La Gard Basic Series Manager Instructions

Dual-handed swing bolt lock or dead bolt

Advertisement

Quick Links

LOCKS
Dual-handed
Dead Bolt
Swing Bolt
FEATURES
MANAGER COMBINATION
(Factory set to 1-2-3-4-5-6)
• Add/Remove User
• Enable/Disable User
USER COMBINATION
• Open Lock
• Change Combination
WRONG TRY PENALTY
• Four (4) consecutive invalid
combinations initiates five (5) minute
delay period.
LOW BATTERY WARNING
• Repeated LED flashing and beeping
after opening indicates battery is low
and needs immediate replacement.
• When battery level becomes too low
to safely operate the lock, any key
press will give a low battery warning,
and the battery must be changed
before the lock will operate.
AUDIO AND VISUAL SIGNAL
• Double signal - two (2) LED flashes
and two (2) beeps - indicates entry is
valid or accepted.
• Triple signal - three (3) LED flashes
and three (3) beeps - indicates invalid
or not accepted.
OPENING THE LOCK
1. Enter valid six (6) digit combination.
The lock will signal a valid combination
entry with a double signal.
2. Within four (4) seconds, turn the
keypad to the open position (clock-
wise) if using a dead bolt style lock, or
turn the handle to the open position if
(P/N) 760.128 Rev C EN 02/10 • © copyright 2004-2010
Dual-Handed Swing Bolt Lock or Dead Bolt
MANAGER INSTRUCTIONS
3000* Entry
3710* Entry
(* for Swing Bolt only)
BASIC SERIES
3802 Firmware
ENTRY DEVICE OPTIONS
3715* Entry
using a swing bolt style lock.
3. Pull door open.
4. Close the door, and check the locked
status of the container with the handle
of the boltworks.
• Invalid Combination Entry - Lock will
signal three (3) times.
• Security Considerations - On safes
using more than one lock the
swing bolt must lock first.
CHANGING MANAGER AND USER
COMBINATIONS
ALWAYS PERFORM THIS OPERATION
WITH THE DOOR OPEN
1. Enter "zero" six times.
2. Enter your existing six (6) digit
combination one time.
3. Enter your new six (6) digit
combination two times.
4. If a mistake is made wait thirty (30)
seconds and repeat steps 1 - 3.
5. Test lock operation several times
before closing the door.
• Valid Combination - Double signal
after valid six (6) digit combination
is entered.
• Invalid Combination - Triple signal
indicates the old combination is
still valid.
CAUTION: When selecting a
combination do not use birthday or
other predictable data that could give
correlation between the user and
combination. Keep the combination
secret.
3035
3750
Entry
Entry
Kaba Mas LLC
3190 Privat
II
(Optional)
Page 1 of 2

Advertisement

loading

Summary of Contents for La Gard Basic Series

  • Page 1 BASIC SERIES 3802 Firmware Dual-Handed Swing Bolt Lock or Dead Bolt MANAGER INSTRUCTIONS LOCKS ENTRY DEVICE OPTIONS 3035 3750 3190 Privat 3000* Entry 3710* Entry 3715* Entry Dual-handed Dead Bolt Entry Entry (Optional) (* for Swing Bolt only) Swing Bolt FEATURES using a swing bolt style lock.
  • Page 2 ADD USER (MANAGER ONLY) ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN 1. Enter the Manager combination and hold down last digit of combination until the lock signals with two sets of double beeps. 2. Press 1. Lock signals twice. 3.

This manual is also suitable for: