Replacement filter unit

Advertisement

Replacing the air filter unit (continued)
5) Attach the unused main filter unit to the projector.
Perform Step 3) in the reverse order.
z
Push in the main filter unit securely until it clicks into place.
z
6) Attach the unused pre-filter to the air filter cover.
There is no specification of the front and back for attaching the pre-filter.
z
Put the pre-filter into the claws (3 places) on one side of the air filter cover (Fig. 4),
z
and then push each portion slowly in the direction of the arrows into the claws
(3 places) on the other side (Fig. 5). Please make sure that there is no damage or
deformation at the contact areas of the pre-filter with the claws when attaching it.
Claws
7) Attach the air filter cover to the projector.
Perform Step 2) in the reverse order to close the air filter cover, and push in the air
z
filter cover securely until it clicks into place.
8) Connect the power plug, set the <MAIN POWER> switch to <ON>, and press the
power button < v / b > on the control panel or on the remote control to turn on the
power and start the projection.
9) Press the <MENU> button to display the main menu, then press as to select
[PROJECTOR SETUP].
10) Press the <ENTER> button.
11) Press as to select [FILTER COUNTER].
12) Press the <ENTER> button.
The [FILTER COUNTER] screen is displayed.
z
13) Press as to select [FILTER COUNTER RESET].
14) Press the <ENTER> button.
The [FILTER COUNTER RESET] screen is displayed.
z
15) Press qw to select [OK], then press the <ENTER> button.
The filter usage time is reset.