Instructions for Use Dear EasyTouch® BluLink® Blood Glucose Monitoring System Owner, Thank you for choosing EasyTouch® BluLink® Blood Glucose Monitoring System. This manual contains everything you need to know about your new glucose meter and how it works. Please take a moment to read the instructions carefully. We understand that self-testing of blood glucose level provides a way to control your diabetes and may give you peace of mind by testing regularly.
Page 3
capillary whole blood samples may be drawn from the fingertips, ventral palm, dorsal hand, upper arm, forearm, calf and thigh. The EasyTouch® BluLink® Glucose Control Solutions are for use with the EasyTouch® BluLink® Meter and EasyTouch® BluLink® Test Strips to check that the meter and test strips are working together properly and the test is performing correctly.
Page 4
WARNING: 1. The EasyTouch® BluLink® meter and the reusable lancing device are for single patient use only. Do not share them with anyone including other family members. Do not use on multiple patients. 2. All parts of the kit are considered bio-hazardous and can potentially transmit infectious diseases, even after you have performed cleaning and disinfection.
Page 5
8. Avoid getting hand lotions, oil, dirt or debris in and/or on the lancets, reusable lancing device and test strips. 9. Do not use EasyTouch® BluLink® meter in a dry environment. 10. Practice using the lancing device and become accustomed with its use. 11.
About your New EasyTouch® BluLink® Blood Glucose Monitoring System EasyTouch® BluLink® kit contents The following items are included: 1. EasyTouch® BluLink® Meter 6. Carrying Case 2. Twist Lancets (10) 7. One 3V Coin Battery, CR2032 3. Reusable Lancing Device 8. Log Book 4.
• Consult instructions for use manufacturer • Keep out of direct sunlight Serial Number Made in Korea. Distributed by: MHC Medical Products, LLC. 8695 Seward Road, Fair eld, OH 45011 Toll Free#: 877.358.4342 (Mon-Fri, 9am–5pm, EST) Item #: 849001 AD-082520.1...
EasyTouch® BluLink® meter display Low Battery Warning Symbol Alarm Symbol Troubleshooting Symbol Average Test Result System After Having a Meal Before Having a Meal After Taking Medication After Sport Activity Control Solution Symbol Blood Drop Symbol for Test Test Strip Code Symbol Test Result Unit Symbol Temperature / Date Time / Test Result Amount...
Before Your Test Make sure to read this section and the test strip package insert found in the test strip box carefully. You will need to have all of the necessary items to begin testing: Necessary Items: 3. Lancing device 1.
Comparing your meter and laboratory results Test results with the EasyTouch® BluLink® Blood Glucose Monitoring System are plasma-equivalent. This method will help you and your Healthcare Professional compare your meter results with laboratory test results. The EasyTouch® BluLink® test results and laboratory test results both are expressed in plasma-equivalent units.
Setting Up Your Meter The EasyTouch® BluLink® meter has a wide variety of functions. In the setup mode you have the ability to turn activity/meal flags on or off, set the date/time, designate the number of days for your glucose average calculation and set up to five daily alarms.
Page 13
Date / Time Test Unit Number of days for average After pressing and After pressing and releasing either releasing either the or After pressing and the or buttons to buttons to set the test releasing either the set the date and time, unit, confirm by ...
Page 14
NOTE 1. Year The year can range from 2015 to 2099. 2. Number of days for average This will set the number of days that you would like to get your average blood glucose calculation. The number of days can range from 1 to 99 days. To increase or decrease the number of days, press the arrows.
Auto-coding Function 1. EasyTouch® BluLink® meter has an automatic code recognition function. 2. The EasyTouch® BluLink® meter recognizes the code number automatically (e.g. 125). This is a very convenient function preventing the inconvenience of setting the code number on the meter every time. CAUTION 1.
Performing a Control Solution Test The EasyTouch® BluLink® Glucose control solutions contain a known amount of glucose that reacts with the EasyTouch® BluLink® test strip. By comparing your control solution test results with the expected range printed on the test strip vial, you can verify that the meter and test strips are working properly, and you are performing the test correctly.
