Download Print this page

Wolf WF-300 Operation And Maintenance Instructions page 2

Led floodlite

Advertisement

When
terminals
certificates IECEx SIR 05.0035U and IECEx
SIR 05.0037U are used, they shall only be
installed and wired with cable within a
temperature range of -10°C to 80°C.
When cross-connecting combs are used on
terminals to certificates IECEx SIR 05.0035U
and IECEx SIR 05.0037U, the relevant
conditions of certification associated with
those certificates shall be applied.
Cable entry holes shall be fitted with either an
appropriately
certified
appropriately
certified
These shall provide and maintain a minimum
enclosure ingress protection of IP66 or IP67
as appropriate.
The
LED
assembly
following the failure of a maximum of 8
individual LED's.
Internal fuse replacement must be the correct
fuse value and be capable of withstanding a
short circuit current of 1500A.
User must ensure that when used, the
protective film must remain fixed in place at all
times when the equipment is being moved.
If the Floodlite head is not situated within the
protective frame/stand ensure the unit is de-
energised before moving.
MAINTENANCE
1. Isolate the Floodlite from the mains supply
and allow to cool before carrying out any
maintenance work.
2. It is essential that all Floodlites are maintained
in accordance with the requirements of
EN60079-17.
3. The cable should be inspected before each
use. Regular close inspections must be
carried out to ensure the cable is not
damaged in any way. Particular attention
should be paid to gland and socket entries.
4. IMPORTANT. No modifications are permitted
to the Floodlites, all spare parts must be
purchased
from
unauthorized modifications or spare parts will
invalidate certification.
ELECTRICAL DATA
Total circuit watts 60W, power factor correction
better the 0.95. Voltage range 100V to
254V +/-10% 50/60Hz or 24V +/-10% AC/DC –
see rating label.
in
accordance
with
cable
gland
blanking
element.
must
be
replaced
the
manufacturer,
CHANGING LED ASSEMBLIES
Isolate the Floodlite, remove the lid assembly by
releasing the 4 socket head bolts that are
retained in the polycarbonate cover,
LED assembly can now be removed by releasing
the 4 socket head screws, the casting with the
encapsulated LED's can now be discarded.
Fitting a new LED assembly is a reversal of the
above procedure.
DISPOSAL OF WASTE MATERIAL
or
Disposal of packaging, Floodlite and old LED
assemblies should be carried out in accordance
with national regulations.
IECEx Scheme Certification
IECEx Scheme Certificate Number:
IECEx BAS 10.0016
Ex emb IIC T4 Gb (Ta= -20
o
Ex t IIIC T103
IEC Standards applied:
IEC60079-0:2007, IEC60079-18:2009, IEC60079-
7:2006/07, EN61241-1:2004
WARNING: USE ONLY GENUINE WOLF
REPLACEMENT PARTS.
The Wolf Safety Lamp Co. Ltd has a policy of
continuous product improvement. Changes
in design details may be made without prior
notice.
SPARE PARTS
Description
Protective Lens Film 3 pack
Stand and Bridle
Stainless Bolt Pivot Kit
4 off Stainless Bolt and 'O' Ring kit
Polycarbonate Lens Cover with Seal
LED Panel
Trumpet Gland
EX Terminal block
Internal Fuse Low Voltage (24V)
Internal Fuse High Voltage (110-230V)
Wolf Safety Lamp Company
o
o
C to +50
C)
C Db IP66 & IP67
Wolf Part Number
WWW.CABLEJOINTS.CO.UK
THORNE & DERRICK UK
TEL 0044 191 490 1547 FAX 0044 477 5371
TEL 0044 117 977 4647 FAX 0044 977 5582
WWW.THORNEANDDERRICK.CO.UK
the inner
WF-650/3
WF-698K
WF-641
WF-645
WF-647
WF-649
LL-311
WF-653
WF-262
WF-264

Advertisement

loading