5. Keep all original packaging material for future storage or warranty shipments of the board. Caution Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by SBS Technologies. Dispose of used batteries according to the instructions of SBS Technologies. Vorsicht! Explosionsgefahr bei unsachgemäßem Austausch der Batterie.
SBS Technologies do not accept any liability concerning the use of their products in life support systems. Warranty SBS Technologies grants the original purchaser of SBS Technologies products a warranty of 12 month from the date of delivery.
2.9 Register Set ...........................33 2.9.1 Standard Register Set ......................34 2.9.2 Extended Register Set ......................34 2.10 Interrupts ...........................35 2.11 DMA ............................35 Function Blocks ..........................36 3.1 EIDE/ATAPI Interface........................36 3.2 Serial Interfaces..........................36 SBS Technologies – CR7 Hardware User’s Manual V 1.3 Page 5 of 51...
Page 7
3.10.1.2 Serial EEPROM ......................46 3.10.2 Watchdog, Powerfail Monitor...................46 3.10.3 LED Output........................47 3.10.4 NMI Timer ........................47 3.10.5 Reset Button ........................47 3.10.6 Speaker..........................47 Appendix ..............................48 Software Guide .............................48 Error Report Form ..........................49 SBS Technologies – CR7 Hardware User’s Manual V 1.3 Page 6 of 51...
100BaseTX interface and integrated FIFO buffer • SCSI PCI Wide SCSI-2 controller (SYM53C875) with up to 40 Mbytes/s transfer rate • Floppy Supported formats: 3.5 inch, 720 Kbyte - 1.44 Mbyte SBS Technologies – CR7 Hardware User’s Manual V 1.3 Page 7 of 51...
Page 9
1 °C increments from -55 to +125 °C, • H110 Backplanes When using the CR7 in backplanes providing H110 functionality at the CPCI-J4 connector, a optional version the CR7T is available, which is exactly the version CR7P but without the CPCI-J4 rear connector.
The table below helps customers calculate the power consumption of each CR7 system. For measurement, the CR7 is mounted on a CPCI backplane, without keyboard and hard disk. The operating system (MSDOS) comes up from floppy disk. During measurement, the power consumption of the backplane and the floppy drive can be ignored.
Page 11
• Onboard Lithium Battery C,I,F,G style: CR2450, estimated life time >=10 years (45°C) • External Battery Input K,R,N style: input range 2.7 – 4.5 V, max. current (3.0V) 2uA SBS Technologies – CR7 Hardware User’s Manual V 1.3 Page 10 of 51...
Page 12
02/26/2001 PS 30,0 Airspeed m/s 0 m/s airflow means convection cooled only; the highest operating temperature for the CR7 board is always +70°C The core temperature of the CPU can be read out via the onboard temperature sensor and the value must keep to the limits from the table below under all operating conditions.
Page 13
Environment C,I,F,G,E,R-Style K,N-Style Vibration Spectrum 5 to 200 Hz 5 to 2000 Hz Acceleration Shock Amplitude 40g/100g Duration 11ms/6ms SBS Technologies – CR7 Hardware User’s Manual V 1.3 Page 12 of 51...
2 Hardware Installation The CR7 is a fully IBM-AT compatible stand-alone PC. It is equipped with all functions a conventional Personal Computer can only offer with several add-on cards . Extension boards can be connected via the CPCI interface. The minimized board size and the large number of interfaces and functions enable the CR7 for use in many applications.
For easy connection of the I/O signals to standard connectors, a transition module CTM6 is available from SBS Technologies. The Wide SCSI connector is populated only on the version CTM7. Additional Power should be provided to the CTM6 via P18/P17 for better supply of the IDE. The +12V to P19 are not required when used with a CR7.
CPCI connector reference: The CPCI specification numbers the CPCI connectors from bottom to top J1, J2, J3, J4, J5. The CPCI connectors on the CR7 are P7201, P7202, P7203, P7204, P7205 respectively. SBS Technologies – CR7 Hardware User’s Manual V 1.3...
