Loren Cook IMH Installation, Operation And Maintenance Manual

Industrial material handler

Advertisement

Quick Links

®
This publication contains the installation, operation and
maintenance instructions for standard units of the IMH-
Industrial Material Handler.
Carefully read this publication and any
supplemental documents prior to any
installation or maintenance procedure.
Loren Cook catalog, IMH, provides additional informa-
tion describing the equipment, fan performance, available
accessories and specification data.
For additional safety information, refer to AMCA Publi-
cation 410-96, Safety Practices for Users and Installers of
Industrial and Commercial Fans.
All of the publications listed above can be obtained from:
• lorencook.com
• info@lorencook.com
• 417-869-6474 ext. 166
For information on special equipment, contact Loren
Cook Company Customer Service Department at
417-869-6474.
Receiving and Inspection
Carefully inspect the fan and accessories for any dam-
age and any shortage of accessories immediately upon
receipt of the fan.
• Turn the wheel by hand to ensure it turns freely and does not
bind.
• Inspect dampers (if supplied) for free operation of all mov-
ing parts.
• Record on the Delivery Receipt any visible sign of damage.
IMH IO&M
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
IMH
Rotating Parts & Electrical Shock Hazard:
Fans should be installed and serviced by qualified person-
nel only.
Disconnect electric power before working on unit (prior to
removal of guards or entry into access doors).
Follow proper lockout/tagout procedures to ensure the unit
cannot be energized while being installed or serviced.
A disconnect switch should be placed near the fan in order
that the power can be swiftly cut off, in case of an emer-
gency and in order that maintenance personnel are pro-
vided complete control of the power source.
Grounding is required. All field-installed wiring must be
completed by qualified personnel. All field installed wiring
must comply with National Electric Code (NFPA 70) and all
applicable local codes.
Fans and blowers create pressure at the discharge and
vacuum at the inlet. This may cause objects to get pulled
into the unit and objects to be propelled rapidly from the
discharge. The discharge should always be directed in a
safe direction and inlets should not be left unguarded. Any
object pulled into the inlet will become a projectile capable
of causing serious injury or death.
When air is allowed to move through a non-powered fan,
the impeller can rotate, which is referred to as windmill-
ing. Windmilling will cause hazardous conditions due to
unexpected rotation of components. Impellers should be
blocked in position or air passages blocked to prevent draft
when working on fans.
Friction and power loss inside rotating components will
cause them to be a potential burn hazard. All components
should be approached with caution and/or allowed to cool
before contacting them for maintenance.
Under certain lighting conditions, rotating components
may appear stationary. Components should be verified to
be stationary in a safe manner, before they come into con-
tact with personnel, tools or clothing.
Failure to follow these instructions could result in death or
serious injury.
The attachment of roof mounted fans to the roof curb as
well as the attachment of roof curbs to the building struc-
ture must exceed the structural requirements based on the
environmental loading derived from the applicable build-
ing code for the site. The local code official may require
variations from the recognized code based on local data.
The licensed engineer of record will be responsible for pre-
scribing the correct attachment based on construction ma-
terials, code requirements and environmental effects spe-
cific to the installation.
1
IMH
Industrial Material Handler
B51221-002

Advertisement

Table of Contents
loading

Summary of Contents for Loren Cook IMH

  • Page 1 Industrial Material Handler ® INSTALLATION, OPERATION AND MAINTENANCE MANUAL This publication contains the installation, operation and maintenance instructions for standard units of the IMH- Industrial Material Handler. Rotating Parts & Electrical Shock Hazard: Carefully read this publication and any supplemental documents prior to any Fans should be installed and serviced by qualified person- installation or maintenance procedure.
  • Page 2: Installation

    In such tion, completely fill the bearings with grease or moisture- cases, IMH fans of all arrangements should be installed on inhibiting oil (refer to Lubricants, page 6). Also, store the either rails or bases in the classical orientation. Typically,...
  • Page 3: Wiring Installation

    For 3-phase motors, if the fan is running in the wrong direction, check the control switch. It is possible to interchange two leads at this lo- cation so that the fan is operating in the correct Discharge Duct Turns direction. IMH IO&M B51221-002...
  • Page 4: Wiring Diagrams

    J-10 J-10 mum, this must be a Premium Efficiency motor with Class Low Voltage F insulation. Motors that are not supplied by Loren Cook Ground B Ground B Company should have the recommendation of the motor When ground is required, attach to ground A or B with No. 6 thread manufacturer for use with a VFD.
  • Page 5: Pulley Alignment

    8 hour and 24 hour intervals of satisfactory opera- tion. During the inspections, stop the fan and inspect as per the Conditions Chart. 30 Minute Interval Inspect bolts, setscrews and motor mounting bolts. Adjust and tighten as necessary. IMH IO&M B51221-002...
  • Page 6: Maintenance

    It is recommended that the intervals should be halved. conditions and location of the fan. Loren Cook Company uses petroleum lubricant in a lithium Inspect fans exhausting corrosive or contaminated air base. Other types of grease should not be used unless the bear- within the first month of operation.
  • Page 7: Troubleshooting

    Remove bearing hold-down bolts. Remove shaft and bearings as one unit. • Improper bearing lubrication Remove anti-corrosion coating from the shaft with a suit- • Excessive belt tension. able degreaser. Remove the bearing from the shaft using a bearing puller. IMH IO&M B51221-002...
  • Page 8: Parts List Arrangement

    Cook Company, General Offices, 2015 East Dale Street, Springfield, Missouri 65803-4637, explaining in writing, in detail, your complaint and referring to the specific model and serial numbers of your fan. Upon receipt by Loren Cook Company of your written complaint, you will be notified, within thirty (30) days of our receipt of your complaint, in writing, as to the manner in which your claim will be handled.

Table of Contents