Do not operate the pump out of water. The pump pick up area must be completely submerged during operation.
8
Do not exceed the maximum submersible depth (see specifications: max. Water depth).
8
Do not operate the pump during freezing temperatures. Do not leave the pump in water that may freeze.
8
Do not use for pumping sea water or inflammable, corrosive, explosive or dangerous liquids.
8
Do not carry the pump by its electrical cable, or its outlet pipe. Use the handle only.
8
Do not leave the pump unattended if the float switch is manually fixed in the 'on' position.
9
When not in use, switch off pump and remove plug from power supply. Rinse pump, drain out any water and store in a frost free, safe
location.
warninG! Do not allow uncontrolled discharge of contaminated water which would pollute the environment.
n.B:- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaninand user
maintenance shall not be made by children without supervision.
2. introDUction
manufactured from corrosion resistant materials with stainless steel motor case and noryl® base cover. Fitted with automatic
cutout. Puddle pump with minimum water depth of just 2mm makes this ideal for flood recovery. Designed for clean water
although these pumps will accept small particles up to 5mm. Suitable for the effective drainage of cellars, sinks, cisterns, baths and
the general transfer of water.
3. speciFication
model no. ........................................................WPl117A
Cut out........................................................... Automatic
outlet od ............................................................. 32mm
maximum output ..................................117ltr(26gal)/min
maximum Head .......................................................8mtr
maximum Water depth ............................................7mtr
minimum Water depth ........................................... 2mm
maximum Partical Size ........................................... 5mm
motor Power ..........................................................400W
Supply ....................................................................230V
4. operation
warninG! ensure you read, understand and apply safety instructions.
4.1.
Fit an appropriate discharge pipe to pump outlet and secure with a clip. ensure the diameter of the discharge pipe is the same as or
greater than the outlet diameter, as a smaller pipe will adversely effect the pump flow rate.
4.2.
Position the pump in the water accordingly, and place the outlet pipe securely in the discharge receptacle or area. It is recommended
that the pump is sunk with its discharge outlet facing up, to release any trapped air.
4.3.
Connect the pump to the electrical mains supply and switch it on.
4.4.
UsinG as a conventional sUbmersible pUmp: The pump will turn on automatically as the level of water rises (fig.1.A). As
the water level lowers, the float will switch the pump off automatically as it reaches the minimum height (fig.1.B). The float may be
adjusted by shortening or lengthening the cable (fig.2). The pump will switch on if the water level is up to or above the maximum length
of the float cable. To function correctly the float must move freely. ensure the float can do so and that the cable is not restricted. Check
that the pump and discharge are working correctly.
fig.1
4.5.
UsinG as a pUDDle pUmp: In order to draw water from a shallow depth, the float switch needs to be immobiled as in fig.3. In
this mode the pump will not function automatically so, consequently, must be not be left unattended owing to the risk of overheating.
The normal medium for cooling the pump motor is the water in which it is submerged, therefore excessive use in the open air carries
the risk of damage.
5. maintenance
warninG! With the exceptions listed below, all pump, float and electrical cable service maintenance and repair must only be
undertaken by an authorised service agent. Failure to observe this rule may be dangerous and will invalidate the warranty.
warninG! ensure the pump is disconnected from the mains power supply before attempting any service or maintenance.
5.1.
Keep all parts of the pump clean. Rinse, drain and allow to dry before storing the pump.
© Jack Sealey limited
fig.2
Original Language Version
fig.3
WPl117A | Issue 3(H) 20/03/18

Advertisement

loading