QT Thunder 24 - II Maintenance Instructions
The life expectancy of your QT Thunder
24 -II unit is 10 – 15 years, provided it is
serviced and maintained on a regular basis.
It is recommended that you perform a
simple cleaning and maintenance of your
unit every 6 months. Maintenance kits
are available through your distributor.
irremovable stains. The plate can be reused provided there are no breaks or stains.
Step 3.) Use the same alcohol wipe to wipe out the exposed areas inside the unit. Spread the generator frame
apart to wipe the inside of the metal plates that make contact with the generator plate. Be sure to also wipe
the base of the frame completely.
Step 4.) Once the ceramic plate is completely dry, reinsert the plate into the generator frame or replace the
existing plate.
Step 5.) Reattach the top cover to the unit and put screws back in place.
Step 6.) Remove and discard the green filter on the back of the machine and replace with new filter.
Step 7.) You may at this point have to change your 200mA fuse. To test your fuse, simply turn the unit on.
If the green ozone light comes on you have completed maintenance of the unit and are ready to put it back in
service. If the light does not come on, locate the 200mA fuse holder on the back of the unit and remove the
holder with a flat head screwdriver by turning the holder ¼ turn. Remove the blown fuse and replace the
fuse. Your unit should now be ready to go back to work.
If you are having problems with your ozone machine please refer to the following instructions:
ensure there is power to the outlet. Plug the unit in. Check the fuse marked 2 amp on the back of the
unit. Replace with spare if blown. If the unit still does not operate contact your distributor.
3.
There is no display on the face of the timer. The Lithium battery should operate your timer for 3 years
or more under typical conditions. High or low temperature or frequent use of the manual pushbutton
will reduce the battery life. Replace the battery when the digital display is dim or if the timer fails to
operate. The timer has built-in memory protection providing at least 15 seconds to change a week
battery without losing your settings.
4.
If for any reason you are not happy with the performance of this unit contact customer service.
Toll Free: 1-866-67 OZONE(69663) Tel: 1-315-393-5454 Fax: 1-315-393-5511
1.
The fan comes on, but the green light does not. Remove the top cabinet from the
unit and check the condition of the ceramic plate. Replace if broken. Replace top
cabinet. Remove and replace the .200 milliamp fuse in the back of the unit. If the
green indicator light is still out contact your distributor.
2.
When you turn the unit on nothing happens. First check your power source to
Queenaire Technologies, Inc.
Ogdensburg, NY 13669
Before you begin performing any work to your ozone
unit, be sure to unplug the electrical cord.
Step 1.) Remove two screws on the top of the unit as well
as the top two screws on each side of the unit. Remove
the top cover from the unit.
Step 2.) Carefully remove the white ceramic generator
plate from its frame. The plate should lift easily by pulling
from the top straight up and out of the frame. Use an
alcohol wipe to gently wipe the plate free of any dirt or
stains. Inspect the plate carefully for cracks, breaks or