Page 17
Check the expiration date before performing a control solution test. Do not use if expired. Please write down the expiration date on the control solution bottle after first opening. Gently shake the control solution before use. Discard the 1st drop of control solution, this will eliminate any residue.
Page 18
For example only: If you are using the Low (Level 1) control solution, according to this particular vial of test strips, your meter should show a number between 35 and 65. If you are using the High (Level 3) control solution, according to this particular vial of test strips, your meter should show a number between 225 and 345.
Page 19
If your control solution test falls out of range, please follow the next steps before contacting customer support: · Check the expiration dates on all the products you are using. Be sure you are using EasyTouch® BluLink® Glucose control solution. ·...
Performing Your Test Performing a blood test with your fingertip Step 1 Firmly insert the test strip into the meter test port. Insert down firmly in the direction of the arrow on the test strip (arrow down). Please do not insert the test strip upside down.
Page 21
CAUTION • If the code is not displayed within a short amount of time, pull the test strip out of the port and re-start the procedure from the beginning. • If the code on the LCD display window and the one on the test strip vial do not match, try another new test strip.
Page 22
NOTE: The lancing device included with your kit may differ from the one shown in this manual. If so, please refer to the instructions included with your device. Unscrew the lancing device cap. Insert a sterile lancet into the lancing device. Twist the protective cover off.
Page 23
Step 3 EasyTouch® BluLink® meter only requires 0.5 uL sample volume. • Place the edge of the test strip to the drop of blood. • The blood will be automatically ‘drawn’ into the test strip channel. • When your blood sample size is enough, your meter will automatically count down.
Page 24
Step 4 • After the beeping sound, the test will start automatically and your test result will appear in 5 seconds. It will begin counting down from 5 to 1 second on the LCD display window. When finished, the LCD window will display the result of your blood glucose level, temperature and time.
Disposing of Your Test Strips and Lancets Disposing of your test strip Once the test is complete, push the ejector button forward to remove the test strip from the meter. Used test strips may be considered bio hazardous waste in your area.
Reviewing Your Results: Reviewing your blood sugar The EasyTouch® BluLink® meter stores up to 500 test results in its built-in memory, along with the average sugar level for the number of days, which you have preset the glucose test meter to calculate. The latest The Second latest The Third latest...
Average Test Result Test Unit The Number of Tests Average Test Result Days Alternate Site Test Performing a blood test with an alternate site Upper Arm Forearm Ventral Palm Dorsal Hand Thigh Fingertips Calf The EasyTouch® BluLink® Blood Glucose Monitoring System gives you the ability to obtain a blood sample for testing your sugar from different areas of your body.
Page 28
Lancing and sampling from an alternate site area. Sampling from your upperarm, forearm, dorsal hand, ventral palm, thigh, or calf allows you to use your fingertips less often. You may find that obtaining a blood sample from an alternate site is less painful than using a fingertip.
Page 29
IMPORTANT We recommend that you test on your fingertips if you are testing for hypoglycemia (low blood glucose) or if you are suffering from hypoglycemia unawareness. To ensure accurate results when lancing your arm (forearm or upper arm), leg (calf or thigh), or palm (ventral palm or dorsal hand), clean the test site with soap and water.
The clear lancing device cap is used for alternate site testing Remove the lancing cap by twisting off. Insert a lancet and replace with the clear cap. To bring fresh blood to the surface of the test site, rub the test site vigorously for a few seconds until you feel it getting warm.
Page 31
NOTE The AST (Alternate Site Testing) tip is not included with the EasyTouch® BluLink® Glucose Monitoring System but can be purchased separately. For purchasing information, please call customer support toll free: 877-358-4342. (Mon-Fri, 9am-5pm, EST) REMEMBER • Consult with your Healthcare Professional before using alternate site testing.
