GRAND EFFECTS LIAUT24xxIM Operation And Maintenance Manual

Linear burner inserts automated operation

Advertisement

Quick Links

WARNING
FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment
by the jurisdiction in which the product will be installed where such state or local requirements exists. In the event no such state or
local requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation
and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all
warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property
damage, personal injury, or death. Improper installation and/or operation can create carbon monoxide gas and flue gases which can
cause serious injury, property damage, or death. For installations in the vicinity of occupied/living spaces, as an additional measure
of safety, Zodiac Pool Systems LLC strongly recommends installation of suitable carbon monoxide detectors in the vicinity of this
appliance and in any adjacent occupied spaces. Improper installation and/or operation may void the warranty.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Immediately switch off main gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
MAINTENANCE MANUAL
Grand Effects
Linear Burner Inserts
Automated Operation
IF THESE INSTRUCTIONS ARE NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT,
CAUSING PROPERTY DAMAGE, PERSONAL
INJURY, OR DEATH.
OPERATION AND
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LIAUT24xxIM and is the answer not in the manual?

Questions and answers

Summary of Contents for GRAND EFFECTS LIAUT24xxIM

  • Page 1 OPERATION AND MAINTENANCE MANUAL Grand Effects ® Linear Burner Inserts Automated Operation IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT, WARNING CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH. FOR YOUR SAFETY: This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists.
  • Page 2: Table Of Contents

    Section 1. Important Safety Instructions ..3 Section 2. General Description ...... 4 Product Overview ............4 Product Contents............5 Section 3. Installing the Grand Effects ® Linear Burners ......6 Preparing the Linear Burner for Installation....6 Gas and Electric Requirements........7 Construction of Burner Cavity ........8...
  • Page 3: Section 1. Important Safety Instructions

    Visit www.zodiacpoolsystems.com for additional free copies of these instructions or call Zodiac Technical Support at 800.822.7933 (U.S.) or Grand Effects at 949.697.5270 ATTENTION INSTALLER This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment.
  • Page 4: Section 2. General Description

    This manual provides instructions for installing and replacing the Grand Effects Linear Burner Assembly. ® • There are two possible mounting locations for the Grand Effects Sub Panel: Inner and Outer Mount. • Outer Mount means the Sub Panel will be located outside of the burner cavity.
  • Page 5: Product Contents

    Qty 1 ® 3. Sub-Panel Qty 1 4. Propane Adder (required with propane) Qty 1 5. Pre-assembled Pipe Train (optional) Qty 1 6. Key Valve (optional) Qty 1 7. Grand Effects Linear Burner Automated Operation Qty 1 and Maintenance Manual...
  • Page 6: Section 3. Installing The Grand Effects Linear Burners

    Page 6 Linear Burner Inserts Automated Operation Section 3. Installing the Grand Effects ® Linear Burners WARNING Risk of Electrical Shock or Electrocution. This linear burner must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code (Canadian ®...
  • Page 7 Linear Burner Inserts Automated Operation Page 7 BONDING THE LINEAR BURNER Loosen the hose clamp at one side of the spillway and disconnect the hose. Remove brass barb fitting and set aside. Use two (2) 1/2” sealing rings on the gas piping for bonding. Securely thread the first sealing ring to the bottom of the pipe threads, then wrap with bonding wire and thread on the remaining sealing ring.
  • Page 8: Gas And Electric Requirements

    Page 8 Linear Burner Inserts Automated Operation Gas and Electric Requirements 120 VAC / 60 Hz to Grand Effects Control ® Input Voltage Panel 24Vac or 12Vac (each unit requires less than Output Voltage 3 amperes) Gas Type Natural Propane Gas Pressure (Nominal) 7”...
  • Page 9: Construction Of Burner Cavity

    Linear Burner Inserts Automated Operation Page 9 Construction of Burner Cavity Burner Cavity Depth- 20” Minimum Cavity Depth Requirement for Subpanel Inner Mount 12” Minimum Cavity Depth Requirement for Subpanel Outer Mount Required # of Support Burner Inner Optimum Burner Vent Openings Plate Length...
  • Page 10: Installing The Linear Burner

    120v source, including auxiliary relay from the pool controller or home system. Typically, the pool controller is the device that turns the unit on and off. If a pool controller is not available, Grand Effects can provide a hand held remote system or an electrician can wire a decorative switch...
  • Page 11 VALVE GAS INLET (PROPANE) 12VAC 120 VAC 60HZ INPUT OUTLET TO CONTROL PANEL PROPANE ADDER SUPPLIED BY GRAND EFFECTS ® 12 VAC IN CONDUIT (UNDERGROUND) 3/4” - 1” GAS PIPING (UNDERGROUND) Figure 2. Propane Gas CONTROL PANEL (TYPICALLY MOUNTED WITH...
  • Page 12 Figures 4 and Figure 5. NOTE: DRAINAGE REQUIRED FOR NATURAL GAS ONLY. DRAINAGE DRAINAGE MULTIPLE VENTS REQUIRED CONSULT GRAND EFFECTS MANUAL FOR NUMBER AND SIZE GAS AND ELECTRICAL CONDUIT TO BURNER Figure 4. Inner Mount Venting - Side View VENTS...
  • Page 13 12. Inner Mount Subpanel should be mounted on vertical end wall that is closest to pilot. This will allow access for service. 13. Connect inlet and outlet gas hoses supplied by Grand Effects ® making sure all connections are tight. Keep hoses and wires away from underside of Support Plate.
  • Page 14: Installing The Sub-Panel

