Brannstrom Sweden AB Uddevallagatan 14 416 70 Gothenburg, Sweden Tel: +46 (0)31 195600 Fax: +46 (0)31 197790 Email: info@brannstrom.se Operations and Technical manual for Oil Discharge Monitoring Equipment CleanTrack 1000 B (Revision 2.20xd for Software version 2.20x)
4.3.7. Piping for Air motor (Air motor option only) ..............20 4.4. Flow meter and Speed log ........................21 4.4.1. Flow meter general ......................21 4.4.2. BRANNSTROM standard flow transmitter............... 21 4.4.3. Speed log general ....................... 21 4.5. Paper Printer ............................22 4.6.
Page 3
9.8.4.4. Air motor Sample pump, Speck Y2951 9.8.5. Fuses ..........................94 9.9. Recommended Spare parts ........................95 9.10. Consumables ............................95 9.11. Storage before installation ........................95 10. Figures and Drawings ........................96 Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 3 of 232...
Page 4
12.9. Sample Pump, Speck pump with Gast air motor ................228 13. Appendix, Work shop test and Calibration Certificate ..............229 14. Project specific drawings and data sheets ..................231 Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 4 of 232...
1. Introduction The Oil Discharge Monitoring System, CleanTrack 1000 B, has been designed to provide means of monitoring, recording and controlling the ballast discharge in accordance with the requirements in Resolution MEPC.108(49) as amended by Resolution MEPC.240(65) and is also approved for Bio- fuel blends in accordance with MEPC.1/Circ.761 as revised.
Brannstrom Sweden AB. 2.2. Disclaimer and Conditions All information provided by Brannstrom Sweden AB about this equipment is given in good faith and is based on the best knowledge available at the particular time. No responsibility is, however, assumed for possible inaccuracies or omissions.
New “Declaration of Conformity”, issued 2019-01-02. Chapter 12.1. Declaration of Conformity page 166. 3. Specification 3.1. Description Type CleanTrack 1000 B Application Oil Discharge Monitoring and Control System for Oil Tankers in accordance with MEPC.108(49) as amended by Resolution MEPC.240(65), approved for Crude oils and Petroleum products as well as for 10 types of Bio-fuel blends in accordance with MEPC.1/Circ.761 as revised.
Signals from non-oil contaminants can be compensated for due to their different light scattering characteristics. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019...
Voltage 85-265 VAC Frequency 50/60 Hz Consumption 30 W Ingress Protection IP42 Ambient Temp. 5 - 50 °C Weight ~7 kg Dimensions approx. 370 x 210 mm Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 9 of 232...
Page 10
If unit is powered through a frequency converter measurement might be faulty. For setting, see chapter 7.8.9. System Configuration, Alarms&Extras page 71. See also drawing CTB10003 sheet 4 of 4, Converting Unit page 103. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 10 of 232...
Page 11
See 4.c. below for more information about the Sample pump If sample temperature is higher than the ambient temperature limit the limit becomes lower or cabinet should be ventilated. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 11 of 232...
Page 12
See chapter 12.9. Sample Pump, Speck pump with Gast air motor page 228. If sample temperature is higher than the ambient temperature limit the limit becomes lower or cabinet should be ventilated. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019...
Measuring range 0-16 bar (any range 0-10 bar to 0-25 bar can be used) Sample connection G½” male thread Ex. Class must comply with the particular hazardous area Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 13 of 232...
Interface for intrinsically safe communication between the Zener barrier and the Measuring cell. Interface for intrinsically safe flow meter only. Interface for intrinsically safe pressure transmitter only. Interface for intrinsically safe potential free contact. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 14 of 232...
4. Installation This chapter contains advice for the installation of CleanTrack 1000 B equipment on board tankers. The advice given in this chapter is of general validity and should be supplemented with a detailed installation specification for the particular ship. Additionally, all applicable regulations regarding the installation standard, issued by the relevant authorities and classification society must be followed.
Keep Cb7 and other cables connected to intrinsically safe circuits separated from non-intrinsically safe circuit cables. Data communication between Converting Unit and Analyzing Unit, Cb7: Baudrate: 19200 baud. Length: ≤50 meters. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 16 of 232...
CTB10010 sheet 3 of 5, Analyzing unit with air motor sample pump page 116. • CTB10010 sheet 5 of 5, Analyzing unit with air motor sample pump page 118. • Chapter 10.7. Connection box page 126 • Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 17 of 232...
The sample feed pump may be damaged if run dry for more than 10 seconds. The sample valves and sample inlet filter should be located with adequate space and accessibility for servicing. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019...
