Download Print this page

BT SIP Quick Install Manual page 4

Access control system

Advertisement

In strictest confidence
PCB elements
1 ( SW2)
2
3 ( NO/NC Jumper)
4
5
6-Ethernet
5VD (5V DC)
SEN 1/2 (Sensor 1/2*)
REL 1/2 (Relay 1/2)
Audio Out*
1.3 Help and assistance
Prior to calling, please check the following:
Issued by: North Supply Ltd
Issue no: BTDE0202BB02
Date: July 2019
2. The default IP Door Phone IP address is 10.10.10.6 and it is configured as
'Static' IP address.
3. The default web-programming Administrator credentials are:
3.1. User name: 'admin' – For Administrator management level and 'user' –
for User management level.
3.2. Default Password: 1234 for both management levels.
Description
Factory Default Settings switch:
'Normal' – Door Phone normal working position 'Default' – Set to
default procedure mode
Hardware Reset ( Cold Reset Switch)
Relay 1 and Relay 2 Normally Open and Normally Close status jumper.
Closed Central Pin (2) + 'NO'- (1) pin means the 'Normally open' mode.
Closed Central Pin (2) + 'NC' - (3) pin means the 'Normally Close' mode
Note: Relay 2 works in Normally Open (NO) mode only
Microphone Connector
Speaker Connector
POE+/LAN connection
External power supply 5VDC 2A input (if no POE+ applied).
Draw attention on connection polarity: +5V and GND marked on PCB
(Fiure 6-2)
The External Power Supply is not included in standard IP394X package
Door status detector.
Also can be used as external Switch button connection (Chapter 8.3).
Note:
The External Switch button can be used for manual door opening
usually labelled N/O and C or CMN and Make on the terminals
Support 30VDC 2A
Internal relays Normally Open and Normally Close status depends on
JP1 jumper position.
Reserved for future release
1. You know the extension number the door unit is connect to on the PBX.
2. You can dial the door unit and generate DTMF tones from the PBX.
3. The unit is powered by POE+ or the supplied power supply.
4. Check you are using the correct door release type relative to the power
supply i.e. DC release as standard.
5. To view the full install guide please refer to the CD included with the unit.
BT SIP Access Control System Quick Install Guide
Page 4 of 6