Falcon PLUS E3407 Installation And Servicing Instructions

Dominator bain marie
Hide thumbs Also See for PLUS E3407:

Advertisement

Quick Links

DOMINATOR PLUS E3407 BAIN MARIE
INSTALLATION and
SERVICING INSTRUCTIONS
Caution : Read the instructions before
using this appliance.
IMPORTANT
The installer must ensure that the installation of the appliance is in conformity with these instructions and National
Regulations in force at the time of installation. Particular attention MUST be paid to –
BS7671 IEE Wiring Regulations
Electricity at Work Regulations
Health And Safety At Work Act
Fire Precautions Act
This appliance has been CE-marked on the basis of compliance with the Low Voltage and EMC Directives for the
voltages stated on the Data Plate
WARNING -THIS APPLIANCE MUST BE EARTHED
On completion of the installation these instructions should be left with the Engineer-in-Charge for reference during
servicing. Further to this, The Users Instructions should be handed over to the User, having had a demonstration of
the operation and cleaning of the appliance.
IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING
THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED
FOR A SERVICE CALL.
PREVENTATIVE MAINTENANCE CONTRACT
In order to obtain maximum performance from this unit we would recommend that a Maintenance Contract be
arranged with SERVICELINE. Visits may then be made at agreed intervals to carry out adjustments and repairs. A
quotation will be given upon request to the contact numbers below.
WEEE Directive Registration No. WEE/DC0059TT/PRO At end of unit life, dispose of appliance and
any replacement parts in a safe manner, via a licenced waste handler.
units are designed to be dismantled easily and recycling of all material is encouraged whenever
practicable.
Falcon Foodservice Equipment
HEAD OFFICE AND WORKS
Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.
SERVICELINE CONTACT
Phone: 01438 363 000
Fax: 01438 369 900
T100819 Ref.4

Advertisement

Table of Contents
loading

Summary of Contents for Falcon PLUS E3407

  • Page 1 DOMINATOR PLUS E3407 BAIN MARIE INSTALLATION and SERVICING INSTRUCTIONS Caution : Read the instructions before using this appliance. IMPORTANT The installer must ensure that the installation of the appliance is in conformity with these instructions and National Regulations in force at the time of installation. Particular attention MUST be paid to –...
  • Page 2 IMPORTANT INFORMATION Warranty Policy Shortlist: Warranty does not cover :- Correcting faults caused by incorrect installation of a product. Where an engineer cannot gain access to a site or a product. Repeat commission visits. Replacement of any parts where damage has been caused by misuse. Engineer waiting time will be chargeable.
  • Page 3: Section 1 - Installation

    The unit should be installed on a table or similar surface. Alternatively, it may be installed upon a purpose-designed floor-stand, supplied by Falcon. If unit is to be positioned in close proximity to any wall, partition etc., a clearance of 25mm at the rear and sides should be observed.
  • Page 4: Electrical Ratings

    1.5 ELECTRICAL RATINGS Electrical loading is stated below and also on data plate. The location of mains isolating switch should be identified for use in any event of an emergency or during cleaning. E3407 1.5kW A @ 230 V SECTION 2 - ASSEMBLY and COMMISSIONING Note The following information should be read as applicable to the unit being assembled.
  • Page 5: Section 3 - Servicing And Maintenance

    SECTION 3 - SERVICING and MAINTENANCE BEFORE ATTEMPTING ANY MAINTENANCE, DISCONNECT APPLIANCE FROM THE MAINS. When ordering spares, please quote model number, serial number and voltage as detailed on data plate at unit rear. Remove specific parts as detailed below. 3.1 CONTROL PANEL a) Remove fixings from upper flange of panel.
  • Page 6: Safety Thermostat

    3.5 SAFETYTHERMOSTAT a) Remove control panel as detailed in Section 3.1. b) Remove side panels and element box as detailed in Section 3.4. c) Remove thermostat phial from pan base. d) Remove two fixings that secure thermostat to base panel. The safety thermostat can now be removed. e) Upon refitting, ensure insulating sleeve covers the entire length of capillary tube SECTION 4 - SPARES and ACCESSORIES...
  • Page 7: Circuit Diagram

    CIRCUIT DIAGRAM Safety Stat Operating Stat Red Neon Amber Neon To Control Panel Tag...
  • Page 8: Wiring Diagram

    WIRING DIAGRAM TERMINAL BLOCK ELEMENT RED NEON SAFETY STAT OPERATING STAT AMBER NEON...