Bionix Aquabot OtoClear 7270 Instructions For Use Manual

Bionix Aquabot OtoClear 7270 Instructions For Use Manual

Ear irrigation kit
Hide thumbs Also See for Aquabot OtoClear 7270:

Advertisement

OtoClear
Powered by Aquabot
®
®
Ear Irrigation Kit
INSTRUCTIONS FOR USE
PRODUCT OFFERING
#7270 - OtoClear/Aquabot, 20 tips, 1 Ear Basin
#7275 - OtoClear/Aquabot, 5 tips, 1 Ear Basin
INNOVATIVE SOLUTIONS FOR EVERYDAY PROBLEMS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aquabot OtoClear 7270 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bionix Aquabot OtoClear 7270

  • Page 1 OtoClear Powered by Aquabot ® ® Ear Irrigation Kit INSTRUCTIONS FOR USE PRODUCT OFFERING #7270 - OtoClear/Aquabot, 20 tips, 1 Ear Basin #7275 - OtoClear/Aquabot, 5 tips, 1 Ear Basin INNOVATIVE SOLUTIONS FOR EVERYDAY PROBLEMS...
  • Page 2 CONTENTS Note: Any other use for the product outside of the intended use stated herein, Bionix shall not be held liable. Getting Started: Getting Started ......Unpacking and Verifying Contents: Before continuing, inspect the package for any damage during shipping.
  • Page 3 Aquabot PARTS ID Aquabot WARNINGS ® ® • Do not over-pressurize the unit. Pump Handle • Do not use liquids with temperatures above Trigger F / 49 • CHOKING HAZARD Unit contains small parts. Spring Not suitable for children under 3 years. Pinch Tube •...
  • Page 4 OtoClear , powered by Aquabot ® ® Grasp the OtoClear Tip and USE INSTRUCTIONS: twist onto the luer lock fitting of the adapter until it stops. Clean by filling base half full with soapy water, twist on the lid, shake to clean and then Pump no more than 6 times.
  • Page 5 High Level Disinfection of OtoClear ® Aquabot MAINTENANCE ® powered by Aquabot ® It is recommended to high level disinfect OtoClear ® , powered by Aquabot ® after any use where there was contact with blood, infectious material, or • Clean with soap and water as needed. non-intact skin.
  • Page 6 Aquabot TROUBLESHOOTING CHART ® PROBLEM REASON SOLUTION Replacement parts available Lid O-ring is missing at lunatecgear.com Unit does not build Pump Barrel is too loose Tighten Pump Barrel or hold pressure Email Something else support@lunatecgear.com or call 858.653.0401 Remove trigger and unkink Pinch Tube is kinked Pinch Tube Builds pressure but...
  • Page 7 Obelis s.a • Boulevard Général Wahis 53 • 1030 Brussels, BELGIUM Tel: +(32) 2.732.59.54 • Fax: +(32) 2.732.60.03 • E-Mail: mail@obelis.net Bionix Development Corp. • 5154 Enterprise Blvd. Toledo, OH, 43612, U.S.A. Phone: +1 419.727.8421 • Fax: +1 800.455.5678 • www.Bionix.com ©2019 Bionix Development Corp.