Caring for your EasyTouch® BluLink® Blood Glucose Monitoring System Cleaning and disinfecting your EasyTouch® BluLink® Blood Glucose Monitoring System Why should cleaning and disinfecting the meter and the reusable lancing device be performed? Blood glucose meters and reusable lancing devices are at the high risk of becoming contaminated with bloodborne pathogens such as Hepatitis B Virus (HBV).
Page 33
• If you have any questions regarding proper cleaning and disinfecting procedures and purchasing the materials needed, Please contact your authorized representative or MHC Medical Products LLC. customer support: 877-358-4342 (toll free), Mon-Fri, 9am-5pm, EST Cleaning and disinfecting procedures 1. Wash your hands before performing cleaning and disinfecting procedures.
Page 34
CAUTION Take extreme care that the liquid does not soak into the data ports. Do not use any type of spray. • Dispose of the used wipes. • Wash your hands thoroughly with soap and water. The meter must be cleaned and disinfected a minimum of once per week.
Page 35
We recommend that you perform the cleaning and disinfecting procedures on it once per week. Your EasyTouch® BluLink® Blood Glucose Monitoring System has an expected life of 3 years and should withstand the cleaning and the disinfecting recommended in this Instructions for Use. We tested the meter and the lancing device with CaviWipes™...
Storage of your EasyTouch® BluLink® Blood Glucose Monitoring System To avoid the meter and test strips getting dirt, dust or other contaminants, please wash and dry your hands thoroughly before use. Meter Storage • Storage condition: 36~86˚F or 2~30˚C (Temperature). •...
USB / PC Connection You can transfer your test results from the EasyTouch® BluLink® meter to a computer. You will need to download the software from the following web site: (http://mhcmed.com/products/easytouch-diabetic-products/blulink-glucose- monitoring-system/) and purchase the computer cable from our sales representative.
Bluetooth Setup (BluLink® App) The EasyTouch® BluLink® meter stores glucose test result data and can transfer it to wireless devices such as Smart Phones (android and iOS) via Bluetooth wireless technology. Step 1 Ensure you have completed one or more tests on your EasyTouch® BluLink® meter and that your mobile device’s Bluetooth is active.
Page 39
Step 5 Select 'confirm' on the notification to connect the BluLink app and your mobile device. A flashing 'c' for confirmed will now appear on your meter to show that the pairing or connection between your meter and your mobile device has been successful.
Battery Installation To begin, place the meter on a flat surface and take the battery cover off of the back of the meter. The battery is to be inserted into the meter with the Positive (+) side of the battery facing upward, away from the prongs. Replace the battery cover.
Troubleshooting The following chart may help you identify certain problems, but may not solve all the problems that can occur. Contact your authorized representative customer support if the problem persists. Message What it means Action required Hardware is defective. Reboot the meter by removing and then replace the battery while no test strip is inserted.
Page 42
Message What it means Action required Blood sample is placed Wait for the meter to display the on the test strip before blinking blood icon before applying the symbol for blood your blood sample. blinks. 1. Color area of the test 1.
Page 43
Message What it means Action required The test result is over If “HI” appears on the LCD screen 600mg/dL for the Glucose result,the measured concentration is above 600mg/ dL. The test should be repeated to ensure that the test procedure was done correctly.
Inconsistent or Unexpected Test Results If you continue to get unexpected test results, check your system with control solution. If you experience symptoms that are not consistent with your glucose results, review and follow all instructions in this Instructions for Use. Never ignore symptoms or make significant changes to your diabetes control program.
Limitations of Warranty This warranty is subject to the following exceptions and limitations. 1. MHC Medical Products LLC. shall not be required to replace any units which are damaged or malfunction due to abuse, accidents, alteration, neglect, misuse, maintenance by someone other than MHC Medical Products LLC., or failure to operate in accordance with the instructions.
Need help?
Do you have a question about the EasyTouch BluLink and is the answer not in the manual?
Questions and answers
How to Reset my Members Mark BluLink Glucose Meter to factory reset
I need to reset all infomation back to zero please.