OPERATION MANUAL
CLEAN ROOM INDICATOR
(TEMP., HUMIDITY, P INDICATOR)
Model No. : UT-1406
Website:
Δ
COM.
Uni
Uni
versal
versal
Tech
Tech
nology
nology
Ph
:
+91 7046223333
www.utplindia.in
z
E-mail :
sales@utplindia.in

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UT-1406 and is the answer not in the manual?

Questions and answers

Summary of Contents for Unitech UT-1406

  • Page 1 Model No. : UT-1406 OPERATION MANUAL CLEAN ROOM INDICATOR (TEMP., HUMIDITY, P INDICATOR) Δ Model No. : UT-1406 COM. Sure for service with hi-end Sure for service with hi-end versal versal Tech Tech nology nology Add.-78/1/Z/3, Makarpura GIDC, Makarpura, Vadodara...
  • Page 2 ERROR MESSAGE AND TROUBLESHOOTING COMMUNICATION PROTOCOL INTRODUCTION Unitech Instrument’s Clean Room Indicator is designed to display Temperature, Humidity and Room Pressure Difference in one unit. These instrument accepts inputs from standard T + RH sensor or internal sensor. The instrument displays the temperature (ºC) in the range of 0 to 100ºC and humidity in the range of 0.0 to 100.0 % RH...
  • Page 3: Front Panel Description

    Model No. : UT-1406 PAGE : 2 FRONT PANEL DESCRIPTION ºC High High High DISPLAY DESCRIPTION Seven Segment LED displays of Temp, Rh and Diff. Press. Red LED will glow on low Process values of ºC,%Rh, or P Δ High Red LED will glow on high Process values of ºC,%Rh, or P...
  • Page 4: Technical Specification

    Model No. : UT-1406 PAGE : 3 TECHNICAL SPECIFICATION FDA 21 CFR part 11 - GAMP-4 compatible. Microcontroller based indicator with inbuilt Temperature, RH & DP measurement in single enclosure. All channel are programmable ranges and unit.(Through Front key pad).
  • Page 5: Installation

    Model No. : UT-1406 PAGE : 4 INSTALLATION Terminal Detail T + rH SENSOR RS-485 24VDC CAUTION WIRING CONSIDERATION SHIELDED TWISTED PAIR WIRE IS USED FOR ALL ANALOG I/P, PROCESS SENSORS, RTD, THERMOCOUPLE, DC mV-mA, VOLT DC, LINEAR INPUT AND COMMUNICATION...
  • Page 6: Programming Flow Chart

    Model No. : UT-1406 PAGE : 5 PROGRAMMING FLOW CHART Configuration Setup Change Mode Calibration Selection Mode Mode Mode Password Press Press Press Press Press new - Sure for service with hi-end Sure for service with hi-end versal versal Tech...
  • Page 7: Configuration Mode

    Model No. : UT-1406 PAGE : 6 CONFIGURATION MODE CONFIGURATION MODE PARAMETER Description Range Parameter Default Value Password for Parameter Setting Scroll the digit by key, increase by 000 to 999 Values between Password for Configuration Parameter Temperature Alarm-1 type...
  • Page 8: Setup Mode

    Model No. : UT-1406 PAGE : 7 Description Range Parameter Default Value RH Damping Change the value by key or key. 00 to 10 Values between Note: Factory set Value Pressure Damping Change the value by key or key. 00 to 10...
  • Page 9: Calibration Mode

    Model No. : UT-1406 PAGE : 8 Range Description Parameter Default Value Pressure Diff Alarm 1 Set point 000 to 999 Values between Scroll the digit by key, increase by Set point for buzzer activation. Pressure Diff Alarm 2 Set point...
  • Page 10: Error Message And Troubleshooting

    Model No. : UT-1406 PAGE : 10 CHANGE PASSWORD MODE Description Range Parameter Default Value Old Password. Scroll the digit by key, increase by key. Values between 000 to 999 Existing Password New Password. Scroll the digit by key, increase by key.
  • Page 11: Node Address

    Model No. : UT-1406 PAGE : 11 REGISTER ADDRESS FOR MODBUS RTU PROTOCOL SR NO PARAMETERS ABSOLUTE ADDRESS ACCESS TYPE TEMPERATURE VALUE 40001 READ ONLY HUMIDITY VALUE 40002 READ ONLY DIFF. PRESS. VALUE 40003 READ ONLY SETPOINT 1 LOW 40004...