• Integrated inlet solenoid valve to prevent oil cross contamination when the battery is dead. • Equipped with one 18VDC 6.0aH battery (CPS p/n VPCXB18) Optional battery charger availible (CPS p/n VPCXBC). Compatible with BL18 series batteries and battery chargers.
GENERAL INFORMATION General Safety Instructions ONLY QUALIFIED SERVICE PERSONNEL SHOULD OPERATE THIS UNIT. SOME COUN- TRIES MAY REQUIRE THE USER TO BE LICENSED. PLEASE CHECK WITH YOUR LOCAL GOVERNMENT AGENCY. DANGER - Avoid breathing refrigerant CAUTION - Avoid breathing refrigerant vapors vapors and lubricant vapor or mist.
GENERAL INFORMATION Specifications Model Number VPC2S-18VDC VPC2D-18VDC Stages Motor Size (HP) RPM 3000 Dimensions (Inches) 10.5 x 4.5 x 8 12.5 x 4.5 x 8 7.5 lbs w/o battery, 8.2 lbs w/o battery, Weight (lbs) 9 lbs w/ battery 9.7 lbs w/ battery Operating Temperature 0˚C (32˚F) to 52˚C (125˚F) Range...
OPERATION VPC Single Stage Series Parts Initial Preparation 1. Fully charge the 18VDC Li-on battery. 2. The vacuum pump is shipped without oil in the reservoir. Remove the exhaust / oil fill cap and add oil until it is seen in the middle of the oil sight glass. Re-secure cap. 3.
It is recommended to change the vacuum pump oil after 25 hours of usage. The purity of the oil will determine the final vacuum level achieved. Always use the CPS recommended vacuum pump oil (VPOQ / VPOP / VPOG). The oil provided with the pump has been specially blended to maintain maximum visosity at normal running temperatures as well as cold weather starts.