2.7.2 I/O Connector (P7204, P7205) The connector P7204 carries the signals for the I/O signals of the CR7. For easy connection to standard connectors, a transition module CTM6 or CTM6A is available from SBS Technologies. P7204 L2_SLCT L2_D7 HD_D8 \HD_RST...
2.7.3 I/O Connector2 (P7203) The connector P7203 carries the signals for the PMC-I/O and MIL 1553 signals of the CR7 +5V * PMCIO_64 PMCIO_63 PMCIO_62 PMCIO_61 PMCIO_60 PMCIO_59 PMCIO_58 PMCIO_57 PMCIO_56 PMCIO_55 PMCIO_54 PMCIO_53 PMCIO_52 PMCIO_51 PMCIO_50 PMCIO_49 PMCIO_48 PMCIO_47...
Please note that the IDE connector at CTM6A is a 40 pin header with 2.54mm spacing. Therefor external power has to be supplied to the IDE drive. For attaching a 2.5" harddisk, a transition module HD-ADAP1B is available from SBS Technologies. SBS Technologies – CR7 Hardware User’s Manual V 1.3 Page 23 of 51...
2.7.5 Keyboard/PS-2 Mouse Interface (P2000, CTM6-P15, CTM6A-P27) The CR7 allows an easy adaptation of a keyboard to a standard 6-pin MINI-DIN connector. Also a PS/2 mouse can be connected via a external cable splitter. Name P2000 CTM6-P15 CTM6A-P27 Keyb. Data...
2.7.8 Serial Interfaces (P2200, CTM6-P5, 8, 11, 10, CTM6A-P16, P23, P26, P17) The CR7 offers four serial ports, two of them are optional (COM3 and COM4). COM1 and COM2 have socketed line drivers configured for RS232 and can be reconfigured for RS422 by the user (Please check the section Socket Installation above).
One USB channel is available at the front panel and both can be connected at the CTM6. Name P1700 CTM6-P15 CTM6A-P27 Fused +5V +5V unfused USB1- USB1+ USB2- USB2+ SBS Technologies – CR7 Hardware User’s Manual V 1.3 Page 26 of 51...
Name CTM6-P9 Name CTM6A-P11 COM2-TXD COM2-RXD KBCLK KBDAT enableVCC enableVEE BACKL VSYNC HSYNC 2.7.13 Flat Panel Display connector (CTM6A-P14) This connector is not supported with the CR7. SBS Technologies – CR7 Hardware User’s Manual V 1.3 Page 28 of 51...
The onboard 1553 interface can be connected at the transition module CTM6B via P10 Name CTM6B-P10 Name SHORT1A+ SHORT1A- LONG1A+ LONG1A- CENTERA CENTERB LONG1B+ LONG1B- SHORT1B+ SHORT1B- SBS Technologies – CR7 Hardware User’s Manual V 1.3 Page 30 of 51...
The connector P20 at the CTM6B is not counted normal, but counted like a D-SUB shell, first the row starting at Pin 1 to Pin 34, then the second row from Pin 35 to Pin 68. SBS Technologies – CR7 Hardware User’s Manual V 1.3 Page 31 of 51...
P3 (Ethernet connector) pin 14. The corresponding ground is at P3 pin 13. VIO is the I/O voltage of the PMC slot and is connected on the CR7 to +5V SBS Technologies – CR7 Hardware User’s Manual V 1.3...
System BIOS 2.9 Register Set The following chapter provides an overview of the registers located in the I/O address area of the CR7. The address location of PCI devices such as SCSI or Ethernet are not described in the following tables because the System BIOS automatically configures (PnP, Plug and Play) each PCI device to avoid address conflicts.
These I/O addresses are used by optional devices. 2.9.2 Extended Register Set The extended register set is specific to the CR7. To protect the system against illegal register accesses, the extended register set can be locked by using the LOCKR register.
The interrupt routing for standard components such as COM1/2, LPT1, ... is in compliance with standard PC/AT systems. Unused interrupts can be used for add-on cards or other board specific PCI devices such as SCSI and Ethernet. The CR7 BIOS setup allows manual routing for the PCI devices. Hardware IRQ...
