Download Print this page

On-Q HMS EZ-Scene ALC Instruction/Installation Sheet

Lighting interface

Advertisement

Quick Links

INSTRUCTION/INSTALLATION SHEET
HMS EZ-SCENE ALC LIGHTING INTERFACE
Figure 1. HMS EZ-Scene ALC Lighting Interface
1. Introduction
The part no. 364806 HMS EZ-Scene ALC Lighting Interface
enables any On-Q HMS Controller or HAI OMNI controller to
control On-Q's Advanced Lighting Controls. Additionally, the
expansion module provides local lighting scene programming
capability. EZ-Scene programming allows ALC 4-Button Scene
Switches and RF Remote Controls to learn the lighting level
settings of ALC Dimmers, Relay Switches and Non-Dimming
controls independent of the HMS Controller.
The part no. 364806-01 1-Branch HMS EZ-Scene ALC
Lighting Interface provides control of up to 31 ALC controls.
The part no. 364806-02 4-Branch HMS EZ-Scene ALC
Lighting Interface provides control of up to 124 ALC controls.
Both expansion module part nos. support a total of 64 EZ-Scene
local lighting scene programs.
The On-Q HMS Model 800 controller provides direct control
of up to 16 ALC controls on branch no. 1. The HMS Model
950 controller provides direct control of 62 ALC controls on
branch nos. 1 and 2. The HMS Model 1100 controller provides
direct control of up to 248 ALC switches using up to two part
no. 364806-02 EZ-Scene ALC Lighting Interface modules.
Innovations in Home Living.
301 Fulling Mill Road, Suite G
©Copyright 2005 by OnQ Technologies, Inc All Rights Reserved.
Middletown, PA 17057
www.onqhome.com
(800)-321-2343
2. Installation
Note: If other expansion modules are connected to the HMS
controller, the EZ-Scene ALC Lighting Interface must be
installed first, that is directly above the HMS controller.
1. Remove 4 6/32 x 1/4 Phillips screws indicated as "A" in
Figure 2. Replace the screws with the 4 supplied 6/32 x 1/2
male/female Hex Standoffs. Retain screws for future step.
2. Connect supplied cable to 20 pin connector on controller
indicated as "B" in Figure 2.
3. Align the interface PCB with the hex standoffs and secure
with the 4 screws removed in step 1.
4. Connect opposite end of supplied cable to the 20 pin
connector on the interface PCB indicated as "C" in Figure 2.
5. Ensure that the address jumper indicated as "D" in Figure 2,
is set to a unique address. Factory setting is address no. 2.
Note: This example is for the HMS 800. For Models 950 and
1100 mounting is to the right side of the controller, the same
procedure should be followed.
Figure 2. HMS EZ-Scene ALC Lighting Interface Mounting
IS-0311 REV. A
Page 1 of 4

Advertisement

loading

Summary of Contents for On-Q HMS EZ-Scene ALC

  • Page 1 Figure 1. HMS EZ-Scene ALC Lighting Interface procedure should be followed. 1. Introduction The part no. 364806 HMS EZ-Scene ALC Lighting Interface enables any On-Q HMS Controller or HAI OMNI controller to control On-Q’s Advanced Lighting Controls. Additionally, the expansion module provides local lighting scene programming capability.
  • Page 2 Correct polarity must be maintained. Inputs 1 - 4, indicated as “B” in Figure 3, provide terminal connections for On-Q’s part no. 364697-01 RF Remote Control Receiver or other external device outputs. These four logic-level inputs simulate the four buttons of an ALC Scene Switch. These inputs are referred to as Virtual Scene Switch Inputs.
  • Page 3 INSTRUCTION/INSTALLATION SHEET HMS EZ-SCENE ALC LIGHTING INTERFACE IS-0311 REV. A ALC controls may also be connected to the EZ-Scene Interface Note: Do not exceed the HMS controller’s device load limit. via a Branch Hub (part nos. 364677-01 or 364736-01) as shown Consult the HMS controller’s installation manual for device...
  • Page 4 Warranty Note: Up to two EZ-Scene Interfaces may be connected to an On-Q warrants to the end-user, each new HMS EZ-Scene ALC HMS Model 1100 controller, however local lighting scene Lighting Interface to be free of defects in materials or...