The water consumption is about 200 to 600 l/h and is open about 45 seconds at start-up. It is also recommended to flush manually at closing down. This makes about 6-20 liters per start/stop. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019...
The calculation is for a straight pipe, pressure drops at bends has not been taken in account. Make own calculations and have margin to allow the pressure regulator to work properly. Pressure(final) = 5.2 bar (pipe inner diameter, [mm]) Initial pressure, [bar] Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 20 of 232...
Refer to chapter 7.8.7. Speed page 70 for software programming. The speed log signal connected to CleanTrack 1000 B should be a pulse signal from a voltage free relay or switch. The pulse frequency should be proportional to the speed.
Nominal flow of some sample pumps: Sample pump with Ex motor (SPP-100) 600 l/h Bulk head mounted (Nikuni or Matre): 900 l/h Sample pump with air driven motor: 240 l/h Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 22 of 232...
Converting Unit (Cb5), GPS input (Cb29) and Log input (Cb12) if speed log is used. Connect mains to the computer unit. After a few seconds 2 different “Brannstrom Sweden” will appear on the screen before the screen goes black again and about 2 minutes later the Cleantrack1000B software appears.
The limits for fresh water are however not essential the same way as the sample limits are. 13. When finished following the relevant steps in the 5.3. Close down procedure page 39. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 24 of 232...
Also check the temperature class of installed intrinsically safe apparatus and if the specified zone is acceptable. Concerning cables to intrinsically safe equipment the writing in the standard, IEC 60079-14, is: Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019...
Page 37
200 pF/m and either 1 μH/m or 30 μH/Ω where the interconnection comprises two or three cores of a conventionally constructed cable (with or without screen).” Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 37 of 232...
• Check that power is connected to the Converting unit. • If installed, check that the sample pump disconnector switch is ON. If the sample pump is powered by an air motor: Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 38 of 232...
Carefully blow dry with air, make sure not to exceed the pressure ratings. For more details, see the DP transmitter maker’s instructions. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 39 of 232...
Page 40
Drain any part of the fresh water piping (if installed) which could be subjected to sub- zero temperatures. 13. The measuring cell can be disconnected and removed. If so, clean it, and store it in a dark, dry and temperature controlled location. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 40 of 232...
Set LCD background light intensity. A press to the left gives a darker display and to the right a brighter display. Submenu select keys, described below. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 41 of 232...
The key can change the displayed menu, open a submenu, open a drop-down list or simply change color to yellow as an indication of activation. An example of a submenu is this verification menu which opens when the "Manual Override Discharge Valve" key is pressed: Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 42 of 232...
The most commonly used passwords are the ones needed to enter sub menus from the “Main Menu” “Setup” – Password “3” and “Admin” • • “Computer” – Password “1” and “User” • “System check” – Password “2” and “Admin” Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 43 of 232...
"D1 Flashing SINGLE, D2 Flashing DOUBLE" - Waiting for KB to be pressed MC-D1 MC-D2 "D1 Flashing DOUBLE, D2 Flashing SINGLE" - Waiting for KA to be pressed MC-D1 MC-D2 Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 44 of 232...
7.1.1. Start page If the touch screen is inactive for more than about 30 minutes the “Start page” will be shown. Select “Continue” to go to the “Main Menu”. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 45 of 232...
Option for an “Extended” converting unit. A table showing sample pump motor data. “Show Motor” Option for an “Extended” converting unit. Showing the “Conv. Unit” table above. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 46 of 232...
Discharge line popup menu. (This popup menu will differ depending on selections made in Chapter 7.8.1. Line of discharge page 67) "#1", "#2", "#3" or “#4” Select line for discharging. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 47 of 232...
Oil types “Automotive Gasoline”, “Kerosene” and “Mar.Dist FO – DMA” are according to "White petroleum products" in MEPC.108(49). The bio-fuel blended types are in accordance with MEPC.1/Circ.761 and MEPC.240(65) and Annex 11 of MEPC.2/Circ.23. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 48 of 232...
Page 49
Bio-fuel blends of Kerosene and Alkanes (C10-C17), linear and branched C10-C17 (>75% but <99% Kerosene by volume) 1%-25% Alkanes Bio-fuel blends of Naphtha and Tert-Amyl ethyl ether Tert-Amyl ethyl ether (>75% but <99% Naphtha by volume) Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 49 of 232...
