MECHANICAL
2.200
TYPE AA
1.350
BATTERY
M880
HEAT
3.125
SINK
.250
2.750
ELECTRICAL
5
9
4
Remote "Control" switch 28VDC activates
8
3
7
2
6
28 Volts
1
GND
SPECIFICATIONS
• GMT full 6 digit, hours/ minutes/ seconds
• Local Time 24 hour, 4 digit
• Four Digit Elapsed Time count up starts
minutes, seconds then hours and minutes
up to 99:59
• Elapsed Time count down settable from
one second to 59 minutes 59 seconds
• Elapsed Time Alarm activates at zero
when counting down and ashes display
3.885
M 8 8 0 A
TYP 45°
CHRONOMETER
4 PL.
G
M
T
3.175
DIM
GMT LT
ET
SELECT
CONTROL
D A V T R O N
4-40 CS
82° TYP
4 PL.
• N.V.G. compatible
• Battery type AA alkaline
• Input Current 500ma
• Input Voltage 28 volts D.C.
• Weight 10 oz.
• Warranty one year
427 HILLCREST WAY
REDWOOD CITY (EMERALD HILLS), CA 94062
(650) 369-1188
www.davtron.com
NVG DIGITAL CLOCK
Full six-digit GMT clock
Universal & Local Time
Elapsed Time - Count Up / Count Down Alarm
M880A
BG7B
NVG Compatible Display
FEATURES
•Two-button control system is natural and
error-free. Setting operations are identical
for all features US Patent #4,486,077
•Control switch has remote capability
•Incandescent displays
•N.V.G. f i lter
•Manual dimming of the display
M880A-S
GREEN A
•Full 6 digit display selectable GMT/Local
•Time/Elapsed Time
•Elapsed Time is count up or down
•A 4 Megahertz crystal precision time
reference
•Keep alive battery with 2 year life

Advertisement

loading

Summary of Contents for Davtron M880A

  • Page 1 GMT LT SELECT CONTROL D A V T R O N 4-40 CS 82° TYP 4 PL. .250 2.750 M880A M880A-S ELECTRICAL Remote “Control” switch 28VDC activates 28 Volts BG7B GREEN A SPECIFICATIONS NVG Compatible Display • GMT full 6 digit, hours/ minutes/ seconds •...
  • Page 2 M880A DIGITAL CLOCK CLOCK OPERATION Normal Operation Elapsed Time Count Up The SEL button selects what is to be displayed Select ET for display. Pressing the CTL button on the four digit window and the CTL button will start ET counting. Elapsed Time counts up controls what is being displayed.