English
User Manual
Technical Parameters
multisys D4-IGW-1
multimax D4-IGW-1
You can find the instructions for your KBR
device at our download center.
https://www.kbr.de/de/dienstleistungen/
download-center

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the multisys D4-IGW-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for KBR multisys D4-IGW-1

  • Page 1 User Manual Technical Parameters multisys D4-IGW-1 multimax D4-IGW-1 You can find the instructions for your KBR System English device at our download center. https://www.kbr.de/de/dienstleistungen/ download-center...
  • Page 2 Table of Contents KBR Kompensationsanlagenbau GmbH does not accept any liability for any loss or damage resulting from printing errors in or changes to this manual. In addition, KBR Kompensationsanlagenbau GmbH does not accept any liability for any loss or damage caused by defective devices or devices manipulated by the user.
  • Page 3: Table Of Contents

    Table of Contents Table of Contents Introduction ............................4 User Manual ............................4 Safety Keys ............................5 Safety Notes ............................6 Product Liability ..........................7 Scope of Delivery ..........................7 Disposal .............................. 7 Overvoltage and Lightning Protection ................... 7 Range of Functions ......................... 8 Range of Functions multimax D4-IGW-1 ................
  • Page 4: Introduction

    Introduction Introduction Thank you for choosing this KBR quality product. To become familiar with the operation and programming of the device and to use the full range of functions of this high-quality product at all times, you should read this user manual carefully.
  • Page 5: Safety Keys

    Introduction Safety Keys This manual contains instructions that you must follow for your personal safety and to avoid material damage. These instructions are identified by a warning sign or information symbol, depending on the degree of hazard they warn about. DANGEROUS VOLTAGE „Warning“...
  • Page 6: Safety Notes

    Introduction Safety Notes In order to prevent operating errors, device operation is kept as simple as possible. This will enable you to start your device up quickly. It is in your own interest to read the following safety instructions carefully. DANGEROUS VOLTAGE The applicable DIN/VDE regulations must be observed during installation! Connection to the mains, commissioning and operation of the device may only be carried...
  • Page 7: Product Liability

    Each device undergoes a long-term test before delivery. With regard to product liability, please see our general terms and conditions for electronic devices, which you can read at www.kbr.de. The warranty on device characteristics only applies if the device is operated in...
  • Page 8: Range Of Functions

    Range of Functions Range of Functions The device is a universal minicomputer based on the Raspberry 3 Compute Module (CM3). It can be installed in standard switchgear cabinets and has an integrated power supply unit for a 230V power connection. Depending on the application intended, a specific software image will be installed by the manufacturer.
  • Page 9: Installation

    Installation Installation This chapter describes: „Mounting the device“  „3.2 Connection Diagram“ on page 10  „3.3 Terminal Assignment“ on page 12  Device assembly The housing of the D4-IGW-1 has been designed for switchgear cabinet mounting on a 35 mm DIN rail. The module is snapped on the mounted DIN rail. CAUTION The device control voltage must be secured with a back-up fuse on site.
  • Page 10: Connection Diagram

    Installation Connection Diagram Figure 1: Connection diagram Figure 2: Connections on top V1.00...
  • Page 11 Installation Figure 3: Connections on bottom Figure 4: Front view V1.00...
  • Page 12: Terminal Assignment

    Terminals 90 (ground), RS485 Communication Port (e.g. KBR eBus) 91 (A) and 92 (B) A Serial Port 1. Module OUT For communication with the KBR expansion modules. Maximum Output Power: 2W Network Connection for Ethernet TCP Ethernet Universal Serial Bus (USB 2.0)
  • Page 13: Network Communication

    Network Communication Network Communication The standard for the D4-IGW-4 is a dynamic address for a DHCP server available in the network. If this process fails, a “fallback” address will automatically be set, which is as follows: IP: 192.168.0.2 Subnet mask: 255.255.255.0 If a monitor is connected to the device, the IP address will be displayed during booting.
  • Page 14: Configure Network Settings

    Configure Network Settings Configure Network Settings In exceptional cases, it may be necessary to manually adjust the network configuration. There are essentially two options for this: 1. Online 2. Offline Online In order to be able to modify the settings during continuous operation, an SSH connec- tion to the device must be established - see “Establish SSH Connection.
  • Page 15: Offline

    Navigate to the following file using a file ex- plorer and open it with Editor (preferably the Notepad++ editor): KBR\dhcpcd_template.conf The section to be edited is at the end of file.
  • Page 16: Hardware Reset

    Using a standard SSH client, a secure connection can be established to the D4-IGW-4 - for example, using Kitty or Putty under Windows. The host name or even the IP address given can be used as the target (standard SSH port => 22) Login terminal console User: kbr Password: kbradmin V1.00...
  • Page 17: Technical Data

    RS 485 interface Protocol and speed depend on software configu- ration Module bus Serial RS 485 (RJ12) for ready-made KBR system cable (6- interface interface pin modular cable, unshielded), max. length 30 m if placed suitably. Maximum output power: 2W USB inter- Serial USB 2.0 Port...
  • Page 18: Surrounding Conditions / Electrical Safety

    Technical Data 8.1.5 Surrounding Conditions / Electrical Safety Surrounding Standards DIN EN 60721-3-3/A2: 1997-07; conditions 3K5+3Z11; (IEC721-3-3; 3K5+3Z11) Operating temperature K55 (-5 °C …. +55 °C) Air humidity 5 % … 95 %, non-condensing Storage temperature K55 (-25°C …. +70°C) Operating height 0…2,000 m above sea level Electrical...
  • Page 19 Notes V1.00...
  • Page 20 KBR Kompensationsanlagenbau GmbH Am Kiefernschlag 7 T +49 (0) 9122 6373 - 0 www.kbr.de D-91126 Schwabach F +49 (0) 9122 6373 - 83 Germany E info @ kbr.de...