HMS EZ-SCENE ALC LIGHTING INTERFACE
ALC controls may also be connected to the EZ-Scene Interface
via a Branch Hub (part nos. 364677-01 or 364736-01) as shown
in Figure 5. Each Branch Hub supports an additional 500 ft. of
category 3/5/5E branch communication cable in addition to
providing a more structured installation. The HMS Controller
can provide 12VDC power to each Branch Hub.
Figure 5. Branch Hub Connection
Innovations in Home Living.
301 Fulling Mill Road, Suite G
©Copyright 2005 by OnQ Technologies, Inc All Rights Reserved.
Middletown, PA 17057
www.onqhome.com
(800)-321-2343
Note: Do not exceed the HMS controller's device load limit.
Consult the HMS controller's installation manual for device
load ratings.
Figure 6 illustrates connection of the RF Remote Control
Receiver (part no. 364697-01) to the EZ-Scene Interface's
inputs. The HMS Controller can provide 12VDC power to the
RF Remote Control Receiver.
configured to the normally open position. All common points
should be tied to circuit ground (GND).
Note: White/Green conductor terminates to R2 COMMON
AND R4 COMMON. Green conductor terminates to R1
COMMON AND R3 COMMON.