Ubert HT Series User Manual

Hot display system

Advertisement

User Manual
HOT DISPLAY CABINET
HT-Series

Advertisement

Table of Contents
loading

Summary of Contents for Ubert HT Series

  • Page 1 User Manual HOT DISPLAY CABINET HT-Series...
  • Page 3: Table Of Contents

    Contents 1 Contents Contents ........................... 3 Important References........................ 4 Fundamental Safety Notes ....................4 Warranty and Liabilities ...................... 5 Symbols and Notes ......................5 Copyright ..........................5 Special safety references ....................6 Introduction ..........................8 Introduction ......................... 8 Special features ........................8 Technical details .........................
  • Page 4: Important References

    The Hot Cabinets are built exclusively for the preparation of food only. Any other use of the unit are only allowed after consulting UBERT GASTROTECHNIK GMBH. Damages which result out of wrong use UBERT GASTROTECHNIK GMBH cannot be held responsible. Part of the due use is also: ...
  • Page 5: Warranty And Liabilities

    Help to use all functions at your unit optimally 2.4 Copyright The copyright on this operating manual remains at the company UBERT GASTROTECHNIK GMBH This operating manual is intended only for the operator and his personal. It contains instructions and references wich neither completely nor partially: ...
  • Page 6: Special Safety References

    Important References 2.5 Special safety references 2.5.1 Safety devices  Before operating the unit all protective devices as well as all removable parts must be installed correctly and be fully workable.  Protective devices may only be removed:  after stand still and ...
  • Page 7 • Do not perform any changes, extensions or conversions to the unit without the manu- facturers permission, especially welding work at supporting parts. • For all conversions a written permission of the company UBERT GASTROTECHNIK GMBH is necessary. • Change all parts of the unit, that are in impropper condition.
  • Page 8: Introduction

    Introduction 3 Introduction 3.1 Introduction All Ubert Hot Cabinets operate with hot air convection. The air circulates slowely to mini- mize weight loss and drying of the products. The temperature is regulated by Thermostat. Specially designed heating elements above the water drawers humidify the air that is moved by fans circulating in the cabinet.
  • Page 9: Technical Details

    Introduction 3.3 Technical details 3.3.1 Dimensions [mm] HT 700 / HT 700 DB : HT 100 / HT 1100 DB :  TopLineUserManualHT.docx printed: 02/2015 Subject to change!
  • Page 10 Introduction HT 1400 / HT 1400 DB : 3.3.2 Weight Type weight (in kg) HT 700 HT 1100 HT 1400 HT 700 DB HT 1100 DB HT 1400 DB 3.3.3 Electrical details Type electrical connection [EA] power HT 700 230V, 1/N, 50Hz 2,8 kW HT 1100 400V, 3/N, 50Hz...
  • Page 11 Introduction all types < 70 dB (A)  TopLineUserManualHT.docx printed: 02/2015 Subject to change!
  • Page 12: Installation And Putting Into Operation

    4.3 Electrical connection Note! In general, only service technicians of the company: UBERT GASTRO- TECHNIK GMBH or service technicians of your responsible service partner are al- lowed to perform el. connection and other service! All national and lokal rules and regulations concerning electricity, fireprotection and the like have to be concidered.
  • Page 13: Preparation Of Using / Starting Up

    Installation and putting into operation 4.4 Preparation of Using / Starting up Before you can use the Cabinet you have to clean all removable parts carefully with a grease sol- vent. Note! Do not use flammable cleaners. Do not use high-pressure-, water pressure- or steam jet- cleaning machines.
  • Page 14: Operation

    Operation 5 Operation Following you will find explanation and location of all components and their function for the use of the cabinet. 5.1 Operation elements Digital Control 5.2 Operation STANDBY button Switches the cabinet ON and OFF. LIGHT Button Switches the lights inside the cabinet ON and OFF. PPROGRAMMING button Keep pushed to change the set temperature using...
  • Page 15: Optional

    Operation DISPLAY The DISPLAY shows the actual temperature. While is pushed, it shows the set temperature. While the Cabinet is switched off the display shows “OFF” Water Drawers: Fill with water to increase air humidity in the cabinet. It is located behind the section for cutlery.
  • Page 16: Maintenance

    Maintenance 6 Maintenance Following we will show you some advices concerning maintenance, care, trouble shooting and ser- vice for your Hot Cabinet. 6.1 Cleaning and care 6.1.1 Safety advices  Before you start to clean and care switch off the appliance and disconnect it from the mains.
  • Page 17 Maintenance 6.1.4 Special cleaning hints Please find below some special cleaning tips for this specific unit:  Lamps: To be cleaned only with soft paper or cloth and alcohol.  Glass: Tip the cuved front glass to clean the inside. Remove dust and dirt from the glass surface with soft cloth to avoid scratches.
  • Page 18: Trouble Shooting

