Table of Contents
loading

Summary of Contents for Lincoln Electric PRISM AD2458-1

  • Page 1 Operator’s Manual PRISM EXHAUST HOOD ® For use with machines having Code Numbers: AD2458-1 thru AD2458-46 Register your machine: www.lincolnelectric.com/register Authorized Service and Distributor Locator: www.lincolnelectric.com/locator Save for future reference Date Purchased Code: (ex: 10859) Serial: (ex: U1060512345) IM10575 | Issue D ate May-21 ©...
  • Page 2 THANK YOU FOR SELECTING A QUALITY PRODUCT BY KEEP YOUR HEAD OUT OF THE FUMES. DON’T get too close to the arc. LINCOLN ELEC TRIC. Use corrective lenses if necessary to stay a reasonable distance away from the arc. READ and obey the Safety Data PLEASE EXAMINE CARTON AND EQUIPMENT FOR Sheet (SDS) and the warning label DAMAGE IMMEDIATELY...
  • Page 3: Section A: Warnings

    W117.2. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 2.d. All welders should use the following procedures in order to St. Clair Avenue, Cleveland, Ohio 44117-1199.
  • Page 4: Electric Shock Can Kill

    SAFETY ELECTRIC SHOCK ARC RAYS CAN BURN. CAN KILL. 3.a. The electrode and work (or ground) circuits are 4.a. Use a shield with the proper filter and cover plates to protect your electrically “hot” when the welder is on. Do eyes from sparks and the rays of the arc when welding or not touch these “hot”...
  • Page 5 SAFETY WELDING AND CUTTING CYLINDER MAY EXPLODE IF SPARKS CAN CAUSE DAMAGED. FIRE OR EXPLOSION. 7.a. Use only compressed gas cylinders containing the correct shielding gas for the process used 6.a. Remove fire hazards from the welding area. If and properly operating regulators designed for this is not possible, cover them to prevent the welding sparks the gas and pressure used.
  • Page 6 SAFETY As a rule of thumb, for many mild steel electrode, if the air is visibly Ventilation clear and you are comfortable, then the ventilation is generally There are many methods which can be selected by the user to adequate for your work. The most accurate way to determine if the provide adequate ventilation for the specific application.
  • Page 7 TLV and PEL values are as of October 2013. Always check Safety and 313 of the Emergency Planning and Community Right- Data Sheet (SDS) with product or on the Lincoln Electric website at to-Know Act of 1986 and of 40CFR 370 and 372.
  • Page 8 PRISM ® EXHAUST HOOD TABLE OF CONTENTS...
  • Page 9: Technical Specifications

    PRISM ® EXHAUST HOOD INSTALLATION TECHNICAL SPECIFICATIONS PRISM ® EXHAUST HOOD HOOD SIZE MINIMUM HOOD SIZE 6.5 FT X 5.5 FT MAXIMUM HOOD SIZE 7.5 FT X 20 FT CLEAR POLYCARBONATE ROOFING Air Flow(CFM) WIDTH LENGTH Area NUMBER WEIGHT 1 AIR 2 AIR 3 AIR Part Number...
  • Page 10: General Description

    Box with required hardware and double sided tape for Multi F. Outlet flange wall Polycarbonate assembly. G. End Plate Instruction manual and Lincoln Electric logo for branding H. Baffle Plate Shipment comes with pre-assembled width sections (6.5 ft or 7.5 ft) I.
  • Page 11: Mounting Possibilities

    PRISM ® EXHAUST HOOD INSTALLATION NOTE: The best way to assemble a Prism ® Exhaust Hood is to place a stack of pallets under each corner of the hood and MOUNTING POSSIBILITIES one or two additional stacks under the loose ends of the cross-profiles.
  • Page 12 PRISM ® EXHAUST HOOD INSTALLATION...
  • Page 13 PRISM ® EXHAUST HOOD INSTALLATION...
  • Page 14 PRISM ® EXHAUST HOOD INSTALLATION...
  • Page 15 PRISM ® EXHAUST HOOD INSTALLATION...
  • Page 16 PRISM ® EXHAUST HOOD INSTALLATION...
  • Page 17 PRISM ® EXHAUST HOOD INSTALLATION...
  • Page 18: Proceed As Follows