3.2 Serial Interfaces The CR7 serial ports are fully compatible with the NS16450 and NS16550. This means that each serial interface provides a 16 byte FIFO and therefore offers a higher performance than earlier used standard serial interfaces. The UARTs have programmable baud rate generators capable of 50 to 115200 baud.
1280x1024 78.75 43(I) 1600x1200 162/2 (I) denotes interlaced video display Flat panel only 3.5.2 Supported Panel Types The following displays have been tested successfully with the CR7. Manufacturer Part Number Resolution Technology Panel Drive Interface NL6448AC33-18 640x480 18 Bit Sharp...
Since the Intel/Chips&Technologies 69000 is used on a large number of computers, many operating systems like OS/2 ,Windows NT, Windows 95 and Windows 98 already include high resolution drivers. 3.6 PMC Slot The following table describes the compatibility between PMC (PCI mezzanine cards) and the CR7. Air cooled Air cooled...
(68-pin for wide SCSI) from the SCSI host adapter to the peripheral devices is needed. The SCSI interface on the CR7 is a host interface, consisting of the PCI Bus SCSI controller Symbios 53C875. This controller chip drives the SCSI protocol in accordance to the ANSI X3.131-1986 (SCSI-1) and ANSI X3.131-199x (SCSI-2) specification, with the following functions:...
CD-ROM peripherals for the DOS, Windows 3.xx, Windows95/98/NT, OS/2 and Novell 3.x, 4.x and various UNIX environments. The floppy disks or CDROM supplied with the CR7 include the most commonly used software drivers and utilities. More software is available from the Internet. For detailed information please refer to the Appendix chapter 'Update Information' of this manual.
For registration and identification of a workstation in a LAN, a unique ID number is required. Each network card is assigned a unique ID number, which resides in an Ethernet address ROM on the CR7. An Ethernet boot option can be enabled in BIOS setup.
3.9.1 1553 Control Registers Two I/O addresses are used to enable and initialize the 1553 interface into the CR7 memory map. I/O write to address 16Ch buffers the RT-address into the 1553 controller and a write to I/O address 16Dh defines the memory area of the 1553 RAM and registers.
RT BIT Word Register (RD) Test Mode Register 0 Test Mode Register 1 Test Mode Register 2 … … Test Mode Register 7 Reserved … … Reserved SBS Technologies – CR7 Hardware User’s Manual V 1.3 Page 44 of 51...
The 1553 transformers provide long and short stub terminals, these terminals are available the rear connector. If the transition module CTM6A is connected to the CR7, the 1553 signals are routed to the Header P10 as described in the section Connectors. For more information please see the sketch below.
3.10.1.2 Serial EEPROM For storage of user data a serial EEPROM is implemented on the CR7 board. It is a standard 24C04 type EEPROM with 512 bytes. Please note that some operating systems may use the lower 256 bytes of this device for their own purposes.
SBS onboard I/O'. 3.10.4 NMI Timer The CR7 features a timer which can trigger NMIs periodically. The timer is programmable in 7 steps from 0.28 ms up to 18 ms. The usage of the NMI timer is possible together with appropriate software available from your distributor, Windows 3.11, Windows 95 and Windows NT offer "Real Time...
VGA/LCD(Intel) System BIOS www.sbs.com The CDROM contains a utility program for system BIOS updates. The CR7 is equipped with an in- system programmable FLASH ROM device. • Additional Software Tools SBS Technologies provides a full set of DLLs (MSDOS, Windows 3.11, Windows 95, Windows NT) for their PC boards.
Page 51
Error Report Form Company Name SBS Technologies GmbH & Co.KG Department Memminger Str. 14 Contact Person 86159 Augsburg Mailing Address Phone Number Phone Number +49 821 5034-116 Fax Number Fax Number +49 821 5034-119 Email Address _ . _ __ __ __ ___________ Part.
Page 52
Error Report Form (US + Rest of World) Company Name SBS Technologies, Inc. Department 6301 Chapel Hill Road Contact Person Raleigh, NC 27607-5115 Mailing Address Phone Number Phone Number +1 919 851-1101 Fax Number Fax Number +1 919 851-2844 Email Address _ .
Need help?
Do you have a question about the CR7 and is the answer not in the manual?