Bartscher A300.067 Instruction Manual
Bartscher A300.067 Instruction Manual

Bartscher A300.067 Instruction Manual

Electronic digital scale

Advertisement

Quick Links

Elektronische Digital-Waage
Bedienungsanleitung griffbereit
D/A/CH
am Produkt aufbewahren!
Electronic Digital Scale
*
Keep this instruction manual
GB/UK
ready to hand at the product!
Balance numérique électronique
Conserver le mode d'emploi à
F/B/CH
portée de main avec le produit!
A300.067 / A300.150
Seite 2 bis 14
from page 15 to 27
de page 28 à page 40
V5/0609
- 1 -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A300.067 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bartscher A300.067

  • Page 1 Elektronische Digital-Waage A300.067 / A300.150 Bedienungsanleitung griffbereit D/A/CH Seite 2 bis 14 am Produkt aufbewahren! Electronic Digital Scale from page 15 to 27 Keep this instruction manual GB/UK ready to hand at the product! Balance numérique électronique de page 28 à page 40 Conserver le mode d’emploi à...
  • Page 2 22-25 6. Cleaning and maintenance 6.1 Safety advice 25-26 6.2 Cleaning 6.3 Safety instructions for maintenance 7. Waste disposal 26-27 Bartscher GmbH Franz-Kleine-Str. 28 D-33154 Salzkotten phone: +49 (0) 5258 971-0 Germany fax: +49 (0) 5258 971-120 - 15 -...
  • Page 3: Key To Symbols

    1. General information 1.1 Information about the instruction manual This instruction manual contains information about the installation, operation and maintenance of the device and should be consulted as an important source of information and reference guide. Awareness of the safety instructions and instructions for use in this manual will ensure the safe and correct use of the device.
  • Page 4: Copyright Protection

    The instruction manual was translated with all due care and attention. However, we do not accept liability for any translation errors. The German version of this instruction manual is definitive. If the delivery consists of a special model, the actual scope of delivery may differ from the descriptions and illustrations in this manual.
  • Page 5: General Information

    2.1 General Information This device is designed in accordance with the presently applicable technological standards. However, the device can pose a danger if handled improperly and inappropriately. Knowing the contents of the instruction manual as well as avoiding mistakes and thus operating this device safely and in a fault-free manner is very essential to protect yourselves from the hazards.
  • Page 6 Electronic digital scale is only intended for weighing objects of a weight up to 60 (150) kg. CAUTION! Do not use the device for anything beyond or other than its intended use. The manufacturer and/or authorized parties do not accept any claims resulting from damage caused by using the device not according to its intended use.
  • Page 7: Module Overview

    In case of longer storage (> 3 months) make sure you check the state of the packaging and the parts regularly. If required refresh or renew. 4. Technical data 4.1 Technical specification Name Electronic Digital Scale A300.067 A300.150 Item no.: Weighing range: up to 60 kg up to 150 kg...
  • Page 8: Operating Panel

    Operating Panel ON/OFF HOLD Measuring value stays on the display for 120 seconds UNIT kg/lb Conversion ZERO for TARE Sets the display to zero or deducts the weight of the container Display Weighing unit (kg / lb) Negative value indicator Stable indicator Indicates when the A/D value reading is stable...
  • Page 9: Safety Instructions

    Device Connection for AC adaptor (power pack) 5. Installation and operation 5.1 Safety instructions WARNING! Hazard via electrical current! The device can cause injuries due to improper installation! Before installation the local power grid specification should be compared with that of the device (see type label). Connect the device only in case of compliance! Take note of the security advice! •...
  • Page 10: Installation

    5.2 Installation • Unpack the device and dispose of all packaging material. • Place the electronic digital scale on a level and safe surface. • Avoid exposing the scale to direct sunlight, as this may lead to discoloration or malfunctions. •...
  • Page 11 Press to turn the power off. Press first, then press , while keeping pressed, the display will shows A_ON or A_OFF. • Selection of auto shut off mode: When the balance enter function setting menu. Press key, the display will show A_ON or A_OFF.
  • Page 12: Calibrating The Scale

    Place the objects to be weighed in the container. The "stable" indicator appears when the value becomes stable. Calibration This scale is equipped with an automatic calibration function. Therefore, you actually never have to calibrate the scale. If you think that the scale displays incorrect values, you can use the manual calibration function to check whether the scale is inaccurate and resolve this error.
  • Page 13: Safety Instructions For Maintenance

    To protect yourself from electric shock, never immerse the device, its cables and the plug in water or other liquids. ATTENTION! The device is not designed to be directly sprayed off with a water jet. Hence, you must not use pressure water jets for the cleaning of the device! 6.2 Cleaning The device should be cleaned regularly.
  • Page 14 NOTE! For the disposal of the device please consider and act according to the national and local rules and regulations. Bartscher GmbH Franz-Kleine-Str. 28 D-33154 Salzkotten phone: +49 (0) 5258 971-0 Germany fax: +49 (0) 5258 971-120 - 27 -...

This manual is also suitable for:

A300.150

Table of Contents