If the range hood or lights does not
operate after installation:
Check if the range hood has been plugged in, make sure that all
power has been turned back ON, the fuse is not blown and all
electrical wiring is properly connected.
Swap out light assembly to working ones to deter• mine whether
it is caused by defective bulbs. See replacing the light bulbs on
Page 13.
The range hood vibrates when the
blower is on:
The range hood might not have been secured properly on to the
ceiling or wall.
Check if the motor is secured in place. If not, then tighten the
motor in place. Check if the blower wheel is a damaged.
The blower or fan seems weak:
Check that the duct sized used is at least 6". Range hood
WILL NOT function efficiently with insufficient duct size & loosely
secured.
Check if duct is clogged or if damper unit (half-circular flapper)
is not installed correctly or opening properly. A tight mesh on a
side wall cap unit might also cause restriction to the air flow.
The lights work but the blower is not
spinning at all, is stuck or is rattling.
The blower might be jammed or scraping the bottom due to
2 5