SAFETY WARNINGS CONFORM USE The materials are built based on current technical state-of-the-art and acknowledged safety rules. Nonetheless, dangers for the user or others as well as damages to material or property could occur following an improper use. Any different use is considered im- proper.The manufacturing company will not be liable for damages caused by improper use;...
INSTALLATION METHOD ATTENTION: THE EVO SOLAR COVER CAN ONLY BE INSTALLED WITH SO- LAR COLLECTORS H1T AND H1TX Assembly of plates and backplates on the collector’s frame. (Fig. 2 and Fig. 3) Right upper plate Left upper backplate Fig. 1 Left lower backplate Left lower backplate...
Page 5
Roller-spring introduction on lower plate and backplate. Fig. 4 ATTENTION Insert the safety pin to lock the spring. Fig. 5...
Page 6
Introduction of cover and motor on upper plate and backplate. Vite DIN 912 A2 M8 x Fig. 6 Before the subsequent step, connect the control unit (see attachment A, page 8) and manually lower the cover against the lower end run (covered collector).
Page 7
Roller-spring loading and fastening of cover tensioning belts. x 5/6 MODEL H1T Make 5/6 rotations to perfectly load the roller-spring. MODEL H1TX Make 5/6 rotations to perfectly load the roller-spring. Fig. 8 ATTENTION keep the loaded roller- spring locked during fastening of the tensio- ning belts.
Page 8
(fig. 10a-b-c) and upper-lower (fig. 10d) protective guards assembly. Fig. 10 The cover is now assembled. Make the electric connection. If lateral guards holes don’ t metch with backplate and plate holes, please drill guards and make a slot.
CONTROL UNIT ATTACHMENT The board is housed in a ip64 water-tight container; connect the motor and temperature probe to this board. A green LED (voltage present) and a red LED indicating the operating mode, light-up when the con- trol unit is switched on: √...
Page 10
WIRING DIAGRAM Centenda Model Connect the electric motor earth cable directly to power supply earth cable Not included and optional wiring Clamps Description 1 - 3 230V/50Hz Power supply 2 - 4 Do not connect Common motor (BLUE wire) Cover opening motor (BROWN wire) Cover closing motor (BLACK wire) Switch input (Cover opening) OPTIONAL-NOT INCLUDED...
Page 11
MULTI-COVER WIRING DIAGRAM Centenda 4 Model Connect the electric motor earth cable directly to power supply earth cable CONNECTION WITH 4 MOTOR CONTROL UNIT Not included and optional wiring Clamps Description 1 4 7 10 Cover opening M1 M2 M3 M4 (brown) 2 5 8 11 Common motor M1 M2 M3 M4 (blue) 3 6 9 12 Cover closing M1 M2 M3 M4 (black) 13 14 15 Additional board wiring (Already wired)
Page 12
GRAPHIC DESCRIPTION Centenda Model Aut/Man Switch Deep Switch SW1 Adjustment buttons 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Probe input 230V 50Hz Cover motor inputs Power-Supply External adjustment switches Aut/Man external switch Not included and optional wiring...
Page 13
GRAPHIC DESCRIPTION Centenda 4 Model Aut/Man Switch Control Switch Deep Switch SW1 Probe Input 1 2 3 4 5 6 7 8 9 10 11 12 230V 50Hz Power Supply Motor 3 Motor 4 Motor 1 Motor 2 Aut/Man external switch External adjustment switches Not included and optional wiring...
Page 14
CONTROL UNIT ADJUSTMENT AUTOMATIC/MANUAL SWITCH: Switch positioning in manual: the motor is moved using the buttons; the red LED in the board flashes. Switch positioning in automatic: permanent red LED, the motor cannot be moved using the buttons. Attention: the buttons are of “dead man” type, if kept pressed the mo- tor moves, released it stops.
SOFTWARE FEATURES SOFTWARE FEATURES - SOFTWARE FEATURES 1. The control unit closes the cover and checks effective drop in temperature when the set temperature, as in diagram 1 in previous page, is exceeded. 2. The end run stop system, adjusted on 230V motor 3.
Page 16
END RUN ADJUSTMENT END RUN ADJUSTMENT - END RUN ADJUSTMENT ATTENTION! The following procedure must be implemented ONLY IF set adjustment is incorrect. IT IS ESSENTIAL to be able to stop movement at any time during the end run adjustment to avoid damaging property, persons, animals and the device.
Page 17
LOWER END RUN LOWER END RUN - LOWER END RUN THE COLLECTOR REMAINS TOTALLY OR PARTIALLY UNCOVERED: If the solar collector is not totally covered by the cover, follow the instructions below: • Place the AUT/MAN diverter on Manual. • ROTATE THE REGULATOR CLOCKWISE (+). •...
Page 18
UPPER END RUN UPPER END RUN - UPPER END RUN THE COLLECTOR IS TOTALLY OR PARTIALLY COVERED: If the solar collector is not totally uncovered but partial- ly so by the cover, follow the instructions below: • PLACE THE AUT/MAN DIVERTER ON MANUAL. •...