OR SALTY ACIDS SUCH AS HCL.
Section 5 Care and Maintenance 5.1.3. Glassware, Otoscopes, Mirror Warmer and Lightsource Please refer to the instructions for use prepared by the manufacturers for cleaning and disinfection instructions. 5.1.4. Stainless Steel Surfaces Clean with any commercial stainless steel cleaner/polish. Read the directions and test in an inconspicuous spot 5.1.5.
Section 5 Care and Maintenance 5.2. General Maintenance ELECTRICAL SHOCK HAZARD! DISCONNECT ALL ELECTRICAL POWER PRIOR WARNING TO SERVICING CABINET. CABINET OR OPTIONAL EQUIPMENT SHALL NOT BE SERVICED OR WARNING MAINTAINED WHILE IN USE WITH A PATIENT. Check with the applicable biomedical engineering or local government agencies for additional NOTE guidelines on maintenance intervals on equipment in your facility.
Section 5 Care and Maintenance 5.3. Replacing the S 600001 Disposable Canister Canister is Single Use Only. Do not attempt to clean, sterilize or reuse canister. CAUTION Possible consequences of reuse include: 1) Implosion, 2) Fluid bypass, and 3) Exposure to blood borne pathogens.
Page 29
Section 5 Care and Maintenance Pour Spout Vacuum Hose Attachment Tandem Patient Hose Attachment Port B Port A Patient Hose Canister Lid Attachment Vacuum Hose Attachment Canister Bracket Quick Ordering Label For quick ordering of SMR Filters, Tubing, Canisters, Call: GLOBAL 1-800-861-3585 Figure 5-1.
Section 5 Care and Maintenance 5.4. Replacing the S 740600C Disposable Canister Liner Canister Liner is Single Use Only, Do Not attempt to clean, sterilize or reuse canister CAUTION liner. Possible consequences of reuse include: 1.) Implosion, 2) Fluid bypass, and 3) Exposure to blood borne pathogens.
Section 5 Care and Maintenance A HYDROPHOBIC FILTER MUST BE USED TO PREVENT CONTAMINANT DAMAGE TO THE PUMP. GLOBAL SURGICAL WILL NOT RECEIVE OR REPLACE ANY PUMP WARNING WHERE THIS FILTER HAS NOT BEEN USED. Extended use of alcohol or solvents may reduce the efficiency of the microporous membrane of the HYDROPHOBIC FILTER.
Section 5 Care and Maintenance 5.6. Replacing the fuse in the Optional S 740200LED LED Light Source ELECTRICAL SHOCK HAZARD! DISCONNECT ALL ELECTRICAL POWER WARNING PRIOR TO REPLACING FUSE. THE REPLACEMENT OF THE FUSE SHOULD BE DONE ONLY BY QUALIFIED WARNING SERVICE PERSONNEL.
Page 33
Section 5 Care and Maintenance 7. On back of unit, remove fuse by turning fuse cover counter-clockwise and pulling out fuse. Replace fuse with 2 AMP (1/4” x 1 ¼”) time delay 250V rated fuse. 8. Insert back into fuse housing and twist clockwise until it clicks into position. 9.
Section 5 Care and Maintenance 5.7. Replacing the Batteries in the S 740254KP Keyless Locking System While the S 740254KP Keyless Locking System features a low battery indicator, it is recommended that the batteries be replaced annually. Mixing batteries of different chemistries could damage the system resulting in lock failure.
Section 5 Care and Maintenance 5.9. S 740275 USB Auxiliary Outlet Specification: USB Auxiliary Outlet with Dual AC (125VAC, 2.5A) and Dual USB Type A (5VDC, 3.6A) Connections, upper right side. Grounding continuity should be checked periodically. CAUTION If the 2.5A current is exceeded, the outlet will need to be reset. Reset the breaker on NOTE the power strip located in the pump compartment.
Section 6 Troubleshooting 6.1. Troubleshooting Low Suction Canister is Single Use Only, Do Not attempt to clean, sterilize or reuse canister. CAUTION Possible consequences of reuse include: 1.) Implosion, 2) Fluid bypass, and 3) Exposure to blood borne pathogens. Dispose of the disposable suction canister containing medical waste in an environmentally CAUTION safe manner per state and federal regulations.
Section 6 Troubleshooting 3. Push the tubing back on the hydrophobic filter barb. Pull the tubing off the vacuum right-angle fitting on the center of the canister lid. Turn on pump. Put your finger over the tubing. If there is not good suction, then the section of tubing needs to be replaced.
