ClimateWorx Series Maintenance Manual

Advertisement

Quick Links

Maintenance Guide
ClimateWorx International Inc.
Maint-CL2016.doc
14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ClimateWorx Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ClimateWorx ClimateWorx Series

  • Page 1 Maintenance Guide ClimateWorx International Inc. Maint-CL2016.doc 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4...
  • Page 2 Vertical Floor /Wall /Ceiling Mount - Maintenance Manual Maint-CL2016.doc...
  • Page 3 Vertical Floor /Wall/Ceiling Mount - Maintenance Manual TABLE OF CONTENTS MAINTENANCE GENERAL SERVICE AND INSPECTION REGULAR INSPECTION SENSOR CALIBRATION CHECK PREVENTIVE MAINTENANCE: QUARTERLY REPLACEMENT OF AIR FILTERS MICROPROCESSOR CONTROLLER POWER PANEL COMPRESSOR LUBRICATION COOLING COIL AND REFRIGERATION SYSTEM CONDENSER ELECTRIC MOTOR BLOWER FAN ELECTRIC HEATER HUMIDIFIER...
  • Page 4 Vertical Floor /Wall /Ceiling Mount - Maintenance Manual MAINTENANCE The ClimateWorx Series Vertical Floor Mount family computer room air-conditioning unit employs carefully selected components of proven quality to ensure prolonged trouble-free operations. Maintenance-free solid state controllers also enhance the reliability of the whole system.
  • Page 5 Vertical Floor /Wall/Ceiling Mount - Maintenance Manual 3. Switch unit on, wait 60-120 seconds, and login to security level 1. Go to the sensor page under the [Test mode] tab, press the “Def.” and then “Set 0” key next to the temp1 reading. The Temp1 reading should now read 0°...
  • Page 6 The state-of-art solid state microprocessor based controller is virtually trouble free and little or no maintenance is needed. Quarterly checks of the following are recommended for efficient operation of the machine. To control individual operations refer to ClimateWorx User Guide pages 34 to 36. Note: The fan must be kept running through individual tests.
  • Page 7 Vertical Floor /Wall/Ceiling Mount - Maintenance Manual If the oil level in the sightless of the compressor is less than one-eighth (1/2) up from the bottom of the glass, this indicates a low oil level. If the oil level is up more than one-half (3/4) from the bottom, his indicates a high oil level.
  • Page 8 Vertical Floor /Wall /Ceiling Mount - Maintenance Manual BLOWER FAN Special design blower fans with strengthened bearing and mounting arrangement driven by double belt pulley system is our standard design. Regular maintenance should include: Check motor current and bearing. Check fan belt tension and adjust where necessary. Check fan bearing for noise and wear and tear for twin blower unit.