INSTALLATION:
Wire the electrical cord into a junction box rated for 110 volts or 220 volts, depending on the electrical
specifications of your unit. see the electrical plate on the shield for specifications.
Do not attempt electrical hookup unless you have the proper tools and are qualified to do so.
SPRING ADJUSTMENT:
Adjustubes are factory set to an average rate. however, you may need to adjust the springs to obtain the
best dispensing rate for your dinnerware.
To Adjust for Rate of Rise
1.
Lift the tube out of the shield.
2.
Place approximately 4 inches of dinnerware into the tube, and note the
height of the dinnerware above the tube.
3.
Load the tube until it is approximately 3/4 full, and again note the height of the
dinnerware above the tube. if the height is the same as in step 1, the rate is correct.
If the height is higher than in step 1, unhook one spring from he bottom of the spring hanger, and repeat
steps 2 and 3. Continue disconnecting springs from the bottom hanger until you find the proper spring
combination for your dinnerware.
NOTE:
It is not necessary to replace the tube in the shield to place the dinnerware on the tube. leave the shield off
until you find the proper adjustment.
NOTE:
Balance color and number of springs on all sides of the tube to provide smoothest operation.
NOTE:
On unheated tubes, yellow springs are stronger than silver ones (yellow are rated at 4 ounces and silver are
rated at 2-1/2 ounces). On heated tubes, black springs, rated at 4 ounces, are stronger than the 2-1/2 ounce
gray springs.
If the height is lower than in step 1,
hook it onto the moveable head. Again try to balance colors and number of springs on all sides of the tube.
Repeat steps 2 and 3 until a consistent dispensing rate is obtained, adding more springs as necessary.
NOTE:
The wire head must be centered about the spring hanger or the mechanism will bind and not move
smoothly to dispense the plates.
TO ADJUST FOR DISPENSING HEIGHT:
Raise or lower the height of the top dish above the tube by connecting or disconnecting springs or replacing
a lighter spring with a stronger one or vice-versa.
TEMPERATURE ADJUSTMENT (HEATED ONLY):
Remove the tube from the shield and adjust the thumbwheel located about 3 inches below the indicator
light. Turn wheel up to raise the temperature and down to decrease it.
!