    PRISM ® EXHAUST HOOD INSTALLATION TO MOUNT THE PRISM EXHAUST HOOD ® ROOF PANEL ASSEMBLY PROCEED AS FOLLOWS: 3. Outlet roof panel has to be assembled to center of the outer ATTENTION frame. Emboss is provided at the center of the frame for easy identification.
  • Page 19 PRISM ® EXHAUST HOOD INSTALLATION ROOF PANEL ASSEMBLY: MULTI WALL ROOF PANEL ASSEMBLY: GALVANIZED SHEET POLYCARBONATE METAL Film Removal and Taping 1. Adjust the length (if needed) using a Jig saw. Polycarbonate sheets and panels can be cut with fine- toothed (8-12 teeth/inch) circular, jig, table, or band saw.
  • Page 20 PRISM ® EXHAUST HOOD INSTALLATION 5. Curtain brackets are used to connect the curtains between MOUNTING THE HOOD SIDE BY SIDE FOR the two hoods. It acts as a bridge between the hoods for DUAL AND TRIPLE HOOD curtain mounting. 6.
  • Page 21 PRISM ® EXHAUST HOOD INSTALLATION INSTALLING ON EXISTING CELL WALL/ FRAME ASSEMBLY ON THE TOP OF THE CELL: FENCES: 1. Assemble the pre-assembled sections on top of the struts. NOTE: Before installing, the required height for the hood must See Figure A.19. be determined.
  • Page 22 PRISM ® EXHAUST HOOD INSTALLATION 3. For remaining roof panel assembly instructions refer previous page of the manual for roof panel assembly. See Figure A.15. FIGURE – A.21 4. Mount the strut channel at four corners using corner brackets. Secure it with 1/4" self drilling screws Qty-6.
  • Page 23 PRISM ® EXHAUST HOOD INSTALLATION FIGURE – A.23 STAND ALONE HOOD USING THE LEG KITS: FIGURE – A.24 1. Lift the hood, preferably using a fork-lift truck. 2. For Large Prism ® Exhaust Hood: use two fork-lift trucks. 3. Drill out the embosses at corner brackets using 7/16" drill bits.
  • Page 24 PRISM ® EXHAUST HOOD INSTALLATION HUNG FROM CEILING USING HOOD HANGING KIT: FIGURE – A.28 ATTENTION: For a hanging mounted con guration, check that the roof is strong enough. Weights of Prism Exhaust ® Fume Hoods are listed in the M27517 tables published on the pages A.4 to A.6.
  • Page 25: Curtain Installation

    See Figure 29. FIGURE - A.29 4. Align and attach the branding Lincoln Electric Logo on the front center and any visible (right or left) side of the hood. See Figure A.30. FIGURE - A.30...
  • Page 26 PRISM ® EXHAUST HOOD INSTALLATION INSTRUCTIONS TO TRIM THE HOOD LENGTHWISE: - Dismantle the hood width section as shown. - Cut the two adjacent frames and Multi wall Polycarbonate/sheet metal to the required size. - Reinsert the width section and secure it with self drilling screws as per the instructions above.
  • Page 27: Operation

    PRISM ® EXHAUST HOOD OPERATION OPERATION The Prism ® Exhaust Hood is placed over the working area and has to be connected to an external extraction/filtration system. The square baf˜e plate works as a spark arrestor. The extracted air leaves the hood through one or two connection ˜anges mounted on top.
  • Page 28: Options And Accessories

    PRISM ® EXHAUST HOOD ACCESSORIES OPTIONS AND ACCESSORIES The following products can be obtained as an option and/or accessory: Leg Kit Leg kits are used for mounting the stand alone hood. The height can be adjusted based on the requirement. The kit includes cross braces and mounting bracket.
  • Page 29: Periodic Maintenance

    PRISM ® EXHAUST HOOD MAINTENANCE SERVICE, MAINTENANCE ATTENTION AND REPAIRS Always wear a respirator and gloves during service and maintenance Observe the maintenance intervals given in this manual. Overdue work. Industrial vacuum cleaner maintenance can lead to high costs for repair and revisions and used during service and maintenance can render the guarantee null and void.
  • Page 30 PRISM ® EXHAUST HOOD MAINTENANCE TABLE D.1 – MAINTENANCE SCHEDULE Frequency Every 12 months Every 3-6 month Light use Every 9 months Normal use Every 3 months Heavy use Every 1-2 months Every 6 months Component Action Outer frame profiles, roof Check outside of the hood and clean it with a panels nonaggressive detergent.
  • Page 31 Do not touch electrically live parts or Keep flammable materials away. Wear eye, ear and body protection. electrode with skin or wet clothing. WARNING Insulate yourself from work and ground. Spanish No toque las partes o los electrodos Mantenga el material combustible Protéjase los ojos, los oídos y el AVISO DE bajo carga con la piel o ropa mojada.
  • Page 32 Keep your head out of fumes. Turn power off before servicing. Do not operate with panel open or Use ventilation or exhaust to remove guards off. WARNING fumes from breathing zone. Los humos fuera de la zona de res- Spanish Desconectar el cable de alimentación No operar con panel abierto o AVISO DE...
  • Page 33 We respond to our customers based on the best information in our possession at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such information or advice.