Installation instruction Control Panel for Fire Ventilation SVM EI 24V-5A / SVM EI 24V-8A Fire ventilation Comfort ventilation 24VDC max. 5A/8A 1 fire ventilation group, 1 comfort group Connection for manual control points, wind- and rain sensor, comfort switches, smoke detectors and Fireman’s Priority Switch.
Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Address of installation Table of contents Address of installation / Description of installation ................2...
Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Safety rules during installation and operation General description The control panel can be used for electrical opening of e.g. skylights, smoke hatches or similar in The control panel may only be installed and maintained by personnel authorized for installation of automatic electrical fire ventilation equipment.
Red 2,5mm2 Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A RESET Connection to motor- (actuator-) output and line monitoring Black 2,5mm2...
Max. 8A DIP settings see page 13 START termi Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A FUSE F1 - fast...
Page 6
Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A REMOTE no: 111894 Connection SVM EI 24V - 5A/8A ALARM BUZZER LED 1 Actuator open (red). Lit when actuator is opening.
Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A LEDs on main board and front panel Complete jumper settings for SVM EI PCB...
Puls Max. 8A START termination ® Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A FUSE F1 - fast ® BUS Master...
LED 4 Line failure actuator (red). Lit for line failure on actuator. Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A LED 5 Line failure fire switch (red).
Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Lock-Out Mode SLAVE Lock-Out Mode MASTER Only mandatory Only mandatory Slaves are connected to Smoke Vents on each floor.
Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Part nos. and accessories (DK) YDEEVNEDEKLARATION IHT. FORORDNING NR. (EU) 305/2011) (UK) DECLARATION OF PERFORMANCE ACCORDING TO REGULATION NO. (EU) 305/2011)
Page 12
Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Service / Maintenance Record System Date Company Engineer Next Due Comments...
Control for Fire and Comfort Ventilation Type SVM EI 24V-5A / SVM EI 24V-8A Technical specifications SVM EI 24V-5A SVM EI 24V-8A Power supply 230VAC / max. 1.2A 230VAC / max. 1.7A Output supply 24-28VDC 24-28VDC Motor outputs 1 pcs. (line detecton: 1-4 lines) 1 pcs.