In the unlikely event in Australia or New Zealand that this Davey product develops any malfunction
within two years of the date of original purchase due to faulty materials or manufacture, Davey will at
our option repair or replace it for you free of charge, subject to the conditions below.
Should you experience any difficulties with your Davey product, we suggest in the first instance that
you contact the Davey Dealer from which you purchased the Davey product. Alternatively you can
phone our Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or
send a written letter to Davey at the address listed below. On receipt of your claim, Davey will seek to
resolve your difficulties or, if the product is faulty or defective, advise you on how to have your Davey
product repaired, obtain a replacement or a refund.
Your Davey Two Year Guarantee naturally does not cover normal wear or tear, replacement of product
consumables (i.e. mechanical seals, bearings or capacitors), loss or damage resulting from misuse
or negligent handling, improper use for which the product was not designed or advertised, failure to
properly follow the provided installation and operating instructions, failure to carry out maintenance,
corrosive or abrasive water or other liquid, lightning or high voltage spikes, or unauthorized persons
attempting repairs. Where applicable, your Davey product must only be connected to the voltage
shown on the nameplate.
Your Davey Two Year Guarantee does not cover freight or any other costs incurred in making a claim.
Please retain your receipt as proof of purchase; you MUST provide evidence of the date of original
purchase when claiming under the Davey Two Year Guarantee.
Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, damage
or injury of any kind whatsoever arising directly or indirectly from Davey products. This limitation
does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to
your Davey product under the Australian or New Zealand legislation and does not affect any rights or
remedies that may be available to you under the Australian or New Zealand Consumer Legislation.
In Australia, you are entitled to a replacement or refund for a major failure and for compensation for
any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major
failure.
Should your Davey product require repair or service after the guarantee period; contact your nearest
Davey Dealer or phone the Davey Customer Service Centre on the number listed below.
For a complete list of Davey Dealers visit our website (davey.com.au) or call:
AUSTRALIA
Customer Service Centre
6 Lakeview Drive,
Scoresby, Australia 3179
Ph:
1300 367 866
Fax:
1300 369 119
Website: davey.com.au
Davey Water Products Pty Ltd
Member of the GUD Group
ABN 18 066 327 517
® Davey & Torrium2 are registered trade marks of Davey Water Products Pty Ltd.
© Davey Water Products Pty Ltd 2011.
* Installation and operating instructions are included with the product when purchased new.
They may also be found on our website.
NEW ZEALAND
Customer Service Centre
7 Rockridge Avenue,
Penrose, Auckland 1061
Ph:
0800 654 333
Fax:
09 527 7654
Website: daveynz.co.nz
P/N 400280-11 supersedes P/N 400280-10
Installation and
Operating Instructions
for Davey XP/T & XJ/T
Pressure Systems with
NOTE: Prior to installation remove the inlet and outlet
pipe transport plugs & associated seals from the
suction and/or discharge ports.
WARNING : The Torrium2
controller, pump and associated pipework
®
operate under pressure. Under no circumstances should the Torrium2
controller, pump or associated pipework be disassembled unless the
internal pressure of the unit has been relieved. Failure to observe this
warning will expose persons to the possibility of personal injury and may
also result in damage to the pump, pipework or other property.
WARNING: Failure to follow these instructions and comply with all applicable
codes may cause serious bodily injury and/or property damage.
Please pass these instructions on to the operator of this equipment.
®

Advertisement

loading

Summary of Contents for Davey Davey XP/T

  • Page 1 Customer Service line on 1300 367 866 in Australia, or 0800 654 333 in New Zealand, or send a written letter to Davey at the address listed below. On receipt of your claim, Davey will seek to resolve your difficulties or, if the product is faulty or defective, advise you on how to have your Davey product repaired, obtain a replacement or a refund.
  • Page 2 Davey pressure system is designed to handle clean water. The system should not be used for any other purpose without specific referral to Davey. The use of the system to pump flammable, corrosive and other materials of a hazardous nature is specifically excluded.
  • Page 3 This is more likely to occur when boosting mains pressure. Should this Pressure occur, re-prime your pump unit. Should this not prove successful, it is likely you have Indicator a blockage in the pump. You should contact your Davey dealer for assistance. Window NOTE: Rotary Coupling Inlet...
  • Page 4: Maintenance

    Choose a site with a firm base and as close to the water source as possible with d) MOTOR STOPS - YELLOW STATUS INDICATOR LIGHT IS ILLUMINATED. correct power supply. Make sure your pressure system is always connected to an 1. Motor ”over temperature” cut-out tripped. Consult Davey dealer. adequate, reliable source of clean water. 2. Motor not free to turn - e.g. a jammed impeller. Consult Davey dealer. 3. Prime button has been held in for too long. Release prime button and Housing your Davey Pressure System switch off power for 1 minute to allow unit to reset. 4. Your Torrium2 has detected high water temperature in the pump. Once the ® To protect your pressure system from the weather, make sure the water has cooled the Torrium2 will automatically restart the pump. ®...
  • Page 5: Power Connection

    In accordance with AS 3350.2.41 we are obliged to inform you that this pump is not 5. If the pump stops with the tap open to be used by children or infirm persons and must not be used as a toy by children. see troubleshooting checklist. NOTE: For protection, the Davey pump motors are fitted with an automatic 6. Close the open outlet or tap and reset thermal overload, constant tripping of this overload indicates a the pump should stop after a few problem e.g. low voltage at pump, excessive temperature (above 50°C) in 2. Ensure outlet nearest...
  • Page 6 Where to use Check Valves and Foot Valves Do not use pipe thread sealing compounds on any part of this pump. ONLY The Torrium2 controller has an inbuilt non-return (check) valve fitted. In flooded ® use Teflon sealing tape. suction installations there is no need to have a suction non-return valve. In suction lift installations a footvalve will normally be required for the pump to Use unions at pipe connections to enable easy removal retain prime. and servicing. Use sufficient tape to ensure airtight seal and hand tighten only. To prevent strain on pump threads In some suction lift installations there may be good reason to remove the inbuilt always support heavy inlet and outlet pipes. If there is check valve to ensure that the discharge pressure is also applied to the suction line a likelihood the water supply may contain solid particles and footvalve. This could be where the suction line was very long or where there such as pieces of plant or vegetable matter, a filter should was concern regarding a leaking footvalve. This may not always be applicable and be installed before the pump to avoid blocking of water...