Error code
E1x
E10 (drY)
E11
E2x
E22 (hot)
E23
E24
E25
E26
E27
E3x
E31
E4x
E40
E42 (LEd)
E43 (con)
E44
E45
E46
E47
E48
E49
E5x
E51
E52
E53
Description
Load errors
Low motor load
High motor load
Protection active
Converter temperature limit
Converter temperature protection
Converter overcurrent
Overvoltage
Undervoltage
PFC Overcurrent
Pump errors
Software motor protection active.
Device specific error codes
General frequency converter error
LED faulty
Communications failed
DC link current offset
Motor temperature outside limits
Circuit temperature outside limits
Voltage reference outside limits.
15V outside limits
Test load does not match
Motor error codes
Motor parameters out of range
Thermal protection active
Invalid model selected
Probable cause
Low load detected. Pump is running dry.
Motor might be faulty or viscous medium is
present.
Circuit is too hot and power was reduced to
less than 2/3 of rated power.
Circuit is too hot to run, pump stopped
Hardware overcurrent protection triggered.
Line voltage is too high
Line voltage is too low for proper operation.
Power correction circuit current cannot be
controlled
Average motor current was too high, pump
load is much higher than expected
Electrical circuitry did not pass self‐test.
One of the display segment diodes is faulty
(open/short)
Display board does not detect proper
connection to main board, but power supply
is present
Voltage on DC link shunt (R34) not in
expected range
During MFG. TEST, this is 10 kΩ, 1% resistor
for 10 °C..30 °C During operation, expected
values are ‐55 °C..150 °C
During MFG. TEST, this is 0 °C..50 °C. During
operation, expected values are ‐55 °C..150
°C
Comparison between internal references
does not match
15V supply is not 15V.
No test load detected or current
measurement does not work properly (MFG.
TEST)
Motor does not behave as expected
Motor temperature is too hot to operate.
Pump model not valid or out of reach
20