Page 50
No.4 Crude Oil Lubrication oil No.4 Crude Oil Heavy fuel oil No.6 Crude Oil Kerosene and JP1 jet fuel Kerosene Gasoline and JP4 type jet fuel Automotive Gasoline Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 50 of 232...
Display of the 1800 seconds (30 minutes) countdown timer that which automatically resets all of the 4 manual selections “Manual Oil conc”, “Manual Flow”, “Manual Speed” and “Manual Position” to automatic mode again. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 51 of 232...
Only to be used in case of motor sensor malfunction. This selection needs to be verified on a popup window. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 52 of 232...
Resetting alarms. Status columns indicates "ACTIVE" for alarm not yet resets and "RESET" for remaining alarms already reset. "Operate" Go to "Operate page". "MENU" Go to "Main Menu". Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 53 of 232...
The indication (MaR) after “Conc” indicate that the Oil Concentration was set to manual after starting for discharge, (in “RUNNING” mode). Then the sample pump is started and normal pressure checks are made. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019...
Line 126751 show that overboard valve control is set back to automatic. Line 126752 show with the initial “\Alarm” the time that the alarm overboard valve in manual is deactivated. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 55 of 232...
(Most memory sticks are preformatted with FAT32) For information regarding Recorded data see chapter 7.4.1. Recorded data examples page 55. 7.5.1. USB-Memory stick Indications before a USB-Memory stick is inserted. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 56 of 232...
Page 57
If the USB-stick is removed before this key is pressed, power must be switched off and on again before the Computer Unit can recognize a USB-stick again. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 57 of 232...
7.5.2. Save Printouts on USB stick If the printer file “CTB-####_printer.txt” already exist on the USB-stick an overwrite verification popup is displayed. Select how many printouts to save on the USB-stick. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 58 of 232...
An external malfunction can be checked by disconnecting power to the converting unit. Then communication alarms will be raised. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 59 of 232...
Page 60
30 liters per nautical mile; Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 60 of 232...
Page 61
Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 61 of 232...
Page 62
The check should be made at a flow rate of about 50% of the rated flow of the flow meter. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019...
Selection if the Zero Calibration Result is used in the concentration calculations. Graphs "Last Successful Zero" Displays the values from the last successful zero. "Is values" Displays the measured values. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 63 of 232...
Water Valve". If "No Controlled Water Valve" is selected in the Setup/Config-page this key is not visible. "Zero Prepare" Press this key to start preparations for Zero Check/Calibration. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 64 of 232...
"Square indication" Indicates the result of the Check/Calibration, red = fail / green = ok. "Graph indication" See explanation 2 pages up when where Status is explained. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 65 of 232...
The instructions on the 2 pages below describes how the Measuring Cell is replaced and the tools needed. Before replacing the measuring cell, study the chapter 4.10. Measuring Cell Instructions and Replacement page 30. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019...
Open a key in “Operate”-menu to manually control the slop tank valve output. Relay output on terminals 3 and 4 in computer unit controls the overboard valve. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 67 of 232...
"Square root" NO if current is linear to flow, YES if current is linear to pressure. 7.8.3. ZF2 Same as ZF1 above. 7.8.4. CVF Same as ZF1 above. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 68 of 232...
“pressure increase”<“Water Low limit” for 10 seconds the “Alarm – Low Water Pressure” is activated. Any of these 2 alarms will stop the unit and close the water valve. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 69 of 232...
An alarm for sample pump contactor feedback in wrong position will be raised again at every touch screen timeout (about 30 minutes). This alarm is always checked for units with serial number CTB 2892 and later. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 71 of 232...
Page 72
"$PCTB","Recorded data line","*",2 bytes checksum,Carriage Return,Line Feed. Baudrate=4800, Parity=None, Data bits=8. "Contact Information" Contact information can be displayed in the "Start menu" and in the "Alarm table". Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 72 of 232...
7.9.2. Real Time Clock Setting of the Real Time Clock. Clock shall be set to GMT-time. The clock can be set manually or to the time read from the GPS. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 73 of 232...
If the calibration is successful the new calibration should be in effect directly after exit from the calibration screen. In some cases, the unit has to be restarted. Do this by disconnecting power and connecting it back on again. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019...
Press to activate. When activated, relay outputs of other printed circuit boards in the system can be manually activated. Take caution when starting the sample pump, pressure alarms are disabled. Password: "8378" and "Admin". Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 75 of 232...
Item d2 on drawing: CTB10001p sheet 3, Computer Unit with open door page 98. "PrinterCommStatus" Communication status with the paper printer module. "ActivateWinder" Activate the paper rewinder. "Print test line" Makes a test printout to the paper printer. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 76 of 232...
