NEM Lamp Memory System for Long Distances and Elevators
IF-DA-NLD and IE-JA-NLD Sub Stations
The NEM Long Distance Lamp Memory System is designed for communication with remote
locations up to 4,000' away, or to each elevator in a building. Sub stations are available in
surface or flush mount styles, and require a separate circuit board (PC-359B) to be added for
the call-in function. Three wires are required to each sub station.
WIRING DIAGRAM:
PC-359B
IE-JA-NLD
1
2
1
2
2
3
4
Blk
5
Blk
6
7
3
7
7
7
8
9
Individual Components for NEM-LD System:
NEM-n-LD
Master station (10, 20, 30, 40-station) for Long Distance
IE-JA-NLD
Flush mount long distance sub with stainless steel cover
IF-DA-NLD
Surface mount long distance sub, brown plastic
PC-359B
Call holding circuit board for sub station, mounted externally
PS-2410A
24V DC Power Supply (for 10 and 20 station masters)
PS-24E
24V DC, 2A Power Supply (for 30 and 40 station masters)
SUB STATION MOUNTING:
IE-JA-NLD: 2-gang electrical box
IF-DA-NLD: Surface mounts to 1-gang box
NEM-LD
NEM-n-LD Master Station
- INSTRUCTIONS -
NEM-20-LD
1
2
3
~
20
E
H
PS-2410A
+
or
-
PS-24E
NEM-LD TERMINAL DEFINITIONS:
+
Positive 24V DC
-
Negative
1~40
Station number
E
Common communication
H
Provides power to sub station
Special
Order
Products
PC-359B
IF-DA-NLD
1
2
1
2
2
3
4
Blk
5
Blk
6
WHT
7
Wire
7
7
7
8
9
PC-359B (Solder side view)
Solder pads:
Numbered by
location on
board.
1
2
2
3
To 1
4
5 6
To 2
To Blk
To Blk
9
8
7
7
7
7
Pg. 1

Advertisement

loading

Summary of Contents for Aiphone NEM-20

  • Page 1 24V DC, 2A Power Supply (for 30 and 40 station masters) SUB STATION MOUNTING: IE-JA-NLD: 2-gang electrical box IF-DA-NLD: Surface mounts to 1-gang box NEM-LD NEM-n-LD Master Station - INSTRUCTIONS - NEM-20-LD PS-2410A PS-24E NEM-LD TERMINAL DEFINITIONS: Positive 24V DC Negative 1~40...
  • Page 2 2 common plus 1 individual per sub, looped; or 3 conductors homerun to each sub. Shielded cable is recommended. Use Aiphone #822203 for homerun wiring, #822206 for 4 stations on each run, or #822210 for up to 8 stations on each run.

This manual is also suitable for:

Nem-20-ldNem-10-ldNem-30-ldNem-40-ld