Shutting down and storing the EFOY fuel cell
7
Shutting down and storing the EFOY fuel cell
7.1 Shutting down the EFOY fuel cell
Switch off the EFOY fuel cell (see S
Remove the EFOY fuel cartridge.
7.2 Storing the EFOY fuel cell
Always carry out the transportation protection procedure prior to storing the EFOY
fuel cell to prevent it from freezing (see S
4.2.4).
ECTION
Unplug the charging cable (1).
Unplug the cable (2) for the
operating panel or Bluetooth
adapter.
Disconnect the exhaust gas hose (1)
and seal the exhaust gas opening
with the protective cap. (See S
2.2)
Disconnect the exhaust heat
elbow (2) and the exhaust heat
tube (3).
Loosen the belt.
Remove the EFOY fuel cell from the
installation space.
7.3).