Service. Refer to Section 7 in this manual for contact information. If it becomes necessary to return the unit to the Global Surgical factory, again refer to Section 8 for instructions. Table 6-1 contains a list of many common problems that you may be able to correct yourself.
Page 39
2. Repair or replace any leaking hoses, fittings or connections. E. Pump or its control circuit is Call Global Surgical Technical Service. malfunctioning. Cabinet Electrical System A. Cabinet is not plugged in or plug is Check cabinet plug and wall loose from the wall receptacle.
Page 40
C. Instrument loose or defective Reseat or replace bulb. Illuminator does not operate (corded only) D. Illuminator circuit malfunction Call Global Surgical Technical Service E. both instruments are out of the Only one instrument can be powered at cradle a time F.
7.1. Cabinet Pump Compartment Components NOTE: If you need more information than provided in this user manual, Global Surgical will provide assistance to SERVICE PERSONNEL for parts repair. See Section 8.2 for Technical Service contact information. Table 7-1 Pump Compartment Components...
SMR cabinets, chairs, and associated accessories include a one-year warranty from defects, which covers parts and labor. Except as set forth in this Limited One – Year Warranty, Global Surgical Corporation (the “Company”) hereby warrants that each SMR (ENT cabinets, exam chairs, and stools) product manufactured and sold by the company (“Product”) shall be free from defects in materials and workmanship under normal use and service...
If service is required at your location, a skilled technician or sales representative will be dispatched within 24 hours. If you have questions that are not covered in this manual, please call the Global Surgical Technical Service Department as listed below:...
Section 9 Technical Data Appendix A Appendix A-1 Cabinet Model/Type ................A-1 Appendix A-2 List of Accessories .................. A-2 Appendix A-3 Test Standards..................A-6...
Section 9 Technical Data Appendix A-1 Cabinet Model/Type...
Page 48
Section 9 Technical Data Appendix A-2 Accessories PART NUMBER DESCRIPTION S 189000 LOCKING CABINET FOR MAXI CABINET S 189000S LOCKING CABINET FOR MAXI CAB, SHORT S 3312 OINTMENT JAR 3-1/8 X 2-1/2 S 400446 SUCTION TUBING .406 OD X 1/4” ID, GREY S 600001 DISPOSABLE SUCTION CANISTER S 600006...
Page 49
Section 9 Technical Data Accessories (continued) S 740270 STAINLESS STEEL, TISSUE DISPENSER BOX - USER POSITIONABLE S 740271 STAINLESS STEEL, GLOVE DISPENSER BOX - USER POSITIONABLE S 740273 INDENTATION FOR MIRROR WARMER IN CABINET COUNTER TOP S 740274D TRADITIONAL GLASSWARE UPGRADE FOR DELUXE CABINET S 740274S TRADITIONAL GLASSWARE UPGRADE FOR STANDARD CABINET S 740275-USB...
Page 50
Section 9 Technical Data Accessories (continued) S DV180 GLASS NEBULIZER S DV200 DEVILBISS GLASSWARE UPGRADE, STANDARD CABINET S DV286 GLASS ATOMIZER AMBER S DV286OT PLASTIC OUTLET TUBE, 4 1/3” FOR # S-DV286 S DV300 DEVILBISS UPGRADE DELUXE CABINET S DV400 TRADITIONAL DEVILBISS GLASSWARE UPGRADE, STANDARD CABINET S DV500 TRADITIONAL DEVILBISS GLASSWARE UPGRADE, DELUXE CABINET...
Page 51
Section 9 Technical Data Appendix A-3 Test Standrds SMR cabinet was tested to IEC 60601-1-2 ed4.0 (2014-02): Additional information provided upon request from Global Surgical Corporation. Test / Standard Emissions Class and Group /immunity test level Result CISPR 11, Conducted Emissions...
Page 52
91613 Global Surgical Corporation 3610 Tree Court Industrial Blvd. St. Louis, MO 63122 EMERGO EUROPE Prinsessegracht 20 2514 AP The Hague The Netherlands...
Need help?
Do you have a question about the SMR MAXI Deluxe and is the answer not in the manual?
Questions and answers
Can you add the keyless locking system to a cart that originally doesn't have one on it
The SMR MAXI Deluxe manual mentions the S 740254KP Keyless Locking System, including battery replacement and maintenance instructions. This suggests that the cart can include a keyless locking system, but it does not explicitly state whether it can be added as a modification.
This answer is automatically generated