KNX A3-B2
Door Operator Control Module
Item number 70391
Installation and Adjustment

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KNX A3-B2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for elsner elektronik KNX A3-B2

  • Page 1 KNX A3-B2 Door Operator Control Module Item number 70391 Installation and Adjustment...
  • Page 3: Table Of Contents

    5.3. Input 1 / 2 ........................ 10 Elsner Elektronik GmbH • Sohelngrund 167 • 75395 Ostelsheim • Germany Door operator control module KNX A3-B2 • from software version 1.00, ETS programme version 1.0 Status: 17.12.2019 • Subject to technical changes. Errors excepted.
  • Page 4 Clarification of signs Installation, inspection, commissioning and troubleshooting of the device must only be carried out by a competent electrician. This manual is amended periodically and will be brought into line with new software releases. The change status (software version and date) can be found in the contents footer. If you have a device with a later software version, please check www.elsner-elektronik.de in the menu area "Service"...
  • Page 5: Description

    5 m Outputs 3 x semi-conductor output (open collector) max. 60 V AC/DC, 300 mA. For safety extra-low voltage according to the SELV specifications only! Door operator control module KNX A3-B2 • Version: 17.12.2019 • Technical changes and errors reserved.
  • Page 6: Installation And Start-Up

    Elsner Elektronik is not liable for any changes in norms and standards which may occur after publication of these operating instructions. 2.2. Installation 2.2.1. Installation location Install and operate in dry interior rooms only! Avoid condensation. Door operator control module KNX A3-B2 • Version: 17.12.2019 • Technical changes and errors reserved.
  • Page 7: Connection/ Layout Of The Circuit Board

    (not connected) black output 2 yellow output 2 black (not connected) white output 1 black output 1 Connection of the outputs independent from polarity. Door operator control module KNX A3-B2 • Version: 17.12.2019 • Technical changes and errors reserved.
  • Page 8: Notes On Mounting And Commissioning

    The device is supplied with the bus address 15.15.250. You can program another ad- dress into the ETS by overwriting the 15.15.250 address or by teaching via the pro- gramming button. Door operator control module KNX A3-B2 • Version: 17.12.2019 • Technical changes and errors reserved.
  • Page 9: Transmission Protocol

    Input 1 Scene Output 18.001 R CT Input 2 Extended Input/Output 1.008 RWCT Input 2 Short Output 1.010 R CT Input 2 Switching Input/Output 1.001 RWCT Door operator control module KNX A3-B2 • Status: 17.12.2019 • Technical changes and errors reserved.
  • Page 10: Parameter Setting

    Select whether output 3 is a normally closed or normally open contact (duration of opening/closing 1 second). Operating mode Defined Open/Closed/Stop Allows control of one door Door operator control module KNX A3-B2 • Status: 17.12.2019 • Technical changes and errors reserved.
  • Page 11 In addition, monitoring can be set. After the monitoring period, the object is set to 0 (unless a new 1 signal is received), i.e. the output is opened: Door operator control module KNX A3-B2 • Status: 17.12.2019 • Technical changes and errors reserved.
  • Page 12: Input 1 / 2

    • send 0 • send 1 • do not send telegram Command when releasing the button • send 0 • send 1 • do not send telegram Door operator control module KNX A3-B2 • Status: 17.12.2019 • Technical changes and errors reserved.
  • Page 13 Dimmer Button function brighter • darker • brighter/darker Time between switching and dimming 1...50; 5 (in 0.1 s) Repeat the dimm command no • yes Door operator control module KNX A3-B2 • Status: 17.12.2019 • Technical changes and errors reserved.
  • Page 14 Button operation • without saving • with saving Time between calling and saving in 0.1 1...50; 10 seconds (only if selected "with saving") Scene No. 0...127 Door operator control module KNX A3-B2 • Status: 17.12.2019 • Technical changes and errors reserved.
  • Page 15 Release before time 1 expired: step (or stop if drive is moving) Point in time 1: End of time 1, start of time 2 Moving command Door operator control module KNX A3-B2 • Status: 17.12.2019 • Technical changes and errors reserved.
  • Page 16 The drive moves as soon as the button is actuated and stops as soon as the button is released. Control mode Dead man's switch Behavior during button operation: Push button = Up or Down command Release button = Stop command Door operator control module KNX A3-B2 • Status: 17.12.2019 • Technical changes and errors reserved.
  • Page 18 Elsner Elektronik GmbH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone +49 (0) 70 33 / 30 945-0 info@elsner-elektronik.de Germany +49 (0) 70 33 / 30 945-20 www.elsner-elektronik.de Technical support: +49 (0) 70 33 / 30 945-250...