Newlec NL5701B Instructions
Newlec NL5701B Instructions

Newlec NL5701B Instructions

Occupancy detector-ceiling mounted

Advertisement

CEILING MOUNT(PIR)TIMER
PRODUCT: NL5701B THREE WIRE
RATING AT 240V AC 50Hz
• All load types 10A • Time Delay 2min - 1h • Sensitivity Adjustment
Removable
• Test Mode
• Auto and Manual Lux Sensor for Daylight Control
Fascia
The Ceiling Mount PIR comes with surface and flush mounted options. It
also has interchangeable white and chrome fascias.

USAGE

KEY FEATURES

The PIR sensor has been designed to switch lighting, heating and ventilation
loads up to 10A. The unit is switched on by the detection of moving infra red
Rating at 240V AC 50Hz
heat within a specified range. When infra red heat, such as a moving body, is no
All load types 10A
longer detected, the unit will switch off the load after the adjustable time period
has elapsed. If infra red heat is detected again during the timing period, the
Time Delay 2min - 1h
timing sequence will restart. The unit has a lux level adjustment and Auto Lux
Sensitivity Adjustment
function, which measures the ambient light levels and prevents lighting being switched on, when there is sufficient lighting in the room.
Test Mode
There is a sensitivity adjustment and test mode function added for your convenience.
Auto and Manual Lux Sensor for Daylight Control
A POWER FACTOR CORRECTION CAPACITOR OF 4 MICROFARADS WILL OFTEN BE REQUIRED WHEN SWITCHING LOW WATTAGE LOADS, e.g.
LED LOADS. THE CAPACITOR IS FITTED ACROSS SWITCH LIVE AND NEUTRAL SUPPLIES OF SUITABLE NEWLEC CAPACITORS CAN BE FOUND AT YOUR
STOCKIST (REF NL5705A). DO NOT INSULATION RESISTANCE TEST THIS PRODUCT. REMOVE BEFORE TESTING OR TEST CIRCUIT PRIOR TO FITTING.
DO NOT INSULATION RESISTANCE TEST THIS PRODUCT. REMOVE BEFORE TESTING OR TEST CIRCUIT PRIOR TO FITTING
CAREFUL POSITIONING IS ESSENTIAL TO OBTAIN OPTIMUM PERFORMANCE
TECHNICAL DETAILS
CAREFUL POSITIONING IS ESSENTIAL TO OBTAIN
OPTIMUM PERFORMANCE.
Use the detection range to determine a suitable location for the sensor. When locating the position of the units, ensure the sensor is
not subjected to bright or direct sunlight or in areas with high reflective surfaces. Do not site units on a vibrating surface, or near forced
Use the detection range to determine a suitable location for
air heating and ventilation. They should not be placed within 1 metre of the load. Sensors work when objects move across their field of
the sensor. When locating the position of the units, ensure the
sensor is not subjected to bright or direct sunlight or in
view. Position the sensor where people will be detected walking across the zones rather than towards the zones identifiedin Diagram 1.
Removing the Sensor from
areas with high reflective surfaces. Do not site units on a
Adjust sensitivity to suit the area that the sensor has been installed in.
Surface Mount Box
Diagram 1
Squeeze
the housing
on either side as shown here
7 metres approx.
IMPORTANT NOTICE
IMPORTANT NOTICE
All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE Wiring regulations BS7671.
All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE 17th Edition Wiring regulations
BS7671:2008. The circuit should be isolated before carrying out any work. Failure to adhere to the instructions will invalidate the warranty.
The circuit should be isolated before carrying out any work. Failure to adhere to the instructions will invalidate the warranty.
Newlec Helpline: 0845 123 6539
Newlec Helpline: 0800 783 6909
Instructions
CEILING MOUNT (PIR)TIMER
Surface
Mount
Box
DIAGRAM 1
CEILING
FLOOR
PRODUCT RANGE
OCCUPANCY DETECTOR -
CEILING MOUNTED
PART NUMBER
NL5701B THREE WIRE
USAGE
The Occupancy Detector sensor has been designed to switch
lighting, heating and ventilation loads up to 10A. The unit is
switched on by the detection of moving infra red heat within a
specified range. When infra red heat, such as a moving body,
is no longer detected, the unit will switch off the load after the
adjustable time period has elapsed. If infra red heat is detected
again during the timing period, the timing sequence will restart.
The unit has a lux level adjustment and Auto Lux function, which
measures the ambient light levels and prevents lighting being
switched on, when there is sufficient lighting in the room. There
is a sensitivity adjustment and test mode function added for your
convenience.
The Ceiling Mount Occupancy Detector comes with surface and
Removable
flush mounted options. It also has interchangeable white and
chrome fascias.
A power factor correction capacitor of 4 microfarads will often be
required when NewlecNL5705A switching low wattage loads, e.g.
LED loads. The capacitor is fitted across switch live and neutral.
vibrating surface, or near forced air heating and ventilation.
They should not be placed within 1 metre of the load.
Sensors work when objects move across their field of view.
Position the sensor where people will be detected walking
across the zones rather than towards the zones identified
in Diagram 1. Adjust sensitivity to suit the area that the sensor
has been installed in.
Removing the Sensor from
Surface Mount Box
Squeeze
the housing
on either side as shown here
Instructions
Instructions
Surface
Mount
Box
Fascia
RPM377
RPM 377

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NL5701B and is the answer not in the manual?

Questions and answers

Summary of Contents for Newlec NL5701B

  • Page 1 1 metre of the load. LED LOADS. THE CAPACITOR IS FITTED ACROSS SWITCH LIVE AND NEUTRAL SUPPLIES OF SUITABLE NEWLEC CAPACITORS CAN BE FOUND AT YOUR STOCKIST (REF NL5705A). DO NOT INSULATION RESISTANCE TEST THIS PRODUCT. REMOVE BEFORE TESTING OR TEST CIRCUIT PRIOR TO FITTING.
  • Page 2 Occupancy Detector to switch day and night. All the way to the minus sets the timer to ZERO lux and effeftively switches off the Occupancy Detector. To set manually you will need to be present at dusk. (See Diagram 3). Newlec Helpline: 0845 123 6539 IMPORTANT NOTICE All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE Wiring regulations BS7671.
  • Page 3 All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE Wiring regulations BS7671. The circuit should be isolated before carrying out any work. Failure to adhere to the instructions will invalidate the warranty. Newlec Helpline: 0800 783 6909 RPM 377...
  • Page 4 All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE Wiring regulations BS7671. The circuit should be isolated before carrying out any work. Failure to adhere to the instructions will invalidate the warranty. Newlec Helpline: 0800 783 6909 Manufacturers Address: Newey & Eyre Eagle Court 2, Hatchford Way, Birmingham B26 3RZ...