    Outer Mount Sub Panel must be installed within 4 ft of Pilot Assembly located at end of Burner Assembly. Grand Effects pilot gas hose and electrical wires from Subpanel to pilot is 5 ft maximum.
  • Page 15 Linear Burner Inserts Automated Operation Page 15 Pilot Spark Wire Pilot Ground Wire Pilot Flex Gas Hose Control Relay or Grand Effects Switch by others Control Panel Grand Effects Sub Panel 120 VAC Grand Effects Line Burner 12 VAC Gas Supply Source Flex Gas Hose by Grand Effects...
  • Page 16 Page 16 Linear Burner Inserts Automated Operation GRAND EFFECTS BURNER 1/2” - 1” L BRACKET MULTIPLE VENTS REQUIRED CONSULT GRAND EFFECTS MANUAL FOR NUMBER AND SIZE ELECTRICAL FROM LOCATE GAS AND GRAND EFFECTS ELECTRICAL AT CONTROL PANEL PILOT SIDE OF...
  • Page 17 Linear Burner Inserts Automated Operation Page 17 3.5.2 INSTALLATION OF SUB-PANEL (OUTER MOUNT) IMPORTANT! The Sub Panel must be located close to NOTE: Control Panel Grand Effects Control Relay or ® pilot end of burner to connect 5 feet of wire from Sub Panel can be installed up to Control Panel Switch by others...
  • Page 18 Page 18 Linear Burner Inserts Automated Operation LENGTH - SEE CHART GRAND EFFECTS ® GRAND EFFECTS LINEAR BURNER SUB PANEL 10.5” OUTER GAS AND MOUNT ELECTRICAL CONDUITS TO BURNER Figure 18. Burner Cavity - Outer Mount Top View GRAND EFFECTS BURNER 1/2”...
  • Page 19: Section 4. Burner Setup And Adjustment

    Linear Burner Inserts Automated Operation Page 19 Section 4. Burner Setup and Adjustment Burner Setup At the control panel, turn the manual gas valve to the “Off” position. With 120VAC coming into the Control Panel, turn the switch located in the panel to the “On”...
  • Page 20: Burner Adjustment

    To avoid the risk of property damage and serious injury, including death, when purging air from a propane system, be sure to disconnect wires going to the burner assemblies (terminals X1/X2) located in Grand Effects control panel. There should be no power at the burner ®...
  • Page 21: Section 5. Maintenance

    Important: Gas must be securely shut off when not in use. Note: If any problems are present, consult a licensed heating specialist or call Grand Effects ®...
  • Page 22: Section 6. Operation

    WARNING To avoid the risk of property damage and serious injury, including death, before you turn on the Grand Effects System, make sure that features are clear of people, animals, or any objects that are combustible. Operating Instructions To turn unit “On”:...
  • Page 23: Section 7. Troubleshooting

    Troubleshooting WARNING To avoid the risk of property damage and serious injury, including death, call Grand Effects or a licensed heating professional if you experience ® problems with this unit. All work on this unit must be performed by a licensed heating professional.
  • Page 24 Page 24 Linear Burner Inserts Automated Operation WARNING Model 100 Burner Assembly In order to avoid the risk of property damage, serious injury, including death, turn OFF power and gas at the control panel prior to initiating troubleshooting steps. Turn power and gas ON once troubleshooting is complete.
  • Page 25: Section 8. Wiring Diagram

    LB-1 LEGEND L = 120 VAC LINE TERMINAL STRIP IN N = 120 VAC NEUTRAL ® GRAND EFFECTS GND = EARTH GROUND CONTROL PANEL X1 = 12 VAC HOT X2 = 12 VAC COMMON ELECTRICAL SERVICE 120 VAC SINGLE PHASE...
  • Page 26 Page 26 Linear Burner Inserts Automated Operation NOTES...
  • Page 27 Linear Burner Inserts Automated Operation Page 27 NOTES...
  • Page 28 Grand Effects 23121 Arroyo Vista, Suite B, Rancho Santa Margarita, CA 92688 1.949.697.5270 | www.GrandEffects.com Zodiac Pool Systems LLC 2882 Whiptail Loop #100, Carlsbad, CA 92010 1.800.822.7933 | www.ZodiacPoolSystems.com ©2020 Zodiac Pool Systems LLC. All rights reserved. ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license.

Table of Contents