    If your Hot Cabinet does not work satisfactorily we would like to give a first help with the following checklist. Only after checking these points you should contact: a) your responsible service partner b) directly the company: UBERT GASTROTECHNIK GMBH Werk II Gewerbegebiet Nord Vennekenweg 17 46348 Raesfeld Tel.:02865 / 602-226...
  • Page 19: Wiring Diagrams

    Maintenance 6.3 Wiring Diagrams 6.3.1 HT 700 230V, 1/N, 50Hz 6.3.2 HT 700 DB 230V, 1/N, 50Hz  TopLineUserManualHT.docx printed: 02/2015 Subject to change!
  • Page 20 Maintenance 6.3.3 HT 1100 400V, 3/N, 50Hz 6.3.4 HT 1100 DB 400V, 3/N, 50Hz  TopLineUserManualHT.docx printed: 02/2015 Subject to change!
  • Page 21 Maintenance 6.3.5 HT 1400 400V, 3/N, 50Hz 6.3.6 HT 1400 DB 400V, 3/N, 50Hz  TopLineUserManualHT.docx printed: 02/2015 Subject to change!
  • Page 22 Maintenance 6.3.7 HT 700-2 (UL) 230V, 1/N, 50Hz 6.3.8 HT 700-2 DB (UL) 230V, 1/N, 50Hz  TopLineUserManualHT.docx printed: 02/2015 Subject to change!
  • Page 23 Maintenance 6.3.9 HT 1100-2 (UL) 400V, 3/N, 50Hz 6.3.10 HT 1100-2 DB (UL) 400V, 3/N, 50Hz  TopLineUserManualHT.docx printed: 02/2015 Subject to change!
  • Page 24 Maintenance 6.3.11 HT 1400-2 (UL) 400V, 3/N, 50Hz 6.3.12 HT 1400-2 DB (UL) 400V, 3/N, 50Hz  TopLineUserManualHT.docx printed: 02/2015 Subject to change!
  • Page 25: Spare Parts

    Maintenance 6.4 Spare Parts Defect parts are to be replaced only by original spare parts of UBERT GASTROTECHNIK GMBH; the replacement is to be carried out only by their service personal or by your authorized Service companies. If you do not observe this note or...
  • Page 26 Maintenance 6.4.2 Spare Parts List HT700 / HT700DB Pos. Description Part No. Amount front glass, assy 121060 glass holder for side glass, above 121042 reflector 120531 halogen lamp socket 340412 halogen lamp (100W) 340623 1/1 GN-basin 401107 intermediate web 120518 heating element (1300W / 230V) 343121 glass support...
  • Page 27 Maintenance 6.4.3 Spare Parts List HT1100 / HT1100DB Pos. Description Part No. Amount front glass, assy 121061 glass holder for side glass, above 121042 reflector 120563 halogen lamp socket 340412 halogen lamp (100W) 340623 1/1 GN-basin 401107 intermediate web 120550 heating element (1300W / 230V) 343121 glass support...
  • Page 28 Maintenance  TopLineUserManualHT.docx printed: 02/2015 Subject to change!
  • Page 29 Maintenance 6.4.4 Spare Parts List HT1400 / HT1400DB Pos. Description Part No. Amount front glass, assy 121062 glass holder for side glass, above 121042 reflector 120593 halogen lamp socket 340412 halogen lamp (100W) 340623 1/1 GN-basin 401107 intermediate web 120580 heating element (1300W / 230V) 343121 glass support...
  • Page 30 Maintenance  TopLineUserManualHT.docx printed: 02/2015 Subject to change!
  • Page 31 Maintenance 6.4.5 Spare Parts List contactor (ABB) fuse socket fuse 5A 342409: HT 1100 (-DB) 335090: HT 700-2 (-DB) 335091: HT 700-2 (-DB) 342409: HT 1400 (-DB) 335090: HT 1100-2 (-DB) 335091: HT 1100-2 (-DB) 335090: HT 1400-2 (-DB) 335091: HT 1400-2 (-DB) terminal block end cap for terminal block ballast...
  • Page 32: Declaration Of Conformity

    Maintenance 6.5 Declaration Of Conformity  TopLineUserManualHT.docx printed: 02/2015 Subject to change!

Table of Contents