Laundry Room Survey - DEMA ATLAS 844P Series Manual

Laundry control
Table of Contents

Advertisement

PLEASE READ THE NOTE BELOW AND CLEAR ALL PROGRAMS ON INITIAL USAGE OF
THIS PRODUCT.
ON THE VERY FIRST USAGE OF THE EDSM (NEW OUT OF THE BOX) CONNECT THE
EDSM TO THE LAUNDRY SYSTEM AS DESCRIBED ABOVE. POWER IT UP, ENTER
PROGRAMMING AND PROCEED TO THE UTILITY MENU. "CLEAR ALL PROGRAMS"
BEFORE USING THE EDSM FOR THE FIRST TIME. THIS WILL ONLY NEED TO BE DONE
AT INITIAL USAGE. IT IS NOT NECESSARY TO CLEAR ALL PROGRAMS AFTER THE
INITIAL CLEARING.
UTILITY MENU.
OPTIONS AND HOW TO "CLEAR ALL PROGRAMS."
ALWAYS SEND A PROGRAM FILE FROM AN EDSM TO EVERY ATLAS THAT IS BEING
SETUP. THE EDSM USED TO SEND THE FILE MUST HAVE BEEN CLEARED AT INITIAL
USAGE AS DESCRIBED IN PREVIOUS PARAGRAPH. THE PROGRAM FILE CAN BE A
FILE THAT CONSIST OF NO SETUP OR A PROGRAM FILE THAT WAS USED ON A
PREVIOUS SETUP.

Laundry Room Survey

A complete survey of the laundry room or site installation should be completed in advance of starting the
Laundry Master installation.
1. Locate the power connection points on the laundry machine. The main power to the Laundry
Master must either be 120V or 230V 50/60Hz (+10%/-15% for voltage is acceptable).
2. Select a location to mount the Laundry Master enclosure on a wall that will allow access to the
chemical product containers and the chemical product feeds points on the laundry machine. The
Laundry Master should be kept away from moisture releasing machinery and from water being
splashed on the unit.
3. Mount the Laundry Master on a wall by use of appropriate screws and wall anchors.
4. Select a location to mount the Signal Transfer Unit (STU). The STU should be mounted close to,
or on, or possibly inside the laundry machine. The STU will need to be wired to the various
trigger signal sources on the machine. The trigger wires that are coming out of the STU are 36
inches in length and are used to receive the trigger signals. The STU can be mounted by use of the
self-adhesive Velcro that is included in the hook up kit. Keep in mind that the STU is wired to the
IQ-85 via the supplied communication cable.
I-907
Rev. C-33371
DEMA ATLAS 844P
LAUNDRY CONTROL
****** IMPORTANT ******
SEE PROGRAMMING SECTION BELOW TO NAVIGATE TO
PAGES 9 AND 10 OF THIS INSTRUCTION MANUAL SHOW THE
SERIES
Page 3 of 17