SAFETY INSTRUCTIONS

• Ensure that there is sufficient space on all sides while working.
• Protect the device from direct sunlight.
WARNING
Advisory circular 20.68B defines minimum safe levels of RF energy radiation. The RF
energy radiated by the RDR-7000 weather radar system is low level.
• Operation in test mode does not emit harmful radiation.
• No tests should be made in the vicinity of fueling operations.
• Do not operate the radar in any other mode unless all personnel are at a safe distance.
SAFE DISTANCE
(for 10 miliwatts/centimeter )
Maximum Permissible Exposure
Level (MPEL) distance
Safe fuel distance
Test Mode distance
RDR-7000 with 18"
2
Antenna
10.1 ft
(3.1 m)
1.9 ft
(0.6 m)
0.67 in
(1.7 cm)
RDR-7000 with 12"
Antenna
7.0 ft
(2.1 m)
1.3 ft
(0.4 m)
0.46 in
(1.2 cm)