Operating QT Thunder 24 - II
Following are basic instructions for programming your unit to eliminate odors in an area up
to 10,000 cubic feet when the treated area is unoccupied.
T
his unit features a programmable timer with up to 6 On/Off setting pairs (12 automatic switch
settings). Each setting time can be once a week, every day, every weekday, or only on weekends. The
timed settings combined with a fixed ozone output of 300 mg/hr, allows the user the ability to
effectively deodorize a given area up to 10,000 cu/ft on a scheduled basis when the area is vacant. A
manual override option gives you ozone on demand for a quick clean up.
Determine your Programmed Settings
The time needed to effectively eliminate odors in a given area depends greatly on the size of the room, the level
of odor in the room, temperature and humidity. Our recommendation is that you run the unit for 30 minutes
for every 2400 cu/ft of space being treated. You should adjust the unit for shorter run times if you detect an
ozone odor after the unit has been off for a time equal to the time it was in operation. If the odor is still present
after the unit has ran you should adjust the unit to run for longer periods. After the first week of treatment you
may have to adjust the unit to shorter run times as the odor factor should be significantly lower. In the summer
months, you may have to adjust the unit to run for longer intervals, as the humidity levels will decrease ozone
output. You should always allow ample time for ozone levels to dissipate before occupying a treated area.
Usually an amount of time equal to the time the unit was in operation is sufficient. If you need help in
determining your programmed settings, please contact Customer Service at 1-866-67 OZONE.
While smell is not an accurate guide to ozone levels, in levels above .03 ppm ozone has a very strong
unpleasant odor. If you are experiencing a strong odor, headache, dry nose and/or dry throat, you
should adjust the run time for shorter periods or allow a longer period of time before occupying the
area to allow the levels to dissipate.
How Does QT Thunder 24 - II Eliminate Odors?
All Queenaire Technologies, Inc. units eliminate odors by producing a controlled level of ozone. Ozone is
created naturally in our environment by lightning and the suns ultraviolet rays. It is best known for its benefit in
the stratosphere for protecting us from the suns rays. What you may not know is that it is also that fresh smell
you experience after a lightning storm. Ozone is Mother Nature's solution to outdoor odor problems. QT
Thunder-24 incorporates a technology that duplicates the effect of lightning and creates ozone indoors.
The end result is the same, a fresh, odor free environment !