ARTHUR HOLM DynamicCourtesyBox AHCBB User Manual page 13

Motorised courtesy boxes for furniture integration
Table of Contents

Advertisement

AHnet PROTOCOL
Commands
COMMAND
DESCRIPTION
OPEN THE UNIT
FA XX 01 01 00
CLOSE THE UNIT
FA XX 01 00 00
BUTTON LOCK
FA XX 04 01 00
BUTTON UNLOCK
FA XX 04 00 00
FA XX 14 00 00
INQUIRY CONTROL BYTE
XX
Number of the device address. Up to 30 devices for each
RS422 BUS
CB1
Response in 8 bits of the device status
CB2
Response in 8 bits of the device status
CB1
BITE
CLOSED
OPENED
PROTECTION STOP
UNIT OK
CB2
BITE
BUTTON LOCK
BUTTON UNLOCK
To send an order to all the devices, you must use the address:
F5 Hex. (Byte1)
In this case, the units do not send a reply.
7
6
5
4
1
1
0
1
7
6
5
4
RESPONSE
FB XX 01 01 00
FB XX 01 00 00
FB XX 04 01 00
FB XX 04 00 00
FB XX 14 CB1 CB2
3
2
1
0
0
1
0
1
1
0
3
2
1
0
1
0
13