RTI MAS-2 User Manual

Non-invasive tube current probe for the rti meter

Advertisement

Quick Links

Non-invasive Tube Current Probe
User's Manual - English - Version 2019.12A
RTI Group AB reserves all rights to make changes in the RTI MAS-2 and the information
in this document w ithout prior notice.
RTI Electronics AB assumes no responsibility for any errors or consequential damages
that may result from the use or misinterpretation of any information contained in this
document.
Copyright © 2003-2019 by RTI Group AB. All rights reserved.
Content of this document may not be reproduced for any other purpose than supporting
the use of the product w ithout prior permission from RTI.
Contact Information -
World Headquarters
RTI Group AB
Flöjelbergsgatan 8 C
SE-431 37 MÖLNDAL
Sweden
Phone: Int. +46 31 7463600
Fax:
Int. +46 31 270573
E-mail
Sales: sales@rtigroup.com
Support: support@rtigroup.com
Service: service@rtigroup.com
Web: http://www.rtigroup.com
RTI MAS-2
for the RTI Meter
Contact Information -
US Office
RTI Electronics Inc.
33 Jacksonville Road, Bldg. 1,
Towaco, NJ 07082
USA
Phone: 1-800-222-7537 (Toll free)
Int. +1-973-439-0242
Fax:
Int. 1-973-439-0248
E-mail
Sales: sales.us@rtigroup.com
Support: support.us@rtigroup.com
Service: service.us@rtigroup.com
Web: http://www.rtigroup.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAS-2 and is the answer not in the manual?

Questions and answers

Summary of Contents for RTI MAS-2

  • Page 1 RTI Meter User's Manual - English - Version 2019.12A RTI Group AB reserves all rights to make changes in the RTI MAS-2 and the information in this document w ithout prior notice. RTI Electronics AB assumes no responsibility for any errors or consequential damages that may result from the use or misinterpretation of any information contained in this document.
  • Page 2 Contents Intended Use of the RTI MAS-2 Together w ith instruments from RTI Group AB it is to be used for independent service and quality control, as w ell as measurements of kerma, kerma rate, kVp, tube current, exposure time, luminance, and illuminance w ithin limitations stated below .
  • Page 3: Table Of Contents

    ..................... 7 ......................8 Index Note! For a full description of the RTI Meter, see the RTI Meter Reference Manual. That Manual can be found on the Product USB or be downloaded from RTI's website (www.rtigroup.com). 2019.12A RTI M AS-2 User's M anual...
  • Page 4: Introduction General

    INTRODUCTION General The RTI MAS-2 is an adapter cable together with a current clamp probe for use with RTI Meter X-ray multimeter. It provides a non-invasive way to measure tube current (mA) and tube charge (mAs) on X-ray equipment. The current probe is simply clamped on the high voltage lead and is then ready for measurements.
  • Page 5: Function And Connection

    The clamp probe is powered on with the range switch. Connection of the RTI MAS-2 The RTI MAS-2 is connected to the detector input of the RTI Meter using the round Lemo connector. The clamp probe is connected using the two banana connectors in the other end of the cable.
  • Page 6: Measurements

    (See Settings in the RTI Meter manual). SAFETY PRECAUTIONS General Rules • Do NOT use the RTI MAS-2 on a circuit with a voltage of higher than 600 V AC. • Do NOT remove the battery compartment cover when attempting to measure current.
  • Page 7: Specifications

    SPECIFICATIONS For PROVA 15 specifications see the "PROVA 15 User's Manual" General Specifications for RTI MAS-2 Specifications are valid after a warm-up time of one minute and presuming reference conditions. All specifications together with the clamp probe probe unless otherwise stated.
  • Page 8: Index

    - A - Accuracy - B - Battery Battery Lif e - C - Connection of the RTI MAS-2 - F - Function of the RTI MAS-2 - I - Inaccuracy Initial Of f set Adjustment Procedure - M -...
  • Page 9 Notes Notes 2019.12A RTI M AS-2 User's M anual...

Table of Contents