Relay outputs of the power supply "PowerFlags" Software version, temperature and flags status of the power supply. "PowerTxData" Transmit data to the power supply. "PowerRxData" Received data from the power supply. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 77 of 232...
"CVCT_In" Software version, digital inputs and current input of the CVCT PCB. "CVCT_TxData" Transmit data to the CVCT PCB. "CVCT_RxData" Received data from the CVCT PCB. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 78 of 232...
Software version, digital inputs ZD1 - ZD4, analogue input of channels ZP, ZF1 and ZF2. Voltage levels and temperature on the ZBCT PCB. "ZBCT_TxData" Transmit data to the ZBCT PCB. "ZBCT_RxData" Received data from the ZBCT PCB. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 79 of 232...
Modbus RTU communication over an RS485 channel on the CUIO PCB in the Computer unit. Intended for communication with the Cargo Control system. This option is not further described in this manual. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019...
If adaption for additional bio-fuels is needed, another serial number specific activation password can be purchased from an authorized agent. Select the “Upgrade” key and insert the activation password in the popup menu. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 81 of 232...
File system error indicating a compatibility error in “Valve Control” of “Line” data in the “Setup” menu. Settings “EL1/EL2” and “EL1/EL2-n” can only coexist together with “None”. Reprogram this setting or consult a service engineer for corrective actions. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 83 of 232...
Check the flat cable connections inside the Computer unit. "18 System - Replaced Measuring Cell?" If the Measuring Cell is replaced while power is connected to the Computer Unit, it will give this alarm. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 84 of 232...
The slop tank valve is controlled by the “EL2” relay output in the computer unit. Check the fuse(s) for the relay output the feedback connections. “29 Alarm - GPS Speed timeout” Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 85 of 232...
Indicates a problem on the outlet side of the analyzing unit. “RUNNING” mode is stopped. See chapter 7.8.5. Pressure, page 69 and 7.8.8. System Configuration, Standard, page 71. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 86 of 232...
Printer buffer has overflow. Printer busy do not work, check cable connections to the printer. If this alarm remains the printer and/or the CUIO PCB connected to the printer need to be replaced. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019...
The work pressure low limit is exceeded 5 seconds after the sample pump was stopped. A possible reason is that the sample pump is not stopped due to a malfunction in the sample pump control. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019...
Page 89
See chapter 7.8.9. System Configuration, Alarms&Extras page 71. Connect disconnector switch feedback to terminals 13, 14 on the Converting unit I/O pcb. Set the disconnector switch to “ON” when the unit is in use. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 89 of 232...
0.5 Hz Modbus Modbus Receive Transmit PCB located in the Converting unit, see CTB10003 sheet 3 of 4, Converting Unit page 102, d5. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 90 of 232...
Measuring cell transmit Measuring Measuring cell cell receive comm. ok PCB located in the Converting unit, see CTB10003 sheet 3 of 4, Converting Unit page 102, d6. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 91 of 232...
If paper printer: check the amount of printer paper that is left and replace the roll if necessary, for safeguarding uninterrupted operation during next discharge. Consider to store “Recorded data” on a USB-memory stick. See chapter 7.5.1. USB-Memory stick page 56. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 92 of 232...
See chapter 8.1. Malfunction of Computer/Converting unit page 82. 9.5. Verification of accuracy and access to restricted parts User access to the Measuring cell is restricted with seals, which only Brannstrom Sweden AB can replace, in order to comply with clause 5.1 of MEPC. 108(49).
Paper roll diameter: max 50 mm. Cleaning Brush Cleaning brush for CleanTrack 1000 B (cleaning of glass pipe in Measuring Cell). 9.11. Storage before installation Prior to installation the unit should be stored in a tempered and dry location protected from sunlight.
This chapter contains standard drawing alternatives and options. For project specific drawings, refer to chapter 14. Project specific drawings and data sheet page 231. The rest of the page is intentionally left blank. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 96 of 232...
10.1. Computer Unit Drawing: CTB10030 sheet 1, Computer Unit mounting Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 97 of 232...
Page 98
Drawing: CTB10001p sheet 3, Computer Unit with open door. Note: printer is optional. Standard version is without items d2 and d3. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 98 of 232...
Page 99
Drawing: P3715090 sheet 1, Computer Unit panel mount instructions. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 99 of 232...
10.3. Analyzing Unit 10.3.1. Analyzing Unit skid with Ex. motor Sample pump Drawing: CTB10015 sheet 1 of 3, Analyzing unit skid with electrical Ex. motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 104 of 232...
Page 105
Drawing: CTB10015 sheet 2 of 3, Analyzing unit skid with electrical Ex. motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 105 of 232...
Page 106
Drawing: CTB10015 sheet 3 of 3, Analyzing unit skid with electrical Ex. motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 106 of 232...
10.3.2. Analyzing Unit with external Sample pump Drawing: CTB10014 sheet 1 of 5, Analyzing unit with external sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 107 of 232...
Page 108
Drawing: CTB10014 sheet 2 of 5, Analyzing unit with external sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 108 of 232...
Page 109
Drawing: CTB10014 sheet 3 of 5, Analyzing unit with external sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 109 of 232...
Page 110
Drawing: CTB10014 sheet 4 of 5, Analyzing unit with external sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 110 of 232...
Page 111
Drawing: CTB10014 sheet 5 of 5, Analyzing unit with external sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 111 of 232...
10.3.4. Analyzing Unit with Air motor Sample pump Drawing: CTB10010 sheet 1 of 5, Analyzing unit with air motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 114 of 232...
Page 115
Drawing: CTB10010 sheet 2 of 5, Analyzing unit with air motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 115 of 232...
Page 116
Drawing: CTB10010 sheet 3 of 5, Analyzing unit with air motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 116 of 232...
Page 117
Drawing: CTB10010 sheet 4 of 5, Analyzing unit with air motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 117 of 232...
Page 118
Drawing: CTB10010 sheet 5 of 5, Analyzing unit with air motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 118 of 232...
10.9. GA-plans 10.9.1. Partnames of typical arrangement Drawing: CTB10601 sheet 1 of 1, Partnames of typical arrangement. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 129 of 232...
10.9.2. GA-plan with Ex. motor Sample pump Drawing: CTB10907 sheet 1 of 1, GA-plan with skid Ex. motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 130 of 232...
Page 131
Drawing: CTB10917 sheet 1 of 1, GA-plan with skid Ex. motor sample pump and flushing. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 131 of 232...
Page 132
Drawing: CTB10908 sheet 1of 1, GA plan with free standing Ex. Motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 132 of 232...
10.9.3. GA-plan with bulkhead penetrating Sample pump Drawing: CTB10906 sheet 1 of 1, GA-plan with bulkhead penetrating Sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 133 of 232...
Page 134
Drawing: CTB10916 sheet 1 of 1, GA-plan with bulkhead penetrating Sample pump and flushing. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 134 of 232...
10.9.4. GA-plan with Air motor Sample pump Drawing: CTB10901 sheet 1 of 1, GA-plan with air motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 135 of 232...
Page 136
Drawing: CTB10911 sheet 1 of 1, GA-plan with air motor Sample pump and flushing. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 136 of 232...
10.9.5. GA-plan with pilot-controlled Air motor Sample pump Drawing: CTB10903 sheet 1 of 1, GA-plan with pilot-controlled air motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 137 of 232...
10.10.3. Electrical cable diagram for air motor sample pump Drawing: CTB110204.1pn, electrical cable diagram for air motor sample pump. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 140 of 232...
10.10.4. Internal cable diagram for electrical sample pump motor Drawing: CTB110627.1el, internal cable diagram for electrical sample pump motor. Include wires 008 and 009 for sample pump contactor feedback. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 141 of 232...
10.12. Flow meter Drawing: CT891215.5, CleanTrack Flow meter unit, Vertical. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 145 of 232...
Page 146
Drawing: CT900503.1, CleanTrack Flow meter unit, Horizontal. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 146 of 232...
Page 147
Drawing: CT050505.1, CleanTrack Flow transmitter bracket. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 147 of 232...
12.8. Sample Pump, SPP-100 with Elprom explosion proof motor 12.8.1. Elprom instructions Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 201 of 232...
Page 202
Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 202 of 232...
Page 203
Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 203 of 232...
Page 204
Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 204 of 232...
12.9. Sample Pump, Speck pump with Gast air motor Please contact Brannstrom Sweden AB to receive the ATEX certificate of the Speck sample pump with Gast air motor. Email: info@brannstrom.se Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 228 of 232...
13. Appendix, Work shop test and Calibration Certificate The 4 following pages contains: Work shop test: 4 pages Calibration Certificate: 1 page Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 229 of 232...
Page 230
This page is intentionally left blank. Brannstrom Sweden AB CleanTrack 1000B - Rev 2.20xd, 2019 Page 230 of 232...